Read these instructions before commencing installation. Please give these instructions to the owner/occupier after installation to retain for future reference/maintainence.
Important Information
It is recommended that these luminaires are installed and fitted by a
qualified electrician ensuring the installationcomplies with current IEE
wiring regulations & local building control. These products are designed for
connection toa 240V~50Hz supply.
Any faulty, broken or damaged luminaires should be replaced immediately.
KSR will not accept responsibility for any claims arising from a poor
installation. Please Note: The limited warranty shall be deemed null and void
in the following circumstances: Failure by the installer, end user or any
third party to exercise caution to protect any covered product or part from
outside damage, adverse temperature (normal operating ambient temperature -20
– 40°C), humidity conditions, fluctuations in the electrical system or
physical abuse as well as failure related to workmanship in the installation
of the products or parts.
Important User Advice
Always switch off mains supply before fitting or servicing.
This luminaire is suitable for indoor use only and should not be fitted to
damp or wet surfaces such as freshly plastered or painted surfaces.
Do not use Megger or similar high voltage instruments. Due to the fact this
luminaire contains electronic components that maybe damaged by high test
voltages, they must be disconnected from the circuit before testing. To
prevent damage to the luminaire, do not mix with conventional magnetic
ballasts on the same electrical circuit. At the end of life the luminaire is
classed as WEEE under directive 2014/30/EU and should be disposed of in
accordance with local legislation.
Installation Procedure
Isolate Mains before Installation
Eye Hook Suspension Option
Using the Suspension Eye hook provided and suitable suspension method, ensure
screw lock on eye hook is fully tightened before proceeding to wire luminaire
to mains. Connect mains supply cable to Mains Supply (L,E,N) Turn on Mains and
Test Luminaire
Surface Mounting Bracket (KSR98208) Option
For Mounting Bracket option using fixings provided to secure the bracket to
the high bay, ensure fixings are fully tightened before mounting onto mounting
surface. When bracket is secure proceed to wire luminaire to mains. Connect
mains supply cable to Mains Supply (L,E,N)
Turn on Mains and Test Luminaire.
If using optional KSR98203 sensor accessory please turn over for installation and operation instruction using the KSR98204 Remote Programmer.
Please note : Depending on the amount of LED fittings on a circuit you may have to This product contains a light source of energy efficiency class D upgrade the breaker to a ‘C’ or ‘D’ type due to the way electronic LED drivers start up with higher inrush currents compared to HID lighting.
Dimensions
Lamp
Lamp Details
Product Code| Description| Dimensions L x H| Wattage| Colour| Lumens
KSR98200| Navara HBX 100w| 260mm DIA x 109mm| 100W| 4000K| 12910
The light source of this luminaire is not replaceable; when the light source
reaches its end of life the light source and control gear shall be replaced
This product contains a light source of energy efficiency class D
Instructions
Please note mains must be isolated before sensor is installed
- Fit Sensor by lining up locking Pins into socket on High bay and twist clockwise to lock onto Highbay
Sensor Specification
Operating Voltage | 12VDC |
---|---|
Control Method | 1-10V |
Sensitivity | 10%/50%/75%/100% |
Hold-time | 2s/30s/1min/5min/10min |
Stand-by time | 0s/10s/1min/10min/30min/Infinity |
Stand-by dim level | 10%/20%/30% |
Daylight Sensor | 2~50lux, Disable |
Microwave Frequency | 5.8 GHz +/- 75MHz |
Transmitting Power | <1mW |
Stand-by Power | <0.3W |
Detection Range | Max Installation Height 15mMax Detection Range Ø20m @ 8m |
Detection Angle | 30°~150° |
Work Temperature | -20°~+60°C |
IP Rating | IP65 |
Microwave sensors will detect movement through certain materials, if thisoccurs reduce the detection area until any nuisance triggering stops
Ceiling Mounting (m)
Height (m)
- High Sensitivity Area
- Low Sensitivity Area
Height (m)
- High Sensitivity Area
- Low Sensitivity Area
Permanent On/Off function
This button turns the Light ON or OFF and disables the sensor. To change this
setting Press ‘Auto Mode’, ‘RESET’ or ‘Scene Mode
Auto Mode
Pressing this button activates the sensor and reverts all settings to those
selected before the light was switched ON/OFF
Reset Function
By pressing the RESET button, all settings made with the remote are removed
Dim +/-
Press and hold + or – to adjust the brightness between 10% and 100% during the
Standby Period
Test Mode
Press this button to enter Test Mode. In test Mode Hold time is reduced to 2
seconds. The Stand-by Period and Daylight Sensor is disabled. Exit Test Mode
by pressing ‘RESET’ or any ‘Scene mode’ or ‘Hold Time’ Button.
Detection Range
Press this button to reduce sensitivity
Standby Dimming Level
Use these buttons to set your desired dimming level during the Standby period
Hold Time (Hold Period)
Use these buttons to set the duration of the Hold Period
Remote Control
Standby Period
Use these buttons to set the duration of the StandbyPeriod
Power Output
These button switches output of the luminaire between 80% and 100%. This makes
it possible to conserve power in rooms or areas where 80%%output is sufficient
Lux Control
Use these buttons to set your desired threshold for the daylight sensor
function. When the ambient level of natural light is less than your selected
level, the fitting will turn ON.
Lux Disable
Press this button to disable the built-in daylight sensor. Once disabled, the
sensor will activate the light when someone is present, regardless of the
amount of ambient light.
Daylight Sensor Threshold
Press this button to set the lux value currently measured by the sensor as the
new threshold for the daylight sensor. This replaces the previous setting. If
the amount of ambient light exceeds this threshold, the luminaire will not
turn ON
Scene Mode
For SC1-SC4 you can choose between these alternative settings
Detection Range| Hold Time| Standby Period| Standby
Dim Level| Daylight Sensor
---|---|---|---|---
100%| 1 min| 10 min| 10%| 2 Lux
100%| 5 min| 10 min| 10%| 2 Lux
100%| 10 min| 30 min| 10%| 10Lux
100%| 10 min| | 10%| 50Lux