Specification
Model | ILR-1200-1 |
---|---|
Type | Wireless Bluetooth Rangefinder |
Measuring Range, m | 10 ∼ 1200 |
Accuracy, m | ±1, (10-100 m) |
±(1 + L x 0.25%), (100 < L < 600 m, L being the target distance)
Laser Wavelength, nm| 900 ∼ 908 (Eye-safe)
Laser Pointer, nm| 650
Bluetooth| 5.0
Battery Parameters| One replaceable CR123 / 3.7V / 4h
IP Rating| IP67
Dimensions, mm| 95 x 92 x 85
Weight, g| < 170g (w/o battery)
※ Measurement conditions for typical values: target size =1m x 1m, target reflectance = 85%, outdoor visibility > 5 km
Installation with Mate
- ILR-1200-1 Bluetooth Rangefinder
- Quick release fixture
- Insert ring for TUBE SE series
- L-shaped wrench
- User manual
Product Description
As an accessory of the TUBE series thermal imaging scope (refer to the TUBE user manual for the specific models to work with), ILR-1200-1 Bluetooth Rangefinder enables user to accurately determine the target distance and achieve precise shooting. The device features a compact and light-weighted design, and is built with the visible red dot and movable red dot functions. It supports single ranging and continuous ranging.
Components and Controls
- Bluetooth laser rangfinder module
- Laser indicator
- Laser receive port
- Laser launch port
- Quick release fixture
- Battery compartment cover
- Power button
- LED indicator
LED Indicator
The LED indicator shows the current connection and power status:
Indicator Color | Indicator Status | Device Status |
---|---|---|
Blinking | Automatically searching for a connection | |
Blinking and off | Successfully connected | |
Fast Blinking | Pairing failed | |
Slow Blinking | Low power level |
Battery Installation
- Rotate the battery compartment cover (4) counterclockwise;
- Place a CR123 3.7V battery into the compartment according to the label in the battery compartment, that is, the positive pole faces inward and the negative pole faces outward.
- Tighten the battery compartment cover (4) clockwise.
Safety Instructions
- Use the device within the recommended temperature range from -20°C to +50°C. The battery life may be impaired when using beyond this temperature rang.
- The battery capacity drops when the device is used below Zero. This is normal and does not indicate a defect.
- The device is built with low power shutdown protection: When the battery voltage is lower than 2.8V, the device will automatically shut down with a 30s countdown prompt
Installation with Tube
- Use three inner hexagon screws to connect the bottom of the ILR-1200-1 Bluetooth rangefinder to one end of the fixture (5).
- Clamp the other end of the fixture which is designed as a quick-release clamping ring onto the TUBE series scope.
- The default inner diameter of the clamping ring is 30mm. If installed on the TUBE SE series, a insert ring i s required (included in the package).
Note
When LRF is linked with TUBE, the stadia metric rangefinder function on TUBE
series will be not available.
Linkage and Usage with Tube
- Turn on the Bluetooth function on the Tube.
- Turn on the laser rangefinder with a long press of the Power button (7) for 3s.
- The laser rangefinder module will automatically search and connect with Tube series.
- When the LED indicator (8) on the rangefinder switches from blinking (green) to off, it means the connection is successful.
- Press the Power button (7) twice to turn on or off the laser indicator (2).
- For detailed usage, please refer to the user manual of Tube.
- After use, long press the Power button (7) to power off the rangefinder.
Attention!
Do not point the laser indicator directly to human eyes or faces.
Upgrade
The ILR-1200-1 Bluetooth laser rangefinder supports software upgrade. Users can download the upgrade program from the official website to the mobile device, and upgrade it through the InfOutdoorBC APP.
- Download the upgrade program from the official website.
- Download and install the InfOutdoorBC APP on your mobile device from the APP Store.
- Turn on the Bluetooth of the mobile device.
- Long press the Power button () to turn on the rangefinder.
- Open the InfOutdoorBC APP and tap the Bluetooth icon ( ) in the APP to enter the search interface.
- Tap the Search icon ( ) in the bottom to search the Bluetooth signal.
- Select the name of Infiray-ILR-1200-1 and connect.
- When the connection is successful, an upgrade message is displayed automatically.
- Select Yes to enter the firmware upgrade interface, and tap the Select File option to find and select the upgrade program previously downloaded.
- Tap the Start Upgrade option, then the percentage of the upgrade process will appear on the interface until update successful.
Legal and Regulatory Information
Wireless transmitter module frequency range:
WLAN: 2.412-2.472GHz (For EU)
Wireless transmitter module power < 20dBm (only for EU)
IRay Technology Co., Ltd. thus declares that the Zoom V2 series thermal
imaging monocular complies with the directives 2014/53/EU and 2011/65/EU. The
full text of the EU declaration of conformity as well as additional
information are available at:
www.infirayoutdoor.com.
This device may be operated in all member states of the EU.
User information on the disposal of electrical and electronic devices (private
households)
2012/19/EU (WEEE directive): Products marked with this symbol cannot be
disposed of as unsorted municipal waste in the European Union. For proper
recycling, return this product to your local supplier mums = Upon the purchase
of equivalent new equipment, or dispose of it at designated collection points.
For more information see:
www.recyclethis.info.
Regulatory information USA
FCC ID: 2AYGT-40-ILR
Labeling requirements
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Information to the user
Any Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
Note: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment. Such
modifications could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC RF radiation exposure limits set forth for an
uncontrolled environment.
Body-worn Operation
This device was tested for typical body-support operations. To comply with RF
exposure requirements, a minimum separation distance of 0 cm must be
maintained between the user’s body and the handset, including the antenna.
Third-party belt clips, holsters, and similar accessories used by this device
should not contain any metallic components. Body accessories that do not meet
these requirements may not comply with RF exposure requirements and should be
avoided. Use only the supplied or an approved antenna.
IRay Technology Co., Ltd.
Add.: 11th Guiyang Street, YEDA, Yantai, P.R. China
Tel : 0086-400-999-3800
Email:infirayoutdoor@infiray.com
Web:www.infirayoutdoor.com
Read User Manual Online (PDF format)