DETEX 104200 Lever Trim Instruction Manual

June 4, 2024
DETEX

DETEX 104200 Lever Trim Instruction Manual

Should you have a Question/Problem with your Detex device please call Detex Technical Support from job site at 1-800-729-3839 and choose option 2 on our menu. Please do not return the product to the distributor.

For WARRANTY information, scan code below or go towww.detex.com/warranty

For device installation videos, scan code below or go towww.detex.com/videos
QRcode

LHR ASSEMBLIES SHOW

LHR ASSEMBLIES SHOW

PARTS BREAKDOWN

Item| P/N| QTY| Description
| 106264-7| 1| LEVER ASSY, Q, 626
| 106264-14| LEVER ASSY, Q, 693
| 106264-15| LEVER ASSY, Q, 695
| 101376-7| LEVER ASSY, S, 626
| 101376-14| LEVER ASSY, S, 693
| 101376-15| LEVER ASSY, S, 695
1| 101375-7| LEVER ASSY, U, 626
| 101375-14| LEVER ASSY, U, 693
| 101375-15| LEVER ASSY, U, 695
| 101374-7| LEVER ASSY, T, 626
| 101374-14| LEVER ASSY, T, 693
| 101374-15| LEVER ASSY, T, 695
2| 106603| 2| WASHER, FLAT, 1″x0.02 THK (J LEVER ONLY)
100851| 1| WASHER, FLAT, 1″x0.06 THK (ALL EXCEPT J LEVER)
3| 104210-9| 1| ESCUTCHEON ASSY, BP1, EU, 630 FINISH (BP11 FOR EUV)
4| 100771| 1| STOP, ROTATIONAL
5| PP-5305-108| 1| SCREW, MACH, 10-24 X 1/2 PFH
6| 100777| 4| STANDOFF, HEX
100777-1| STANDOFF, HEX, CVR (V)
7| 100775| 1| WASHER, FLAT
8| 103047| 1| CLUTCH SPRING
9| 103043| 1| BOTTOM GEAR, WIDE
10| 103044| 1| TORQUE PLATE, WIDE
11| 103994| 1| KEY, SHEAR PIN, STEEL
12| 100821| 1| WASHER CLUTCH
13| 104205| 1| SOLENOID ALIGNMENT LOCK, EU
14| 102536-1| 1| SCREW, 10-24, CUSTOM
| 104209-1| | SOLENOID, 24V, PULL TYPE, FAIL SECURE
15| 104209-2| 1| SOLENOID, 24V, PUSH TYPE, FAIL SAFE
| 104209-3| | SOLENOID, 12V, PULL TYPE, FAIL SECURE
| 104209-4| | SOLENOID, 12V, PUSH TYPE, FAIL SAFE
16| 100766| 1| SPRING, RETURN
17| 101509| 1| SPRING, RETURN, HELPER
18| 104212-1| 1| RACK ASSEMBLY, EU, RHR
104212-2| RACK ASSEMBLY, EU, LHR
| 104206-2| | COVER PLATE, MACHINED, EU, LHR
| 104206-1| | COVER PLATE, MACHINED, EU, RHR
19| 106459-2| 1| COVER PLATE, MACHINED, LS, EU, LHR
| 106459-1| | COVER PLATE, MACHINED, LS, EU, RHR
20| PP-5378-106| 2| SCREW, MACH, 8-32 x 3/8 PPH
21| 102291-108| 1| SCREW, MACH, 6-32 x 1/2 SEMS, PPH
PP-5367-110| SCREW, MACH, 6-32 x 5/8 PPH        (LS)
22| 104202| 1| TOP GEAR, MACHINED, EU
23| 104213-2| 1| LOCK SLIDE ASSY, EU, LHR
104213-1| LOCK SLIDE ASSY, EU, RHR
| 105673-1| | LEVER TRIM HARDWARE KIT, RIM, SVR
24KIT| 105673-2| 1| LEVER TRIM HARDWARE KIT, MORTISE
| 105673-3| | LEVER TRIM HARDWARE KIT, V
24A| 100754| 1| PLATE, CYLINDER POSITION
24B| 100783| 1| NUT, HEXAGON, CYLINDER
24C| 101478| | SHAFT EXTENSION ASSEMBLY
24D| 106694| 1| TAILPIECE ASSEMBLY, D TRIM, CVR UNIVERSAL
24E| 103218| | SHAFT, INPUT (MORTISE)
| 100572-9| 1| CYLINDER COLLAR, SHORT
100752-9| CYLINDER COLLAR, TALL
26| 105964| 1| WASHER, WAVE
27| 103800-626| 1| CYLINDER HOUSING, SFIC, MORTISE, 7 PIN, CHROME
102281-7-X| CYLINDER, MORTISE, 5 PIN, CHROME
28| 104207| 1| BRACKET, SOLENOID PLUNGER
29| PP-5378-104| 1| SCREW, MACH, 8-32×1/4″ PPH
PP-5378-106| SCREW, MACH, 8-32×3/8″ PPH (LS)
30| 104208| 1| BRACKET, SOLENOID
31| PP-5067-8| 1| LOCKWASHER, #8

ELECTRIC UNLOCK:
A DC power source is connected across the brown wires to power the internal solenoid. The solenoid connection is not polarized. The applied voltage will unlock for Fail-Secure and lock for Fail-Safe. Units are color coded as follows:
24 VDC Fail-Secure (Black spiral cover) p/n 104209-1
24 VDC Fail-Safe (Red spiral cover) p/n 104209-2
12 VDC Fail-Secure (Blue spiral cover) p/n 104209-3
12 VDC Fail-Safe (Yellow spiral cover) p/n 104209-4

LHR ASSEMBLIES SHOWN

RHR assemblies have switch assemblies & levers on opposite side
NOTE: Assemblies CANNOT be rehanded

STEP 1: PREP TRIM DEVICE

Install tailpiece for RIM, SVR or input shaft for MORTISE and cylinder

NOTE: Mortise cylinder NOT supplied with trim, but can be ordered separately

LHR ASSEMBLIES SHOW

STEP 2a: PREP DOOR (Rim & SVR

NOTES:

  1. For a retrofit application, remove lock and device before installing new trim.
  2. LHR installation shown (Reverse all steps for RHR).

PREP DOOR
PREP DOOR
PREP DOOR

STEP 2b: PREP DOOR (Mortise)

Use plastic template to mark the locations shown below

 DETEX 104200 Lever Trim Instruction Manual  PREP DOOR

STEP 3a: INSTALL TRIM DEVICE (Rim & SVR)

Install TRIM for Rim & SVR Device

INSTALL TRIM DEVICE

STEP 3b: INSTALL TRIM DEVICE (Mortise)

Install TRIM for Mortise Device

NOTE:

  1.  Mortise lock NOT supplied with TRIM device.

INSTALL TRIM DEVICE

STEP 4: ROUTING WIRES THROUGH DEVICE

Wires can be routed through device or door

NOTE:

  1. Detex recommends the power supply to located within 15 feet of the device.

  2. Detex recommends using minimum 20 GA
    wire for power.

  3.  Current draw: 24VDC = 150 mA
    12VDC = 250 mA
    ROUTING WIREROUTING WIRES