Overview
W116 series are panel temperature data loggers which support Bluetooth connection (ESC protocol), monitor and record the temperature data of food, medicine, chemical supplies, and other objects during storage and transportation.
Dimension & Weight
- Whole:99.4 70.2 11.4 mm (WHT)
- Front Panel :99.4 70.2 2 mm (WHT)
- Back Panel :82.5 48.5 9.4 mm (WHT)
- Net weight: 65 gsm
Buttons and Operation Method
There are 3 buttons on the right of the front panel. Mainly exist two
actions:
- Short Press: Press the button and release at once.
- Long Press: hold down the button for 4 seconds.
Power
Built-in Li-ion Battery, the type C interface is used for charging and data
transmission.
Power on/off
[Power on] Plug it into a type-C charger;
[Power off] Unplug the type-c charger, make sure the buttons are not locked,
and then press and hold all the buttons for 4s to shut down.
Enable Recording
Long press the button to activate the recording, and the screen will show if
successful.
Disable Recording
Long press the button to stop the recording, the screen will show if
successful.
Select A Trip From the Trips List
Short press the button, and the screen will show which means all trips; Now
you can press the key (Next) or the key (Previous) to select one trip;
Print One Trip’s Data
Long press the button to print one trip’s data, and the screen will show ,
which means it will print soon.
Tip: it will print the latest trip if you did not select it.
Output Data And Generate Reports
Connect this device to a computer by a type C cable, and you will find a
U-Disk that stores all data and reports, more options are available with the
help of the accompanying software.
LCD Diagram
- Temperature display interface
- Date display interface
- Time display interface
- Upper limit display interface
- Lower limit display interface
- Record points display interface
- USB connection status icon
- Battery level
- Keys lock icon
- No alarm icon
- Over limit icon
- Record status icon
- Non-recording status icon
- Temperature unit
- Bluetooth identifier
- Lowest temperature record display interface
- Highest temperature record display interface
LCD Menu
Battery Level Instruction
Note
- When the remaining battery capacity is less than 20%, it is recommended to replace the battery to prevent inconvenience;
- When the remaining battery capacity is less than 10%, please replace the battery as soon as possible to prevent the battery from running out.
Packing List
- 1 piece of panel data logger with Built-in Li-ion Battery
- 1 piece of the user manual
- 1 piece of eg: MHT-P16 Bluetooth Printer (Optional)
The data logger has a built-in expandable list of printer names and automatically connects to the printers in the list via the Bluetooth “ESC” protocol. With the help of the developer, additional bluetooth printers can be supported by upgrading the list of printer names.
Factory Default Parameters
Temperature unit: °C | Export file type: PDF |
---|---|
Time zone: UTC +8:00 | Report language: English |
Start mode:
start by pressing key
| Start delay: 0 min
Stop mode:
stop by pressing key
| Temperature offset value:
±0.0°C
Temperature upper limit: W116B:70.0°C; W116C:100°C| Temperature lower limit: W116B: -40.0°C; W116C:-200°C
Normal record interval: 1min
|
Overlimit record interval: 30s
Circular log: enabled
|
Multiple start: enabled
Long press keys to delete data: enabled
|
Reset record after finishing configuration: disabled
LCD always on: timing off
|
Alarm setting: no alarm
Trip No.: XC000000
|
Trip description: NULL
- Long press:hold the key for no less than 4s.