HASWILL ELECTRONICS STC-9100 Defrosting Temperature Controller User Guide

June 11, 2024
HASWILL ELECTRONICS

STC-9100 Thermostat
Quick Start Guide
(Version 22.11.03GEN)
Video on YouTube

STC-9100 Defrosting Temperature Controller

STC-9100 defrosting temperature controller controls three loads: the refrigeration device, the defrosting unit, and the External Alarm.

Wiring Diagram

HASWILL ELECTRONICS STC 9100 Defrosting Temperature Controller - Wiring
Diagram

| Live
---|---
| Neutral/Nuil
| Earth
Co| Power Supply Input
| Compressor
| Defrosting
| Alarm
7| Room Sensor
9| Defrosting Sensor
8| Co-point of Sensos

Set the temperature

Please learn that the room temperature was supposed to keep at the range from “F1” to “F1 + F2” (“SET” to “SET + HY”).
You can set them in both the user interface and the Admin Interface. Below is the 2nd method.
Step 1: Enter the Admin Interface: hold the [SET] key and the [ ] key at the same time for 10s; you will see the code “F1” (“SET”).
Step 2: Press the [SET] key to check current value, and press the key or the key to change the F1 value;
Step 3: Press the [SET] key to save the new data, and back to the menu list, you will see the code “F1” (“SET”) again.
Step 4: Switch to the “F2” (“HY”) code by press the key. Repeat the above 2-4 steps to update all the code you want to.
At last: Just leave the unit alone; it will auto quit from setting mode back to normal status in 10s.

  1.  F1 (SET): SP (Temperature Set-Point)
  2. F2 (HY): Temperature Hysteresis / Return Difference
  3. F3 (US): Upper limit for SP
  4. F4 (LS): Lower limit for SP
  5. F5 (AC): Delay Time for the Compressor and Delay time for defrosting if it was Hot Gas mode F10 = 1 (TDF = HTG)

If you found the “F1” (SET) value cannot be modified to the value you need, please adjust the F3 and F4 (the US and the LS), which are the limitation for F1 (SET).

Configure the Defrosting

This unit controls the defrosting by Time and Temperature.
Temperature Condition: the evaporation sensor temperature is lower than the preset “defrosting Stop temperature” F8 (dte), which is a significant value to prevent over defrost.
Time Condition 1: the real-time passes the preset interval time F6 (idf), a regular parameter for almost all defrosting thermostats.
Time Condition 2: If the “defrosting method” you take is the hot gas from the compressor reverse rotary when F10 = 1 (tdf = HTG), it will count the compressor’s last stops moment plus F5 (ac), which is a protective value to avoid the compressor frequently startup and stops.
The operates method is just like page 1 shows;
6) F6 (IDF): Defrosting Cycle / Interval Time
7) F7 (ADF): Defrosting Lasting/Running Time
8) F8 (DTE): Defrosting Stop Temperature
9) F9 (FDT): Defrosting Water Dripping Time
10) F10 (TDF): Defrosting Mode:

  • 0 (EL): Electric-Heating.
  • 1 (HTG): Hot Gas from the compressor.
  1. F11 (DCT): Count mode of defrost cycle:
  • 0 (RT): Cumulative time from the controller power on.
  • 1 (COH): Cumulative time of the compressor working.
  1. F12 (DFD): Display mode when defrosting:
    A. 0 (RT): Shows the room sensor temperature display.
    B. 1 (IT): Shows the evaporator sensor temp. (continue showing 10 minutes once defrosting over)

Set the External Alarm?

Unlike other defrost thermostats, which only reference the room sensor, this unit STC-9100 also monitors the evaporator sensor temperature.
Check the Alarm output options in F13 (DMO):

Code Description
N-C/0 The alarm output’s function was banned.
A-C/1 The alarm follows the buzzer status
A-A/2 It cannot be canceled before fixed all errors.

And then check below items

Sensor Position EN Code F code Meaning
Evaporator ELL F14 Lower Limit
EOD F15 Time delay
ELU F16 Upper Limit
Room ALU F17 Upper Limit
ALL F18 Lower Limit
ALD F19 Time delay

This is not a step-by-step user manual;
It just shows the key points.
The new user should read the Full-Content Version User Manual

https://www.thermo-hygro.com/

Haswill Electronics
www.thermo-hygro.com
Copyright Haswill-Haswell All Rights Reserved

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

HASWILL ELECTRONICS User Manuals

Related Manuals