SAFETY INSTRUCTIONS
Attention! This user manual is an essential part of this product.
The user manual should be read carefully before you use the product for the
first time. If the product is given to someone for temporary use, be sure to
enclose the user manual to it.
- Do not misuse the product;
- Do not remove warning signs and protect them from abrasion, because they contain information about the safe operation of the product.
Omniliner 3D | Omniliner G3D |
---|
Laser radiation! Do not stare into beam
Class 2 laser| Class 2 laser
<1 mW 635 nm| <1 mW 520 nm
EN60825-1: 2007-03| EN60825-1: 2007-03
- Do not look into the laser beam or its reflection, with an unprotected eye or through an optical instrument. Do not point the laser beam at people or animals without the need. You can dazzle them.
- To protect your eyes close them or look aside.
- Always install the product in such a way, so that the laser line is below or above eye level.
- Do not let unauthorized people enter the zone of product operation.
- Store the product beyond the reach of children and unauthorized people.
- It is prohibited to disassemble or repair the product yourself. Entrust product repair to qualified personnel and use original spare parts only.
- Do not use the product in an explosive environment, close to flammable materials.
- Laser intensive glasses are used for better recognition of the laser beam, do not use them for other purposes. Laser glasses do not protect from laser radiation as well as ultraviolet radiation and reduce color perception.
- Avoid heating the batteries to avoid the risk of explosion and electrolyte leakage. In case of liquid contact with skin, wash it immediately with soap and water. In case of contact with the eyes, flush with clean water during 10 minutes and consult the doctor.
PRODUCT DESCRIPTION
CCross line lasers Omniliner 3D/G3D CONDTROL are intended to project vertical
and horizontal planes. They project one 360° horizontal and two 360° vertical
planes and provide compensation of the slope up to ±4°. The laser levels have
2 operating modes:
– Automatic leveling to compensate irregularities within the self-leveling
range of ± 4°;
– Locked compensator, to project inclined planes and lines.
Pulse mode allows using a laser receiver to increase the working range of the
laser level or to work when the laser is hard to define in bright lighting
conditions.
The laser levels are suitable for use in both indoor and outdoor building
areas.
- 1 – Laser lines exit window
- 2 – Control panel
- 3 – Battery cover
- 4 – Tripod thread 1/4’’
- 5 – Tripod thread 5/8’’
- 6 – Switch bar
- 7 – Hole for mounting on a screw/nail
Control panel
-
Switch on/off:
– The laser level
– laser lines -
Switch on/off pulse mode
-
Power indicator
-
Indication of locked pendulum
-
Indication of pulse mode
DELIVERY PACKAGE
Omniliner 3D/G3D
Laser level, battery 2 pcs., charger, bag, user manual.
Omniliner 3D Kit/G3D Kit
Laser level, battery 2 pcs., charger, magnetic target, wall mount, clamp, user
manual, plastic case.
TECHNICAL SPECIFICATIONS
| Omniliner 3D| Omniliner G3D
---|---|---
Working range/ with receiver*| 40 m/80 m| SO m/80 m
Self-levelling accuracy| ±0,2 mm/m
Self-levelling range| ± 4°
Self-leveling duration, typically| <3″
Continuous working time| >10 hours| >5 hours
Working temperature| -10°C … +50°C
Storage temperature| -20°C … +70°C
Relative humidity| <90%
Dust and water
protection rate| IP6S
---|---
Thread for mounting on a tripod| 1/4″, 5/8″
Laser type| Class II 635 nm
< 1 nnW| Class II 520 nm
< 1 mW
Battery| 3.7V 5200 mAh Li-ion
Dimensions| 140x138x110 mm
Weight
– without battery
– with battery| 660 g
774 g
- Working range may differ from the stated above and depends on lighting conditions.
BEFORE START OPERATION
Power supply
The cross-line laser is powered via a 3.7V 5200 mAh Li-ion battery included in
the delivery package.
Install/charge the Li-ion battery
Install the battery in the battery compartment, observing the polarity.
Use the battery included in the delivery package only.
If the power indicator on the control panel starts flashing red, the battery
must be charged.
The charging procedure is as follows:
-
Remove the battery from the laser level.
-
Connect the battery to the power source by the charger included in the delivery package.
The power indicator on the charger will be red while charging. -
The battery charging time is about 5 hours.
-
Once the power indicator on the charger turns green, disconnect the charger and install the battery in the battery compartment.
OPERATION
Place the laser level on a firm and stable surface or a tripod and moves the switch bar to select the necessary operating mode:
-
Automatic leveling
Move the switch bar to the unlocked position . H-line will automatically switch on.
Short press button to switch on required laser lines.
If the laser level is out of the range of automatic compensation laser lines will flash 1 time per second.
Short press the button to switch on/off the pulse mode.
To switch off the laser level move the switch bar to the position . -
Projection of inclined planes
Move the switch bar to a locked position .
Press and hold during 3 seconds to switch on the laser.
Short press to switch on required laser lines.
Switched on laser lines will flash 1 time per every 5 seconds.
Long press for 3 seconds will switch off the laser level.
Long press during 3 seconds to switch on/off the pulse mode.
Bluetooth
Bluetooth is always on by default. Switch on the laser level. Activate
Bluetooth on your portable device and start the app “XLiner Remote”. Perform
connection via Bluetooth. The app allows switching on and off the laser lines,
and receiver mode, as well as adjusting the brightness of the laser for
optimal visibility and energy saving and controlling the battery charge level
without touching the laser level.
Attention! To increase the operating time and avoid the risk of
unintentional blindness switch the laser on only when you are ready to make
measurements. If operated near objects or air streams with different from the
environment temperature the laser line may tremble due to the heterogeneity of
the atmosphere. The longer is the distance, the more trembling can be observed
The width of the laser line increases with the increase of the operating
distance. The layout should be made along the axis of the laser line. For
maximum accuracy, use the middle portion of the laser line. It should be noted
that the shape of the laser line on the object’s surface (e.g., walls,
ceilings, etc.) depends on the curvature and tilt of the surface relative to
the laser plane.
ACCURACY CHECK
Check of the horizontal line
Use 2 parallel vertical walls which are located opposite each other at a
distance of 5 m.
-
Set the instrument close to wall A (see Fig. A). Switch on the vertical and horizontal laser emitters, and unlock the compensator. Turn the instrument in such a way so that the laser lines intersecting each other are projected near wall A opposite the instrument. Mark the point where laser lines intersect each other as A1.
-
Turn the instrument by 180°, and mark the point where laser lines intersect each other on the opposite wall as В2. (see Fig. В).
-
Move the instrument to the opposite wall B and set it in such a way that the point where laser lines intersect each other would be on the same level with point B2.
-
Turn the instrument by 180°, and direct the instrument to the wall А in such a way so that the vertical line would coincide with point А1. Mark the point of intersecting laser line on the wall А as A3. (see. Fig. D).
-
Measure distance d between points А1 and А3 (see. Fig. D). If this distance exceeds 2 mm, please contact a service center.
Check of vertical line
Use a plumb bob as a reference for a vertical line. Place the
the instrument at a distance of 1,5m from the plumb bob.
- Unlock the compensator, switch on the vertical laser line and align it with the low point of a plumb bob.
- If the deviation between the laser line and the plumb bob line exceeds ±0.2 mm per 1 m of the plumb bob length (for a 2.5 m plumb bob deviation shouldn’t exceed 0.5 mm) please contact the service center.
- Turn the instrument by 180° and align the vertical laser line with the low point of plumb bob once again.
CARE AND MAINTENANCE
Attention! The product is an accurate optical mechanic device and
requires careful handling. Check the accuracy before using.
Maintenance of the following recommendations will extend the life of the
device:
-
Store the product, spare parts, and its accessories beyond the reach of children and unauthorized people.
-
The product should be transported only when the compensator is locked.
-
Keep the product clean and protected from any bumps, dust, and dampness; do not allow getting moisture, dust, or other dirt inside of the product.
-
In case if any moisture goes into the product, remove the batteries and take it to the service center.
-
Do not keep or use the device for a long time in high humidity conditions.
-
Carry out accuracy checks regularly (see paragraph «Accuracy check»).
-
To clean the product using a soft wet cloth. Do not use harsh chemicals, cleaning solvents or detergents.
-
Сlean laser aperture periodically with a soft lint-free cloth with isopropyl alcohol.
Mishandling of the following rules can cause electrolyte leakage from the batteries or other damages: -
Remove the battery from the product if you do not use it for a long time.
-
Do not leave discharged battery in the laser level.
UTILIZATION
Expired tools, accessories, and packages should be passed for waste recycle.
Please send the product to the following address for proper recycling:
**** CONDTROL GmbH
Im Wiegenfeld 4
85570 Markt Schwaben
Germany
Do not throw the product in municipal waste! According to European directive 2002/96/ЕC expired measuring tools and their components must be collected separately and submitted to environmentally friendly recycling of wastes.
WARRANTY
All CONDTROL GmbH products go through post-production control and are governed by the following warranty terms. The buyer’s right to claim about defects and general provisions of the current legislation does not expire.
- CONDTROL GmbH agrees to eliminate all defects in the product discovered while the warranty period, which represents the defect in material or workmanship in full volume and at its own expense.
- The warranty period is 24 months and starts from the date of purchase by the end consumer (see the original supporting document).
- The Warranty doesn’t cover defects resulting from wear and tear or improper use, malfunction of the product caused by failure to observe the instructions of this user manual, untimely maintenance and service and insufficient care, and the use of non-original accessories and spare parts. Modifications in the design of the product relieve the seller from responsibility for warranty works. The warranty does not cover cosmetic damage, that doesn’t hinder the normal operation of the product.
- CONDTROL GmbH reserves the right to decide on the replacement or repair of the device.
- Other claims not mentioned above, are not covered by the warranty.
- After holding warranty works by CONDTROL GmbH warranty period is not renewed or extended.
- CONDTROL GmbH is not liable for loss of profit or inconvenience associated with a defect of the device, or the rental cost of alternative equipment for the period of repair. This warranty applies to German law except the provision of the United Nations Convention on contracts for the international sale of goods (CISG). In warranty case please return the product to the retail seller or send it with a description of defect to the following address:
CONDTROL GmbH
Im Wiegenfeld 4
85570 Markt Schwaben
Germany
Documents / Resources
|
CONDTROL Omniliner 3D/G3D Cross Line Level
Laser
[pdf] User Manual
Omniliner 3D G3D, Cross Line Level Laser, Omniliner 3D G3D Cross Line Level
Laser, Omniliner 3D, Omniliner G3D
---|---
|
CONDTROL Omniliner 3D/G3D Cross Line Level
Laser
[pdf] User Manual
Omniliner 3D G3D, Cross Line Level Laser, Omniliner 3D G3D Cross Line Level
Laser, Omniliner 3D, Omniliner G3D, Cross Line Laser
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>