Attention! This user manual is an essential part of this product. The user manual should be read carefully before you use the product for the first time. If the product is given to someone for temporary use, be sure to enclose a user manual to it.
- Do not misuse the product
- Do not remove warning signs and protect them from abrasion, because they contain information about safe operation of the product.
- Do not look into the laser beam or its reflection, with unprotected eye or through an optical instrument. Do not point the laser beam at people or animals without the need. You can dazzle them.
- To protect your eyes close them or look aside.
- Always install the product in such a way, so that laser line is below or above eye level.
- Do not let unauthorized people enter the zone of product operation.
- Store the product beyond reach of children and unauthorized people.
- It is prohibited to disassemble or repair the product yourself. Entrust product repair to qualified personnel and use original spare parts only.
- Do not use the product in explosive environment, or close to flammable materials. Laser intensive glasses are used for better recognition of the laser beam, do not use them for other purposes. Laser glasses do not protect from laser radiation as well as ultraviolet radiation and reduce color perception.
- Avoid heating the batteries to avoid the risk of explosion and electrolyte leakage. In case of liquid contact with skin, wash it immediately with soap and water. In case of contact with eyes, flush with clean water for 10 minutes and consult the doctor.
PRODUCT DESCRIPTION
Cross-line laser Xliner Duo/Combo 360 CONDTROL is intended to build and check
vertical and horizontal planes and lines, as well as up and down laser dots*
(zenith and nadir). The laser level is suitable for use in both indoor and
outdoor building areas.
The laser level has 2 operating modes
- automatic leveling to project horizontal and vertical planes and lines. Leveling function allows to automatically compensate irregularities within self-leveling range of ±4°;
- locked compensator, to build inclined planes and lines; Pulse mode allows using a laser receiver to increase the working range of the laser level or to work when the laser is hard to be defined in bright lighting conditions.
- Cleaner Combo 360 only.
- Laser lines exit windows
- Control panel
- Battery cover
- 1/4’’mounting thread
- 5/8’’ mounting thread
- Compensator lock
Control panel
- Switch on/off:
- the laser level
- laser planes
- Switch on/off pulse mode 3 Power indicator
- Pulse mode indicator
TECHNICAL SPECIFICATIONS
Working range/with receiver | 40 m/80 m |
---|---|
Self-leveling accuracy | ±0,2 mm/m |
Self-leveling range | ± 4° |
Continuous working time | >8 hours |
Operating temperature | -10°C … +50°C |
Storage temperature | -20°C … +70°C |
Relative humidity | 90% |
Protection rating | IP54 |
Tripod mounting thread | 1/4’’ and 5/8’’ |
Laser type | Class II 635 nm < 1 mW |
Power supply | 4 х 1.5V LR6 alkaline (AA) |
Dimensions | 119x62x115 mm |
Weight | 0,445 kg |
SET
- Cross line laser – 1 pcs.
- Carry bag – 1 pcs.
- Batteries (АА) – 4 pcs.
- User manual – 1 pc.
OPERATION
Before starting the operation removes the battery cover, insert the batteries,
observing the correct polarity. Put the battery cover back. Use AA alkaline
batteries only, all batteries should be of the same type and brand with the
same charge level. Replace batteries if the battery charge level indicator
starts flashing red while operating. Place the laser level on a firm and
stable surface or a tripod. Move the compensator lock to choose a necessary
operating mode:
Automatic leveling:
Move the lever lock to the ON position .
The compensator is unlocked. The power indicator becomes red. If the laser
level is out of the range of automatic compensation laser lines flash.
Short press the button to switch on the necessary laser planes.
Short press button to switch on/off pulse mode that allows working with a
laser receiver. In this mode, the pulse mode indicator will turn red. To
switch the laser level off move the compensator lock to the locked position.
Locked compensator, to build inclined planes and lines:
Move the compensator lock to the OFF position. The compensator is locked. The
power indicator becomes red. Press and hold the button for 3 seconds to switch
the laser level on. Short press the button to switch on the necessary laser
planes. Activated laser lines flash every 5 seconds in this mode. Short press
button to switch on/off pulse mode that allows working with laser receiver. In
this mode pulse mode indicator will turn red. To switch the laser level off
short press button several times until all laser planes are off.
Attention! To increase operating time and avoid the risk of unintentional
blindness switch the laser on only when you are ready to work. If operated
near objects or air streams with the temperature different from the
environment the laser line may tremble due to heterogeneity of the atmosphere.
The longer the distance, the more trembling of the laser line can be observed.
The width of the laser line increases as soon as operating distance increases
as well. The layout should be made along the axis of the laser line. For
maximum accuracy, use the middle portion of the laser line. It should be noted
that the shape of the laser line on the object’s surface (e.g., walls,
ceilings, etc.) depends on the curvature and tilt of the surface relative to
the laser plane.
ACCURACY CHECK
Check of horizontal line
Check of horizontal line is carried out by using 2 walls A and B located
opposite each other at 5m distance.
- Install the laser level as close as possible to wall A (see Fig.A). Unlock compensator and switch on vertical and horizontal lines. Expand the device emitters in the direction of wall A so that the crossing of the laser lines on the wall is located in front of the laser level. Mark the crossing point of laser lines as A1. Mark point B on the wall B.
- Turn the instrument by 90°. Check misalignment of horizontal line and point B1 (see Fig. B). If deviation between the laser line and the B1 mark exceeds 1 mm, please contact service center.
- Repeat step 2 for 2 more times, turning the laser level in one direction.
- Install the laser level closer to wall B, mark the crossing point of laser lines as B2 (marks В1 and В2 should be located on the same vertical line) (see Fig.C).
- Turn the instrument by 180° and mark the crossing point of the laser lines on the wall as A2 (marks A1, A2 should be located on the same vertical line) (see Fig.D).
- Check the distance dA, dB between marked points A1, A2 and B1, B2 accordingly (see Fig. D). If deviation between dA, dB values exceeds 2 mm, please contact service center.
Check the vertical line
Use a plumb bob as a reference for a vertical line. Place the laser level at a
1,5m distance from the plumb bob (see Fig. E).
- Move the compensator lock to the ON position, then switch on vertical plane and align vertical laser line with the low point of plumb bob.
- If deviation between the laser line and the plumb line exceeds 0.2 mm per 1m of the plumb bob length (for a 2.5m plumb bob deviation shouldn’t exceed 0.5 mm) please contact service center.
CARE AND MAINTENANCE
Maintenance of the following recommendations will extend the life of the device:
-
Transport and carry the product only with locked compensator.
-
Keep the product clean and protected from any bumps, dust and dampness; do not allow getting moisture, dust or other dirt inside of the product.
-
In case if any moisture goes into the product, remove the batteries and take it to the service center.
-
Do not keep or use the device for a long time at high humidity conditions.
-
Keep the instrument clean and wipe it with a clean and soft cloth.
-
Mishandling of the following rules can cause electrolite leakage from the batteries or other damages:
-
Remove the batteries from the product if you do not use it for a long time.
-
Do not use different battery types with different charge levels.
-
Do not leave discharged batteries in the product.
UTILIZATION
Expired tools, accessories and package should be passed for waste recycle.
Please send the product to the following address for proper recycle:
Condtrol GmbH Wasserburger Strasse 9 84427 Sankt Wolfgang
Germany
Do not throw the product in municipal waste!
According to European directive 2002/96/ЕC expired measuring tools and their
components must be collected separately and submitted to environmentally
friendly recycle of wastes.
WARRANTY
All Condtrol GmbH products go through post-production control and are governed
by the following warranty terms. The buyer’s right to claim about defects and
general provisions of the current legislation do not expire.
- Condtrol GmbH agrees to eliminate all defects in the product, discovered while warranty period, that represent the defect in material or workmanship in full volume and at its own expense.
- The warranty period is 24 months and starts from the date of purchase by end consumer (see the original supporting document).
- The Warranty doesn’t cover defects resulting from wear and tear or improper use, malfunction of the product caused by failure to observe the instructions of this user manual, untimely maintenance and service and insufficient care, the use of non-original accessories and spare parts. Modifications in design of the product relieve the seller from responsibility for warranty works. The warranty does not cover cosmetic damage, that doesn’t hinder normal operation of the product.
- Condtrol GmbH reserves the right to decide on replacement or repair of the device.
- Other claims not mentioned above, are not covered by the warranty.
- After holding warranty works by Condtrol GmbH warranty period is not renewed or extended.
- Condtrol GmbH is not liable for loss of profit or inconvenience associated with a defect of the device, rental cost of alternative equipment for the period of repair.
This warranty applies to German law except provision of the United Nations Convention on contracts for the international sale of goods (CISG).
In warranty case please return the product to retail seller or send it with description of defect to the following address:
- Control GmbH