CONDTROL Fliesen 3D Laser Cross Line Laser User Manual

June 3, 2024
CONDTROL

CONDTROL Fliesen 3D Laser Cross Line Laser

Congratulations on your purchase of laser level CONDTROL Fliesen 3D Laser.
Safety regulations can be found in this user manual and should be carefully read before you use the device for the first time.

SAFETY INSTRUCTIONS

The user manual should be read carefully before you use the device for the first time. Unintended use of the device can be dangerous for human’s health and cause serious injury. Keep this user manual. If the device is given to somebody for temporary use, be sure to enclose user manual to it.

  • Do not misuse the device.
  • Do not remove warning signs and protect them from abrasion, because they contain information about safe operation of the device.
  • Laser radiation! Do not stare into beam Class 2 laser <1 mW 520 nm
  • EN60825-1: 2007-03
  • Do not look into the laser beam or its reflection, with unprotected eye or through an optical instrument. Do not point the laser beam at people or animals without the need. You can dazzle them.
  • To protect your eyes close them or look aside.
  • Always install the product in such a way, so that the laser line is below or above the eye level.
  • Do not let unauthorized people enter the zone of the product operation.
  • Store the product beyond reach of children and unauthorized people.
  • It is prohibited to disassemble or repair the product yourself. Entrust product repair to qualified personnel and use original spare parts only.
  • Do not use the product in explosive environment, close to flammable materials.
  • Avoid heating the batteries to avoid the risk of explosion and electrolyte leakage. In case of liquid contact with skin, wash it immediately with soap and water. In case of contact with eyes, flush with clean water during 10 minutes and consult healthcare practitioner.

PRODUCT DESCRIPTION

Laser-level Fliesen 3D Laser CONDTROL is designed for projecting and controlling of vertical and horizontal planes and lines.
The laser level has 2 operating modes:

  • Locked compensator, to project inclined planes and lines;
  • Automatic leveling, which allows to automatically
  • compensate irregularities within self-leveling range of ±5°. Pulse mode allows to increase working range of the laser level by using the laser receiver or to work when laser is hard to define in bright lighting conditions.
  • This laser level is suitable for use at both indoor and outdoor building areasCONDTROL-Fliesen-3D-Laser-Cross-Line-Laser-FIG-1
  1. Laser beam exit windows
  2. Control panel
  3. Battery door
  4. Tripod thread 1/4’’
  5. Switch bar
  6. Magnets for fixing on vertical structures
  7. Hole for fixing by the cable tie
  8. Hole for fixing on a screw/nail

Control panel

  1. Switch on/off the laser lines
  2. Switch on/off the pulse mode
  3. Power indicator
  4. Indicator of inclined planes mode
  5. Indicator of pulse mode

TECHNICAL SPECIFICATIONS

Working range/ with receiver*|

20 m/40 m

---|---
Self-levelling accuracy| ±0.3 mm/m
Self-levelling range| ± 5°
Working temperature| -10°C … +50°C
Storage temperature| -20°C … +70°C
Relative humidity| 90%
Dust and water protection rate|

IP54

Thread for mounting on a tripod|

1/4’’

Laser type| Class II 520nm < 1 mW

Battery

| 3.7V 3000 mAh Li-ion rechargeable
Dimensions| 112x64x116 mm
Weight

– with battery

– without battery

|

0.42 kg

0.35 kg

DELIVERY PACKAGE

  • Laser level – 1 pc.
  • Cable tie – 1 pc.
  • Battery (3.7V 3000 mAh Li-ion) – 1 pc.
  • Adapter for alkaline batteries – 1 pc.
  • Lifting platform – 1 pc.
  • Charging cable – 1 pc.
  • Laser-intensive glasses – 1 pc.
  • Magnetic target board – 1 pc.
  • User manual – 1 pc.
  • Plastic case – 1 pc.

BEFORE START OPERATION

  • Power supply
  • The laser level is powered by a 3.7V 3000 mAh Li-ion rechargeable battery included in the delivery package.
  • Install/replace batteries/charge the Li-ion battery
  • Install the battery in the battery compartment, observing the polarity.
  • Use only the battery included in the delivery package.
  • If the power indicator on the control panel becomes red, charge the battery.
    The battery should be charged in the following way:
  1. Remove the battery from the device.
  2. Connect the charger to the power source with a charging cable, included in the delivery package.

The battery charging time depends on the current of the used adapter:

| Current| Charging time

---|---|---
1| 500 mA| 6 hours
2| 1000 mA| 3 hours
3| 2A| 1.5 hours

Note: It is forbidden to use adapters with an output voltage of more than 5V! It may lead to damage of the battery.

  1. As soon as the charging time runs out, disconnect the charger and put the battery in the battery compartment. Adapter for alkaline batteries is included in the delivery package. Insert alkaline batteries (type AA 1.5V) in adapter and continue to use the laser level, while Li-ion battery is being charged.

OPERATION
Install the device on a firm and stable surface or tripod. Move the switch bar to select the required operation mode:

Automatic leveling

  • Move the switch bar to position ON.
  • The laser level will switch on. The LED indicator is green.
  • Upper H-line is on.
  • Short press to switch on required laser lines.
  • Short press to switch on/off the pulse mode. When
  • pulse mode is on, the LED indicator is green.
  • Move the switch bar to position OFF to switch off the laser level.
  • When the battery is low, the LED indicator is flashing red.

Inclined lines

  • The switch bar is in position OFF.
  • Press and hold for 3 seconds to switch on the laser.
  • Upper H-line is on. The laser line is flashing every 5 seconds. The LED indicator is red.
  • Long press for  3 seconds to switch on the required laser lines.
  • After all combinations of lines are switched on, the next long
  • press will switch off the laser level.
  • Press and hold for 3 seconds to switch on/off the
  • pulse mode. When pulse mode is on, the LED indicator is green.

Note: To increase the operating time and avoid the risk of an unintentional blinding switch on the laser only before starting the operation. If operated near objects or airflows different from the environment temperature the laser line may tremble due to the heterogeneity of the atmosphere. The longer the distance, the more trembling can be observed. The width of the laser line increases with the increase of the operating distance. The marking should be made along the axis of the laser line. For maximum accuracy, use the middle portion of the laser line. It should be noted that the shape of the laser line on the object’s surface (e.g. walls, ceilings) depends on the curvature and slope of the surface relative to the laser plane.

ACCURACY CHECK

Horizontal line

Check of a horizontal line is carried out by using 2 walls located opposite each other at a 5m distance.

  1. Put the laser level to one of the walls as close as possible (Figure A). Move the switch bar to position ON and switch on both vertical and horizontal planes. Rotate the laser levels that laser emitters are located opposite to the near wall and laser lines cross each other. Mark the location of laser lines crossing as А1. Mark the location of laser lines crossing on another wall as B1.
  2. 2. Rotate the laser level by 90°, and measure the deviation of a laser line from point В1 (Figure B). If the deviation exceeds 1.5 mm please contact the service center.
  3. Repeat actions described in point 2 twice, rotating the laser level in one direction.
  4. Install the laser level closer to the opposite wall. Mark location of laser lines crossing as В2 (points В1, В2 must be located at the same vertical) (Figure C).
  5. Rotate the laser level by 180°and mark location of laser lines crossing on the opposite wall as A2 (points A1, A2 must be located at the same vertical) (Figure D).
  6. Measure distances dA, dB between points А1, А2 and В1, В2 accordingly (Figure D). If difference between values dA, dB exceeds 3 mm – please contact the service center.

Attention: please do accuracy check for each horizontal plane separately.

Vertical line
Use a plumb bob as a reference of a vertical line. Put the laser level at 1.5m distance from the plumb bob. (Fig. E).

  1. Move the switch bar on position ON, and align vertical laser line with the low point of plumb bob.
  2. If deviation between the laser line and the plumb line exceeds 0,3 mm per 1m of plumb bob length (for a 2.5m plumb bob deviation shouldn’t exceed 0.7 mm) – please contact the service center.

CARE AND MAINTENANCE

Attention! This laser level is a precise optic-mechanical device and requires careful handling. Before starting work, as well as after mechanical influences (falling, bumps), check the accuracy of the device.
Observation of the following recommendations will extend the life of the device:

  • Store the device, spare parts, and accessories away from children and unauthorized people.
  • Transport the device with a locked compensator only.
  • Protect the device from bumps, falls, and excessive vibration; do not let moisture, construction dust, and foreign objects get inside the device.
  • In case moisture gets inside the device, first of all, remove the batteries and then contact the service center.
  • Do not store or use the device for a long time in high humidity conditions.
  • Check the accuracy of the device occasionally (check the paragraph «Accuracy check»).
  • Clean the device with a soft wet cloth. Do not use harsh chemicals, cleaning solvents or cleaning agents.
  • Wipe the laser aperture with a soft lint-free cloth and isopropyl alcohol.
  • Remove the Li-ion battery or alkaline batteries from the device before connecting the charger, otherwise the device may fail.

Failure to observe the following rules may lead to electrolyte leakage from the batteries and failure of the device:

  • Remove the batteries from the device, if it’s not used for a long time.
  • Do not leave discharged batteries in the device.
  • Avoid heating the batteries to avoid the risk of explosion and electrolyte leakage. In case of liquid contact with skin, wash it immediately with soap and water. In case of contact with eyes, flush with clean water during 10 minutes and consult the doctor.

UTILIZATION
Expired tools, accessories and package should be passed for waste recycle. Please send the product to the following address for proper recycle:
CONDTROL GmbH
Wasserburger Strasse 9 84427 Sankt Wolfgang
Germany
Do not throw the product in municipal waste! According to European directive 2002/96/ЕC expired measuring tools and their components must be collected separately and submitted to environmentally friendly recycle of wastes.

WARRANTY

All CONDTROL GmbH devices go through post-production control and are governed by the following warranty terms. The buyer’s right to claim about defects and general provisions of the current legislation do not expire.

  1. CONDTROL GmbH agrees to eliminate all defects in the device, discovered during the warranty period, that represent the defect in material or workmanship in full volume and at its own expense.
  2. The warranty period is 24 months and starts from the date of purchase by the end customer (see the original supporting document).
  3. The warranty doesn’t cover defects resulting from wear and tear or improper use, malfunction of the device caused by failure to observe the instructions of this user manual, untimely maintenance and service and insufficient care, the use of non-original accessories and spare parts. Modifications in design of the device relieve the seller from responsibility for warranty works. The warranty does not cover cosmetic damage, that doesn’t hinder normal operation of the device.
  4. CONDTROL GmbH reserves the right to decide on replacement or repair of the device.
  5. Other claims not mentioned above, are not covered by the warranty.
  6. After holding warranty works by CONDTROL GmbH warranty period is not renewed or extended.
  7. CONDTROL GmbH is not liable for loss of profit or inconvenience associated with a defect of the device, the rental cost of alternative equipment for the period of repair.
    This warranty applies to German law except provision of the United Nations Convention on contracts for the international sale of goods (CISG).

In the warranty case please return the device to retail seller or send it with defect description to the following address:
CONDTROL GmbH Wasserburger Strasse 9 84427 Sankt Wolfgang Germany

Documents / Resources

| CONDTROL Fliesen 3D Laser Cross Line Laser [pdf] User Manual
Fliesen 3D Laser Cross Line Laser, Fliesen 3D Laser, Cross Line Laser, Line Laser, Laser
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals