Congratulations on your purchase of laser distance meter Vector 60/80 CONDTROL. Safety instructions can be found in the end of this user manual and should be carefully read before you use the product for the first time.

SAFETY REGULATIONS

The user manual should be read carefully before you use the product for the first time. Unintended use of the product can be dangerous for human’s health and cause serious injury. Keep this user manual. If the product is given to somebody for temporary use, be sure to enclose user manual to it.

  • Do not misuse the product
  • Do not remove warning signs and protect them from abrasion, because they contain information about safe operation of the product. The device belongs to laser product class 2 in accordance with EN60825-1.

Laser radiation! Do not stare into beam Class 2 laser <1 mW 635nm EN60825-1: 2007-03

  • Do not look into the laser beam or its reflection, with unprotected eye or through an optical instrument. Do not point the laser beam at people or animals without the need. You can dazzle them.
  • To protect your eyes close them or look aside.
  • It is prohibited to disassemble or repair the product yourself. Entrust product repair to qualified personnel and use original spare parts only.
  • Do not use the product in explosive environment, close to flammable materials.
  • Avoid heating the batteries to avoid the risk of explosion and electrolyte leakage. In case of liquid contact with skin, wash it immediately with soap and water. In case of contact with eyes, flush with clean water during 10 minutes and consult the doctor.

INTENDED USE

Laser distance meters Vector 60 and Vector 80 are intended to measure distance, to calculate area and volume of measured objects, perform calculations by tilt sensor and Pythagoras’ Theorem, point to point measurements, store results of measurement/calculation in memory and also transmit via Bluetooth. The product is suitable for use at both indoor and outdoor building areas.
*-Vector 80 only.

DELIVERY PACKAGE

The delivery package includes:

  1. Laser distance meter – 1pc.
  2. Carry pouch with a strap – 1 pc.
  3. User manual – 1 pc.
  4. USB charger – 1 pc.

TECHNICAL SPECIFICATIONS

| Vector 60| Vector 80
---|---|---
Measuring range*| 0.05–60 m| 0.05–80 m
Measuring accuracy **| ± 1.5 mm
Smallest unit displayed| 1 mm
Display backlight| +
Reference point| Front, rear, tripod, end-piece
Continuous measurement (tracking)|

Max./min. value| +
Addition/subtraction| +
Area/ volume| +
Calculations by Pythagoras’ Theorem|

Bluetooth| +
Wall surface| –| +
Calculation of horizontal distance by tilt sensor|

|

Point to point measurement|

|

Memory| up to 30 values
Laser| Class II, 635 nm, <1 mW
Operating temperature| 0 °С … +40 °С
Storage temperature| –20 °С … +60 °С
Dust and water protection|

IP54

Power supply

| 3.7 V 850 mAh Li-ion rechargeable battery
Dimensions| 1194628 mm
Weight| 0.1 kg

  • Use a reflective plate to increase the measurement range during daylight or if the target has poor reflection properties.
  • Accuracy can decrease in unfavorable conditions, such as intense sunshine or when measurements are made against glossy or transparent surfaces, moving objects, objects with rough surface.
    In unfavourable conditions or when measured distance is over 100 m the maximum permissible accuracy is calculated in the following way: ± (Y + 0,25хDх10-3) mm, where D (mm) – measured distance Y (mm) – permissible accuracy according to technical data.

PRODUCT DESCRIPTION

CONDTROL-Vector-60-80-Laser-Distance-Meter-fig-1

  1. Display
  2. Keyboard
  3. A hole for the strap
  4. End-piece
  5. Tripod thread 1/4’’
  6. Mini-USB connector for charging

Functions of buttons

Button Short press Long press

Switch on the device

|

Switch on laser beam

| Continuous measurement (tracking)
Single distance measurement|
| Area

Wall surface* Volume

Tilt sensor* Pythagoras 1

Pythagoras 2

Pythagoras 3 Point to point*

|

Memory

|

Addition/ subtraction

|

Select reference point

|

Stop measurement/ clear/exit the mode

|

Switch off the device

simultaneously

|

Select measuring unit

|

  • Vector 80 only

Display

CONDTROL-Vector-60-80-Laser-Distance-Meter-fig-7

  1. Main line for displaying measuring results
  2. Additional lines for displaying measuring results
  3. Indication of tilt angle
  4. Indication of the mode
  5. Indication of point to point function
  6. Indication of Bluetooth
  7. Indication of battery charge level
  8. Indication of max/min values
  9. Indication of reference point
  10. Indication of measuring unit
  11. Indication of memory

OPERATION

Battery charging
Charge level is shown on display. Charge the battery when

symbol appears on the display. Use USB charger delivered in the set only. It is not recommended to use the product while charging. It takes approximately 3 hours to fully charge the batteries.

Switch on/off the device
To switch on the device short press . To switch off the device press and hold during 1 second

Measuring unit
Short press and simultaneously to enter service settings. Short press button to select required measuring unit – m/ft/in (meters/feet/inches). Short press to confirm and return to single distance measurement mode.

Reference point
Press and hold button for 1 second to select the reference point. The appropriate indicator will appear on the display.CONDTROL-Vector-60-80
-Laser-Distance-Meter-fig-9

Measurements

Single distance measurement

Short press The device will switch on.
Short press Laser beam will switch on.

Point the laser beam at the object of measurement.

Short press| Make a single distance measurement.
CONDTROL-Vector-60-80-Laser-Distance-Meter-fig-10– Measurement result
Short press| Delete the last measurement result.

Continuous distance measurement (Tracking)

Press and hold during

2 seconds

| The device will start making measurements one after another, showing current measurement result in the main line, maximal value in the 1st line, minimal value in the 2nd line.
---|---
CONDTROL-Vector-60-80-Laser-Distance-Meter-fig-11

– Angle value

– Maximal value

– Minimal value

– Current value

Press                or| Stop continuous measurement.

The last measured values are shown on the display.

Addition/subtraction

Short press| Turn on laser beam.

Aim the product at measured object.

---|---
Short press| Take first measurement.

Measuring result appears in the main line.

Short press __| The symbol of addition/subtraction will appear on the display.
Short press| Turn on laser beam. 1st measuring result moves to the line 2 on the display.
Short press|

Take 2nd measurement.

– 1st measurement

– 2nd measurement

– result of addition /subtraction

To do addition/subtraction of more than 2 measurements short press and perform the above mentioned operations required number of times.
Short press| Exit the mode.

CALCULATIONS

Area

Short press 1 time. Symbol will appear on the display. Laser beam will be on.
Short press Make the 1st measurement (length).
Short press Make the 2nd measurement (width). Area (length and width

multiplication) will be calculated and appear in the main line on the display.
CONDTROL-Vector-60-80-Laser-Distance-Meter-fig-14– Length

– Width

– Area

Short press | Exit the mode.

Wall surface (Vector 80 only)

Short press

2 times.

| Symbol will appear on the display. Laser beam will be on.
---|---
Short press| Make the 1st measurement (height).
Short press| Make the 2nd measurement (length 1).
– Height

– Length 1

– Area


Short press| Make the 3rd measurement (length 2)

– Height

– Length 2

– Wall area

3rd, 4th, 5th etc. measurements can be done unlimited number of times. Each new wall surface is added to previously calculated wall area result.
Short press| Exit wall area calculation mode.

Volume

Short press 2 times.

(Vector 60)

| Symbol                  will appear on the display. Laser beam will be on.
---|---
Short press 3 times.

(Vector 80)

|
Short press | Make (length).| the| first| measurement
Short press | Make the 2nd measurement (width).

– Length

– Width

– Area

Short press| Make the 3rd measurement (height).
– Width

–  Height

– Volume

Short press | Exit the mode.

  • Calculation of horizontal distance with the help of tilt sensor (Vector 80 only)
    Short press

4 times.

| Symbol   will appear on the


display. Laser beam will be on.

---|---
Short press | ****

Take 1st measurement (hypotenuse).





– tilt angle value (measured)

**** – hypotenuse (measured)

**** – vertical distance (calculated)

**** – horizontal distance (calculated)

Short press| Exit the mode.

  • Calculation of distance by 2 additional measurements (Pythagoras 1)
    Short press 3 times.

(Vector 60)

| Symbol| ****| will appear on display.
---|---|---|---
Laser beam is on.
Short press 5 times.

(Vector 80)

|
Short press | Make       the (hypotenuse).| 1st| measurement
Short press | Make  the

(cathetus 1).

| 2nd| measurement


****– Hypotenuse

– Cathetus 1

**** – Cathetus 2

Short press| Exit the mode.

  • Calculation of distance by 3 additional measurements – sum of cathetuses (Pythagoras 2)
    Short press| Symbol             will appear on display.
    ---|---
    4 times.|
    (Vector 60)| Laser beam is on.
    Short press|
    6 times.|
    (Vector 80)|

Short press

| Make       the (hypotenuse 1).| 1st| measurement
Short press| Make  the

(cathetus).

| 2nd| measurement
Short press| Make  the

(hypotenuse 2).

| 3rd| measurement

– cathetus (measured)

– hypotenuse 2 (measured)

– cathetus (calculated)

Short press| Exit the mode.

  • Calculation of distance by 3 additional measurements – subtraction of 2 catheters (Pythagoras 3)
    Short press| Symbol                   will appear on the
    ---|---
    5 times.|
    (Vector 60)| display. Laser beam is on.
    Short press|
    7 times.|
    (Vector 80)|
    Short press| Make       the (hypotenuse 1).| 1st| measurement
    Short press| Make  the

(hypotenuse 2).

| 2nd| measurement
Short press| Make  the

(cathetus).

| 3rd| measurement
CONDTROL-Vector-60-80-Laser-Distance-Meter-fig-26

**** – hypotenuse 2 (measured)

**** – cathetus (measured)

**** – cathetus (calculated)

Short press| Exit the mode.

  • Point-to-point measurement (Vector 80 only)
    Short press

8 times.

| Symbol will appear on display. Laser beam is on.
---|---
Short press | ****

Make the 1st measurement (distance to point A).

Short press | ****

Make          the          2ndmeasurement (distance to point B).

CONDTROL-Vector-60-80-Laser-Distance-Meter-fig-28– distance to point A (measured)

– distance to point B (measured)

– distance between points A and B (calculated)

Short press| Exit the mode.

Memory


Long press for 1 sec.

| Enter memory. A number of saved measurement/calculation results is

reflected on symbol   on the

display.

---|---
Short press __ | View saved measurement/ calculation results.
Short press| Exit the mode.

Bluetooth
Bluetooth function is always on by default. Symbol is permanently shown on the display. Activate Bluetooth in the smartphone, tablet PC or laptop. For further operation use application Smart Measure CONDTROL.

MESSAGE CODES
While operating, the following codes/symbols may appear on the display:

Message Problem Solution
301 Distance is out of range. Keep in permissible measuring range.
302 Reflected signal is too weak. Use a reflective plate.
303 Measuring result cannot be displayed (negative or exceeds 99999). Repeat

measurements until you get positive/ smaller measurement rerult.
304| Pythagorean theorem calculation error.| Make measurements in correct succession.
305| Low battery.| Charge the battery.
306| Temperature is too low.| Warm up the device to operating temperature.
307| Temperature is too high.| Cool down the device to operating temperature.
308| Ambient light is too strong.| Make measurements in less illuminated zone.

CARE AND MAINTENANCE

Attention! The instrument is a precise device and requires careful handling. The following recommendations will extend the life of the product:

  • Do not point the product at the sun.
  • Protect the product from bumps, falls, and excessive vibration; do not let liquids, construction dust and foreign objects get inside the product.
  • Do not expose the product to extreme temperatures.
  • If liquids get inside the product first remove the batteries, then contact the service center.
  • Do not store or use the product under high humidity conditions for a long time.
  • Clean the product with a soft wet cloth.
  • Keep device optics clean and protect it from mechanical damage.
  • Сarry out control measurements occasionally, especially if the product is subject to excessive mechanical or another impact, before and after taking important measurements.

UTILIZATION
Expired tools, accessories, and packages should be passed for waste recycle. Please send the product to the following address for proper recycling:

CONDTROL GmbH Wasserburger Strasse 9 84427 Sankt Wolfgang Germany  Do not throw the product in municipal waste! According to European Directive 2002/96/ЕC expired measuring tools and their components must be collected separately and submitted to environmentally friendly recycle of wastes.

WARRANTY

All CONDTROL GmbH products go through post-production control and are governed by the following warranty terms. The buyer’s right to claim about defects and general provisions of the current legislation do not expire.

  1. CONDTROL GmbH agrees to eliminate all defects in the product, discovered during the warranty period, that represent the defect in material or workmanship in full volume and at its own expense.
  2. The warranty period is 36 months and starts from the date of purchase by the end customer (see the original supporting document).
  3. The warranty cover defects resulting from wear and tear or improper use, malfunction of the product caused by failure to observe the instructions of this user manual, untimely maintenance and service and insufficient care, and the use of non-original accessories and spare parts. Modifications in the design of the product relieve the seller from responsibility for warranty works. The warranty did not cover cosmetic damage, which hinders the normal operation of the product.
  4. CONDTROL GmbH reserves the right to decide on the replacement or repair of the device.
  5. Other claims not mentioned above, are not covered by the warranty.
  6. After holding warranty works by CONDTROL GmbH warranty period is not renewed or extended.
  7. CONDTROL GmbH is not liable for loss of profit or inconvenience associated with a defect of the device, the rental cost of alternative equipment for the period of repair. This warranty applies to German law except the provision of the United Nations Convention on contracts for the international sale of goods (CISG). In warranty case please return the product to retail seller or send it with the defect description to the following address:
    • CONDTROL GmbH
    • Wasserburger Strasse 9
    • 84427 Sankt Wolfgang
    • Germany

References