CONDTROL IR-T1 Infrared Thermometer User Manual
- June 3, 2024
- CONDTROL
Table of Contents
CONDTROL IR-T1 Infrared Thermometer
Congratulations on your purchase of infrared thermometer IR-T1
CONDTROL.
Safety instructions given in this user manual should be carefully read before
you use the product for the first time.
SAFETY REGULATIONS
Attention
This user manual is an essential part of this product.
The user manual should be read carefully before you use the product for the
first time. If the product is given to someone for temporary use, be sure to
enclose user manual to it.
- Do not misuse the product
- Do not remove warning signs and protect them from abrasion, because they contain information about safe operation of the product.
Laser radiation!
Do not stare into beam
Class 2 laser
<1 mW 635-670nm
EN60825-1: 2007-03
- Do not look into the laser beam or its reflection, with unprotected eye or through an optical instrument. Do not point the laser beam at people or animals without the need. You can dazzle them.
- To protect your eyes close them or look aside.
- Do not let unauthorized people enter the zone of product operation.
- Store the product beyond reach of children and unauthorized people.
- It is prohibited to disassemble or repair the product yourself. Entrust product repair to qualified personnel and use original spare parts only.
- Do not use the product in explosive environment, close to flammable materials.
- Avoid heating the batteries to avoid the risk of explosion and electrolyte leakage. In case of liquid contact with skin, wash it immediately with soap and water. In case of contact with eyes, flush with clean water during 10 minutes and consult the doctor.
FUNCTIONS/APPLICATIONS
IR-thermometer IR-T1 CONDTROL is designed for non-contact measurement of surface temperature of various objects. Ergonomic, shockproof housing, small size and weight, intuitive interface, laser spot marking, continuous measurement mode provide simple and convenient measurement of temperature of dangerous, moving, hard-to-reach distant objects at less than 1 second at just one touch of the trigger. The principle of non-contact temperature measurement is based on measuring of the intensity of infrared radiation of the object’s surface.
DELIVERY PACKAGE
- Infrared thermometer – 1pc.
- Battery (1,5V LR6 AA) – 1 pc.
- User manual – 1 pc.
TECHNICAL SPECIFICATIONS
Display | 30*30mm LCD with backlight |
---|---|
Measuring range | -50 °C …600 °C |
-58 °F …1112 °F
| -50 °C…-20 °C| ±3 °C (±6 °F)
Accuracy| (-58 °F…-4 °F)|
| -20 °C…0 °C| ±2 °C (±4 °F)
| (-4 °F…32 °F)|
| 0 °C…600 °C| ±1,5 °C (±3 °F) or ±1,5%
| (32 °F…1112 °F)|
Smallest unit displayed| 0.1 °C/°F
Optical resolution| 12:1
Response time| 0,1 sec
Spectral sensitivity| 8…14 µm
Emissivity| 0.1…1.00 adjustable
Operating temperature| 0 °С …50 °С (32 °F…122 °F)
Storage temperature| -10°С…60°С (-14 °F…140 °F)
Relative humidity for operation and storage| <95%
Power supply| 1,5V LR6 АА alkaline
Battery life| ~6 hours
Automatic shutdown| 30 sec.
Laser| Class II, 635-670nm, <1mW
Dimensions| 1654759mm
Weight| 135 g
PRODUCT DESCRIPTION
- Display
- Keyboard
- Trigger
- Laser spot marking exit window
- Infrared sensor
- Battery cover 1
Display
- Indication of continuous measurement
- Emissivity value
- Indication of battery charge level
- Measuring units (°С or °F)
- Maximal/minimal measurement value
- Indication of maximal/minimal value
- Indication of display backlight
- Indication of activated laser spot marking
- Measurement result
- Indication of data hold on the display
Keyboard
-
Check max/min values/adjust emissivity degree
-
Switch on/off display backlight and laser spot marking
-
Select measuring unit (°С or °F)/adjust emissivity degree
INSTALL/REPLACE BATTERIES
Remove the
battery cover. Install the battery observing correct polarity. Put the battery
cover back and push it until a click is heard. If the symbol of low battery
change level appears on the display, replace the battery by a new one.
SWITCH ON/OFF
Short press the trigger to switch on the device. The device is ready to work.
The device switches off automatically in 30 seconds after the last pressing on
any button.
SETTINGS
-
Measuring units
Short press button to select the measuring unit:- °C – degrees Celsius;
- °F – degree Fahrenheit.
Short press button to select the measuring unit.
-
Laser spot marking
Short press buttonto activate laser spot marking*. Symbol will appear on the display. To disable laser spot marking short press button several times until symbol disappears. Laser spot marking is only used for aiming and can be switched off when working at short distance to save battery power.- Laser spot marking is on as long as the trigger is pressed.
-
Display backlight
Short press buttonto switch on display backlight.
Symbol will appear on the display.
To switch off the backlight short press button several times until backight
is switched off and symbol disappears.
MEASUREMENT
Short press the trigger to switch on the device. Press corresponding buttons
to set the measuring unit, activate laser sport marking, display backlight if
needed. Aim the device against the object of measurement and press the
trigger. Measurement result will appear on the display. Long press the trigger
to activate continuous measurement. Indication SCAN will appear on the
display. To finish continuous measurement release the trigger. Indication of
data hold HOLD will appear on the display. Measurement result as well as the
minimum/maximum value will also be displayed. Short press button several times. The minimum and
maximum values are displayed alternately on the display.
EMISSIVITY
All objects emit thermal energy. Emitted energy quantity depends on the
surface temperature and object emissivity. The product can measure emission on
the surface of object and calculate object temperature. Objects with different
surfaces but with the same temperature can emit different quantity of thermal
energy. Many objects (e.g. coated metal, wood, water, skin and texture)
possess high emissivity (0,9 and more), and emit more energy than glossy
surfaces and uncoated metal, because their emissivity is less than 0,6.
Adjustment of emissivity helps to take this feature into consideration and
minimize inaccuracy of temperature measurement.
Material | Emissivity | Material | Emissivity |
---|---|---|---|
Asphalt | 0.90~0.98 | Black cloth | 0.98 |
Concrete | 0.94 | Human skin | 0.98 |
Cement | 0.96 | Bubble | 0.75~0.80 |
Sand | 0.90 | Charcoal dust | 0.96 |
Soil | 0.92~0.96 | Paint | 0.80~0.95 |
Water | 0.92~0.96 | Matte paint | 0.97 |
Ice | 0.96~0.98 | Black rubber | 0.94 |
Snow | 0.83 | Plastic | 0.85~0.95 |
Glass | 0.90~0.95 | Wood | 0.90 |
Ceramic | 0.90~0.94 | Paper | 0.70~0.94 |
Marble | 0.94 | Chromic oxide | 0.81 |
Gypsum | 0.80~0.90 | Copper oxide | 0.78 |
Mortar | 0.89~0.91 | Ferric oxide | 0.78~0.82 |
Brick | 0.93~0.96 | Texture | 0.90 |
Switch on the device.
Press and hold the trigger, then long press button Symbol will start flashing on the display.
Release the trigger. Value 0.95 is set by default.
Press buttonsand to
adjust the emission degree. In 5 seconds the emission degree will be fixed on
the display, symbol will stop flashing.
OPTICAL RESOLUTION
As the distance from the device to the object increases, the size of the measured spot on object surface increases accordingly. To determine the size of the spot (S) divide the distance from the device to the target (D) by 12.
CARE AND MAINTENANCE
Attention
The product is an accurate optical mechanic device and requires careful
handling. Maintenance of the following recommendations will extend the life of
the device:
- Keep the product clean and protect it from any bumps, dust and dampness; do not allow moisture, dust or other dirt get inside of the product.
- Do not expose the product to extreme temperatures.
- If liquids get inside the product first remove the batteries, then contact a service center.
- Do not store or use the product under high humidity conditions for a long time.
- Clean the product with soft wet cloth.
- Keep the device optics clean and protect it from mechanical impact. Failure to observe the following rules may result in leakage of electrolyte from the batteries and damage the device:
- Remove the batteries from the product if you do not use it for a long time.
- Do not leave discharged batteries in the device.
UTILIZATION
Expired tools, accessories and package should be passed for waste recycle.
Please send the product to the following address for proper recycle:
CONDTROL GmbH
Wasserburger Strasse 9
84427 Sankt Wolfgang
Germany
Do not throw the product in municipal waste!
According to European directive 2002/96/ЕC expired measuring tools and their
components must be collected separately and submitted to environmentally
friendly recycle of wastes.
WARRANTY
All CONDTROL GmbH products go through post-production control and are governed by the following warranty terms. The buyer’s right to claim about defects and general provisions of the current legislation do not expire.
- CONDTROL GmbH agrees to eliminate all defects in the product, discovered while warranty period, that represent the defect in material or workmanship in full volume and at its own expense.
- The warranty period is 24 months and starts from the date of purchase by the end customer (see the original supporting document).
- The warranty doesn’t cover defects resulting from wear and tear or improper use, malfunction of the product caused by failure to observe the instructions of this user manual, untimely maintenance and service and insufficient care, the use of non-original accessories and spare parts. Modifications in design of the product relieve the seller from responsibility for warranty works. The warranty does not cover cosmetic damage, that doesn’t hinder normal operation of the product.
- CONDTROL GmbH reserves the right to decide on replacement or repair of the device.
- Other claims not mentioned above, are not covered by the warranty.
- After holding warranty works by CONDTROL GmbH warranty period is not renewed or extended.
- CONDTROL GmbH is not liable for loss of profit or inconvenience associated with a defect of the device, rental cost of alternative equipment for the period of repair.
This warranty applies to German law except provision of the United Nations Convention on contracts for the international sale of goods (CISG).
In warranty case please return the product to retail seller or send it with
description of defect to the following address:
CONDTROL GmbH
Wasserburger Strasse 9
84427 Sankt Wolfgang
Germany
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>