Acuity Brands Legacy DSX1 LED Area Luminaire Instruction Manual

June 9, 2024
Acuity Brands

Acuity Brands Legacy DSX1 LED Area Luminaire Instruction Manual

Acuity Brands Legacy DSX1 LED Area Luminaire.jpg

READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

  • To reduce the risk of death, personal injury or property damage from fi re, electric shock, falling parts, cuts/ abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
  • Installation and service of luminaires should be performed by a qualifi ed licensed electrician.
  • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
  • It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
  • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confi rm. Any part damaged or broken during or after assembly should be replaced.
  • Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.

FIG 2 WARNING.JPG

CAUTION: RISK OF PRODUCT DAMAGE

  • Never connect components under load.

  • Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.

  • Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy sensors, timing devices, or other related control devices. LED fixtures must be powered directly off a switched circuit.

  • Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection
    or conduction cooling.

  • Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.

  • Only use fixture in its intended location.

  • LED products are Polarity Sensitive. Ensure proper Polarity before installation.

  • Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.

  • Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.

  • Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.

  • Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.

Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements.

Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.

Our Brands

Indoor/Outdoor
Lithonia Lighting
Carandini
Holophane
RELOC
Light Concepts

Indoor Lighting
Gotham
Mark Architectural Lighting

Peerless
Renaissance Lighting

Winona Lighting

Outdoor Lighting

American Electric Lighting

Antique Street Lamps

Hydrel
Tersen

Controls
DARK TO LIGHT
LC&D
ROAM
Sensor Switch
Synergy

Daylighting
SunOptics

Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.

ABL LED General Warnings, Form No. 503.203
© 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10

Installation Instructions
D-series G1 nLight Air Retrofit Door
DELIVERY: Upon receipt of package, thoroughly inspect for any freight damage. All damage should be reported to the delivery carrier. Compare the catalog description listed on the packing slip with the fi xture label on the inside of the housing to be sure you have received the correct merchandise.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Tools Required: 1/4″ socket wrench. 3/16″ allen wrench.

Link to installation video

FIG 1 Installation Instructions.JPG

1. Open doorframe by loosening the (2) captive screws using 3/16″ allen wrench (Figure 1).

FIG 3.JPG

FIG 4.JPG

FIG 6.JPG

FIG 7.JPG

6. Replace each individual wire unattached from the wire connector in step 5 with the corresponding color wire from the new replacement door (black for black; white for white; red for red; grey for grey; purple for purple). See Figure 5.

Repeat steps 5 and 6, one wire at a time, until all 5 wires are connected from the fi xture to the new replacement door.

FIG 8.JPG

7. Close doorframe by tightening the (2) captive screws using 3/16″ allen wrench (Figure 1) to 30-35 in lbs.

Recycle original door as required by local code.

Lithonia Lighting Outdoor • One Lithonia Way • Conyers, Georgia 30012
Phone: 800-279-8041 • Fax: 770.918.1209 • www.lithonia.com
© 2014 Acuity Brands Lighting, Inc. All rights reserved.

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Acuity Brands User Manuals

Related Manuals