Acuity Brands Legacy DSX0 LED Area Luminaire Instruction Manual
- June 9, 2024
- Acuity Brands
Table of Contents
LED IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/ abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING RISK OF ELECTRIC SHOCK
Disconnect or turn off power before installation or servicing.
Verify that supply voltage is correct by comparing it with the luminaire label
information.
Make all electrical and grounded connections in accordance with the National
Electrical Code (NEC) and any applicable local code requirements.
All wiring connections should be capped with UL approved recognized wire
connectors.
WARNING RISK OF BURN
Allow lamp/fixture to cool before handling. Do not touch enclosure or light
source.
Do not exceed maximum wattage marked on luminaire label.
Follow all manufacturer’s warnings, recommendations and restrictions for:
driver type, burning position, mounting locations/methods, replacement and
recycling.
CAUTION RISK OF INJURY
Wear gloves and safety glasses at all times when removing luminaire from
carton, installing, servicing or performing
maintenance.
Avoid direct eye exposure to the light source while it is on.
CAUTION RISK OF FIRE
Keep combustible and other materials that can burn, away from lamp/lens.
Do not operate in close proximity to persons, combustible materials or
substances affected by heat or drying.
CAUTION: RISK OF PRODUCT DAMAGE
Never connect components under load.
Do not mount or support these fixtures in a manner that can cut the outer
jacket or damage wire insulation.
Unless individual product specifications deem otherwise: Never connect an LED
product directly to a dimmer packs, occupancy sensors, timing devices, or
other related control devices. LED fixtures must be powered directly off a
switched circuit.
Unless individual product specifications deem otherwise: Do not restrict
fixture ventilation. Allow for some volume of airspace around fixture. Avoid
covering LED fixtures with insula on, foam, or other material that will
prevent convection or conduction cooling.
Unless individual product specifications deem otherwise: Do not exceed
fixtures maximum ambient temperature.
Only use fixture in its intended location.
LED products are Polarity Sensitive. Ensure proper Polarity before
installation.
Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding
equipment must be worn during all installation or servicing of the unit.
Do not touch individual electrical components as this can cause ESD, shorten
lamp life, or alter performance.
Some components inside the fixture may not be serviceable. In the unlikely
event your unit may require service, stop using the unit immediately and
contact an ABL representative for assistance.
Always read the fixtures complete installation instructions prior to
installation for any additional fixture specific warnings.
Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visitwww.acuitybrands.com.
Our Brands
Indoor/Outdoor
Lithonia Lighting
Carandini
Holophane
RELOC
Light Concepts
Indoor Lighting
Gotham
Mark Architectural Lighting
Peerless
Renaissance Lighting
Winona Lighting
Outdoor Lighting
American Electric Lighting
Antique Street Lamps
Hydrel
Tersen
Controls
DARK TO LIGHT
LC&D
ROAM
Sensor Switch
Synergy
Daylighting
SunOptics
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
Installation Instructions
D-series G1 nLight Air Retrofit Door
DELIVERY: Upon receipt of package, thoroughly inspect for any freight damage. All damage should be reported to the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the inside of the housing to be sure you have received the correct merchandise.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Tools Required: 1/4″ socket wrench. 3/16″ allen wrench.
Link to installation video
1. Open doorframe by loosening the (2) captive screws using 3/16″ allen wrench (Figure 1).
Figure 1
2. Compare the description on the label of the original door to the
description on the label of the new replacement (4) door.
a) The new door description will match the text of the original door
description plus “NLTAIR2 PIRHNRD”.
b) Next, compare the Watts (1) , Volts (2) , and Pri Amps (3)
between the 2 labels. These numbers should match.
LABEL ON ORIGINAL DOOR
LABEL ON NEW REPLACEMENT DOOR
3. Using ¼” hex socket loosen (2) screws to remove hinge bracket. (Figure 2) Then lift door until it releases from the hinge-pin.
Figure 2
4. Replace original door with new replacement door and retighten (2) screws to 30-35 in lbs.
5. Fixture wiring:
The photocell receptacle (Figure 3), with the shorting cap, stays installed in
the fixture head.
Two of the wires (brown, orange) are already capped. Leave them capped.
Remove one of the five individual wires (black, white, red, grey and purple) exiting the photocell receptacle from the wire connector and cap it off with the provided 2-slot wire connectors (Figure 4). Use one slot only, the second slot remains empty. Proceed to step 6, one wire at a time, for each of the five individual wires.
Figure 3 Figure 4
6. Replace each individual wire unattached from the wire connector in step 5 with the corresponding color wire from the new replacement door (black for black; white for white; red for red; grey for grey; purple for purple). See Figure 5.
Repeat steps 5 and 6, one wire at a time, until all 5 wires are connected from the fixture to the new replacement door.
Figure 5 Figure 5 Wiring Diagram
7. Close doorframe by tightening the (2) captive screws using 3/16″ allen wrench (Figure 1) to 30-35 in lbs.
Recycle original door as required by local code.
©2010 Acuity Brands Lighting, Inc. All Rights Reserved. 7/14
Lithonia Lighting Outdoor • One Lithonia Way • Conyers, Georgia 30012
Phone: 800-279-8041 • Fax: 770.918.1209
• www.lithonia.com
© 2014 Acuity Brands Lighting, Inc. All rights reserved.
Part Number:
RJ521504 Rev B
Revision Date: 8/1/22
References
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- U.S. Environmental Protection Agency | US EPA
- Lithonia Lighting® | Best Value in Lighting
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>