DETEX CS900 Remote Alarm Instruction Manual
- June 4, 2024
- DETEX
Table of Contents
DETEX CS900 Remote Alarm Instruction Manual
Induction
AC Adapter P/N (CS2900 Only): 103985-1: Install wires to terminal block.
Striped Wire is (+).
CS900 / CS2900 Terminal Block Table
Functions|
Description
Ext 9V DC(+)Striped wire| DC Power Supply not supplied with CS900 products)
Ext 9V DC (—)
Loop Monitor| To Open Loop security device
Loop Return
Normally open contact.
Closed contacts sound alarm.
Recommended Wire Sizes
Wire Gauge|
Maximum Length of
Two Conductor Cable
22 AWG
| 50 Feet of twisted pair
20 AWG|
250 Feet of twisted pair
18 AWG
|
1000 Feet of twisted pair
Surface Installation
-
Press-In Anchors
P/N: 102642-3
Recommended drill size for anchors: 1/4″ diameter
NOTE: Also included are self-drilling screws -
Surface Backbox
P/N(s): 102649-1 (Gray)
102649-2 (Black) -
Cylinder Plug
P/N: 103799-7 -
Machine Screw, #6-32 x 2-1/8″
P/N: 102866-17
Flush Installation
Support
Detex Corporation, 302 Detex Drive,
New Braunfels, Texas
78130-3045 (830)629-2900
1-800-729-3839
Fax (830)620-6711
E-MAIL: detex@detex.com
INTERNET: www.detex.com