Important Safety Instructions
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions. Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING RISK OF ELECTRIC SHOCK
✓ Disconnect or turn off power before installation or servicing.
✓ Verify that supply voltage is correct by comparing it with the luminaire
label information.
✓ Make all electrical and grounded connections in accordance National
Electrical Code (NEC) and any applicable local code requirements.
✓ All wiring connections should be capped with UL approved recognized wire
connectors.
WARNING RISK OF BURN
✓Allow lamp/fixture to cool before handling.
✓ Do not touch enclosure or light source.
✓ Do not exceed maximum wattage marked on luminaire label.
✓ Follow all manufacturer’s warnings, recommendations and restrictions for:
driver type, burning position, mounting local code requirements.
locations/methods, replacement and recycling.
CAUTION: RISK OF PRODUCT DAMAGE
✓ Never connect components under load.
✓ Do not mount or support these fixtures in a manner that can cut the outer
jacket or damage wire insulation.
✓ Controls for dimming, auto-sensing, or remote control of a luminaire that
are not factory-wired to the luminaire must be checked for compatibility with
the luminaire prior to installation. LED fixtures must be powered directly o
ffa switched circuit.
✓ Unless individual product specifications deem otherwise: Do not restrict
fixture ventilation. Allow for some volume of airspace around fixture.
✓ Avoid covering LED fixtures with insulation, foam, or other material that
will prevent convection or conduction cooling.
✓ Unless individual product specifications deem otherwise: Do not exceed
fixtures maximum ambient temperature.
✓ Only use fixture in its intended location.
✓ LED products are Polarity Sensitive. Ensure proper Polarity before
installation. Electrostatic Discharge (ESD): ESD can damage LED fixtures.
Personal grounding equipment must be worn during all installation or servicing
of the unit.
✓ Do not touch individual electrical components as this can cause ESD, shorten
lamp life, or alter performance. Some components inside the fixture may not be
serviceable. In the unlikely event your unit may require service, stop using
the unit immediately and contact an ABL representative for assistance.
✓ Always read the fixtures complete installation instructions prior to
installation for any additional fixture specific warnings.
✓ Always ensure that the electrical distribution system is up to NEC (and any
applicable local code) requirements.
✓ Verify that power distribution system has proper grounding. Lack of proper
earth ground can lead to fixture failure and may void warranty.
Choose either Part 15 OR Part 18 and move to Page 3 Installation
Instructions under Delivery. Lithonia Outdoor will always use Part 15.
All luminaires that contain electronic devices that generate frequencies
above 9kHz from any component within the luminaire comply with Part 15 of the
FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference
(2) This device must accept any interference received, including
interference that may cause undesired operation
This device complies with Part 18 of the FCC Rules but may cause interference
with cordless and cell phones, radios, televisions, and other electronic
devices. To correct the problem, move the device away from the luminaire or
plug into a different outlet. This product may cause interference to radio
equipment and should not be installed near maritime safety communications
equipment or other critical navigation or communications equipment operating
between 0.45-30MHz.
Failure to follow any of these instructions could void product warranties.
For a complete listing of product Terms and Conditions, please
visitwww.acuitybrands.com.
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising
out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2021, 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service should be performed by a qualified licensed electrician.
- Maintenance should be performed by qualified person(s) familiar with the products’ construction and operation and any hazards involved. Regular maintenance programs are recommended.
- DO NOT INSTALL DAMAGED PRODUCT! This product has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING
RISK OF ELECTRIC SHOCK
✓ Disconnect or turn off power before installation or servicing.
✓ Verify that supply voltage is correct by comparing it with the luminaire
label information.
✓ Make all electrical and grounded connections in accordance with the National
Electrical Code (NEC) and any applicable local code requirements.
✓ All wiring connections should be capped with UL approved recognized wire
connectors.
CAUTION
RISK OF INJURY
✓ Wear gloves and safety glasses at all times when removing luminaire from
carton, installing, servicing or performing maintenance.
✓ Avoid direct eye exposure to the light source while it is on.
WARNING
RISK OF BURN
✓ Allow lamp/fixture to cool before handling. Do not touch enclosure or light
source
✓ Do not exceed maximum wattage marked on luminaire label.
✓ Follow all manufacturer’s warnings, recommendations and restrictions for:
driver type, burning position, mounting locations/methods, replacement and
recycling.
CAUTION
RISK OF FIRE
✓ Keep combustible and other materials that can burn, away from lamp/lens.
✓ Do not operate in close proximity to persons, combustible materials or
substances affected by heat or drying.
Always read the fixtures complete installation instructions prior to
installation for any additional fixture specific warnings.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
Important Safety Instructions
✓ Electrostatic Discharge (ESD): ESD can damage product(s). Personal
grounding equipment must be worn during all installation or servicing of the
unit.
✓ Do not touch individual electrical components as this can cause ESD and
affect product Performance.
✓ Do not stretch or use cable sets that are to short or are of insufficient
length.
✓ Do not tamper with contacts.
✓ Do not modify the product.
✓ Do not change or alter internal wiring or installation circuitry.
✓ Do not use product for anything other than its intended use.
✓ If installing latching springs: ensure that the springs are fully engaged
prior to moving to next connection. If installing wiring systems: Materials
and component parts of a manufacturing wiring system as described in Article
604 of the National Electric Code and Underwriters Laboratories Standard for
Safety #183 MUST BE installed.
Please see product specific installation instructions for additional warnings
or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties. For
a complete listing of product Terms and Conditions, please visit
www.acuitybrands.com.
Our Brands| Indoor/Outd oor| In door Lig hti ng|
Outdoor Lighting| Controls| Daylighting
---|---|---|---|---|---
Lithonia Lighting Carandini Holophane RELOC
Light Concepts| Gotham
Mark ArchitecturaI Lighting Peerless
Renaissance Lighting Winona Lighting
| American Electric Lighting Antique Street Lamps Hydrel
Tersen| DARK TO LIGHT LC&D
ROAM
Sensor Switch Synergy
| SunOptics
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2021, 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
Installation Instructions – Direct Wall S2PWD/S4PWD
A. Overview – Fixture
Do not join fixtures together on the floor.
NOTE: Illustrations are used for reference only and can differ slightly
from the actual lighting system installed. However, key components addressed
in this information are represented as accurately as possible.
WARNING: DO NOT LOAD SINGLE FEED TO MORE THAN 6 AMPS
B. Overview Mounting
Individual Fixture Configurations
INDIVIDUAL UNITS (MOUNTING)
LENGTH| “A” O.A.L| “B” O.C.| “C” FROM END
2FT| 2’- 0 9/16″| 1’- 1″| 5 3/4”
3FT| 3’- 0 9/16″| 2’- 1″| 5 3/4”
4FT| 4’- 0 9/16″| 3’- 1″| 5 3/4”
5FT| 5’- 0 9/16″| 4’- 1″| 5 3/4”
6FT| 6’- 0 9/16″| 5’- 1″| 5 3/4”
7FT| 7’- 0 9/16″| 6’- 1″| 5 3/4”
8FT| 8’- 0 9/16″| 7’- 1″| 5 3/4”
O.A.L – Overall length
O.C. – Distance from center to center IND FIXTURE
Run Configurations
RUN LAYOUT (MOUNTING)
“A1” O.A.L| “A2” O.A.L.| “B”| “C” FROM END| “D”
4′- 0 1/4″| 4′- 0″| 3′- 1″| 5 3/4″| 11″
5′- 0 1/4″| 5′- 0″| 4′- 1′”| 5 3/4 “| 11″
6′- 0 1/4″| 6′- o·| s·- r·| 5 3/ 4 “| 11·
7′- 0 1/4 “| 7′- o·| 6′- 1| 5 3/4″| 11″
8′- 0 1/4″| 8′- 0″| 7′- r·| 5 3/4″| 11″
Mounting Hardware:
Mounting rails are attached to each fixture section. Unscrew the mounting rails from the fixture to install rails to the wall first.
D. Set Up Wall
At power feed locations:
Mount the J-box on the wall at distanced 5-13/16” from the start of run. The
center line of J-box and luminaire run should align with each other.
Secure mounting rails for the first fixture per pattern/row layout. Leave approximately 1-1/4” space from edge of the wall to mount the rail for the first section.
Note: Contractor should provide blocking behind wall to adequately support fixture weight.
Level mounting rail to ensure proper mounting.
E. Mount Fixtures
All power connections should be installed according to local/national codes by a Certified Electrician.
Make wiring connections with wires from J-box
a. Slide top flange of mounting bracket underneath top flange of mounting
rail.
b. Rotate fixture toward wall until bottom flange of the mounting bracket
passes bottom flange of mounting rail.
c. While supporting fixture, rest bottom flange of the mounting bracket
on bottom flange of mounting rail.
d. Rotate fixture up toward wall and secure at mounting points with #8
screw provided.
F. Opening Fixture
Remove lens using appropriate tool (plastic putty knife recommended, or a similar tool) by placing tool between cast end and lens. Do not use sharp metal objects as a removal tool. Slowly pry lens away from fixture.
To remove the reflector unscrew four #8 screws
G. Join Sections (NOTE: Joining hardware parts provided in a separate red bag.)
Install (4x) aligner keys onto one end of the run. The bump on the aligner key should face the extrusion. Half of the aligner key should be exposed to insert into the next section.
a. Install (2x) slider aligners by sliding them into the appropriate slot
on one end of the run.
b. Slide joining fixture while keeping aligner keys and sliding aligners
aligned to the slots from opposite fixture body.
c. Fully join sections together (Detail “A” and Detail “B”).
NOTE: Pull wires into the next section before fully joining fixture together. From each quick connector provided on the intermediate ends of the fixture remove and discard the half (male or female) to which no wires are connected. Make electrical connections with connectors.
H. Close Fixtures
Insert reflectors into the housings.
Secure reflectors with #8 screws.
Gently push lens and snap it in into the housing.
NOTE: Use two people when working with fixtures greater than 4 feet.
Battery Pack/Test Switch (E10WLCP):
a. If battery pack option is selected (E10WLCP), then an un-switched
normal hot is required for power and sensing.
b. Standard battery drop is on the right side of the section with the
battery. See above diagram for location of test button.
For nLight option (NLIGHT):
Pull CAT5 cable through the knockout with the power cord and connect to the
nLight device within the fixture.
nLight AIR
NOTE: Install antenna on coax cable.
I. Supplemental
Wires used to power EMPACK.
NOTE: Cap the unused wire at the junction box.
Remote BGTD Mounting Option:
a. Suggested to mount in an accessible location for maintenance. To be
installed in ceiling or to structure according to local and NEC code.
b. 6 foot flexible conduit is attached. The remote BGTD should be mounted
within 6 feet of the J-box above the fixture.
J. Supplemental Continuous lens
a. Suggested to mount in an accessible location for maintenance. To be
installed in ceiling or to structure according to local and NEC code.
b. 6 foot flexible conduit is attached. The remote BGTD should be mounted
within 6 feet of the J-box above the fixture.
c. Unroll lens as you make your way through the run.
d. Follow “Right (R)” detail for lens cutting. Cut lens approximately
1/8″ longer than last section housing and tuck in right lens end into end cap
cavity.
NOTE: Use at least two people when installing a continuous lens.
NOTE: Continuous lens supplied oversized for any given run lengh.
Contractor to make final lenght cut at the time of installation.
NOTE: Continuous lens should stay at room temperature for a few hours
before installation.
J. Supplemental Wall Mounting Rails
Remove the cover where JB is using a flat head screw driver by inserting it in designated tabs. Pull wires and wire it in JB to power the fixture. Covers not in feed location should stay intact.
Bend tabs on the end as shown above for beginning of the run and end of run (first and last fixture). For intermediate fixtures remove tab by bending it and twisting as shown above on the right.
K. Contractor’s Resources
Check out helpful programs, tools, installation videos and more.
Customer Support
marklighting.com I 800-705-SERV (7378) I TechSupport- Mark@AcuityBrands.com I © 2022 AcuityBrands Lighting, Inc. All Rights Reserved. We reserve the right to change design, materials and finish in any way that will not alter installed appearance or reduce function and performance.
References
- Mark Architectural Lighting | Acuity Brands
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- U.S. Environmental Protection Agency | US EPA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>