TRIDONIC LED Light Engine, LED Flexible
Preparation
Use ESD safety equipment!
For details see ESD-Guideline on: www.tridonic.com
Don‘t expose the LLE-FLEX EXC2 to tensile or compressive stresses. Prevent
shear- or peel forces.
Connection by soldering
Ensure insulation in the connection area against conductive surfaces.
Do not use excessive solder, soldering time max. 2 s at max. 275 °C. Keep the
stripping length of the connecting cables as short as possible.
Additional insulation by means of insulation foil ≥ 500 V in the connection
area is recommended.
Connection with ACL Connector Plug (only for tape with 8 mm width)
Remove the liner of the adhesive tape in the area of the connection pads (min.
5 mm).
Slide the ACL Connector onto the LLE-FLEX EXC2 and lock it by pressing the
connector together firmly.
Check if the ACL Connector is closed properly to ensure a reliable connection.
Cutting the LLE-FLEX EXC2
To separate the LLE-FLEX EXC2 cut left or right (depending on the connection
direction) from the soldering pad.
Use a sharp tool such as an electronic side cutter or scissors.
Additional insulation by means of insulation foil ≥ 500 V at the end of the
tape is recommended.