RAB Lighting SLIM17 FA 15-30W Field-Adjustable Wall Pack Instructions
- June 9, 2024
- RAB Lighting
Table of Contents
INSTRUCTIONS
SLIM® 17 FA 15-30W
FIELD-ADJUSTABLE WALL PACK INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com
SLIM17 FA 15-30W
SLIM17 FA 15-30W Field-Adjustable Wall Pack
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR
FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and
all applicable local codes. Proper grounding is required for safety. THIS
PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE
BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND
THE HAZARDS INVOLVED.
Min 90 °C SUPPLY CONDUCTORS.
WARNING: Make certain power is OFF before installing or maintaining
fixture. No user serviceable parts inside.
WARNING: Do not use an electric generator to test LED fixtures. CAUTION:
For proper weatherproofing function, all gaskets must be seated properly and
all screws inserted and tightened. This is important with an uneven wall
surface. Silicone all plugs and unused conduit entries. For wet location
compliance, fixture must be properly sealed. For moisture seal, apply silicone
caulking between the mounting surface and back housing, as well as around the
sides of the housing. This is important with uneven wall surface.
WALL MOUNT
Suitable for outdoor applications.
-
Using an Allen Wrench loosen (1) Screw on Housing side as shown in Fig. 1.
-
Open Housing Cover and rotate to a 90° angle as shown in Fig. 2.
-
Using a screwdriver loosen (1) Screw to remove Housing Back Plate from Housing as shown in Fig. 3, 4.
|
---|--- -
Using a drill open holes in Housing Back Plate as shown in Fig. 5.
-
Apply Foam Gasket (provided) to external surface of the Housing Back Plate by removing yellow plastic film and adhering to Housing Back Plate as shown in Fig. 6.
-
Feed supply wires through Housing Back Plate as shown in Fig. 7 and secure to junction box. Secure Housing Back Plate to surface or junction box (supplied by others) with Screws (supplied by others).
-
Wire the Housing leads to supply wires using UL listed wire connectors according to NEC and local codes (Fig. 13). Push all wires into the housing.
-
Mount the Housing over the Housing Back Plate and secure with Screw (provided) as shown in Fig. 8.
-
Lower Housing Cover and secure with (1) Screw using an Allen Wrench as shown in Fig. 1.
-
For Conduit wiring, remove Side Conduit Cap using a screwdriver as shown in Fig. 2. Feed supply wires through conduit opening with a suitable connector. Wire the Housing leads to supply wires using UL listed wire connectors according to NEC and local codes (Fig. 13). Push all wires into the housing. Follow mounting instructions.
|
---|---
0° – 90° ANGLE ADJUSTMENT
-
Using an Allen Wrench loosen (1) Screw on Housing side as shown in Fig. 9.
-
Fixture angle is adjustable from 0° (Full Cutoff) to 90°.
-
Adjust Housing Cover to desired angle as shown in Fig. 10. settings at 15° each. Secure with (1) Screw using an Allen Wrench.
FIELD ADJUSTMENT
Follow instructions below to change fixture Color Temperature (CCT) from the factory settings.
Factory Settings: 4000K
-
Using an Allen Wrench loosen (1) Screw on Housing side as shown in Fig. 11.
-
Lift Housing cover and locate CCT Selector Switch in Housing as shown in Fig. 12.
-
Select Color Temperature (CCT) by sliding the CCT Selector Switch to the desired value.
-
Lower Housing Cover and secure with (1) Screw using an Allen Wrench as shown in Fig. 11.
0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V thru 277V, 50 or 60 Hz. For 0-10 Dimming, follow the wiring directions as in Fig. 13.
- Connect the Black/Brown fixture lead to the LINE supply lead.
- Connect the White/Blue fixture lead to the COMMON supply lead.
- Connect the Green/Yellow wire from the fixture to supply ground. Do NOT connect GROUND of the dimming fixture to the output.
- Connect the purple fixture lead to the DIM V+ lead.
- Connect the gray fixture lead to the DIM V- lead.
- Cap the yellow fixture lead, if present. Do NOT connect.
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.
- Clean polycarbonate lens with non-abrasive glass cleaning solution.
- Do not open the fixture to clean the LED. Do not touch the LED.
TROUBLESHOOTING
- Is the fixture grounded properly?
- It is recommended to wear gloves to avoid injury during installation.
- If any smoke or spark, please turn off the power immediately.
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
Easy Answers
© 2021 RAB LIGHTING Inc.
SLIM17 FA 15W 30W -IN-0821 73718-RAB
rablighting.com Visit our website for product info
Tech Help Line Call our experts: 888 722-1000
e-mail Answered promptly –
sales@rablighting.com
Free Lighting Layouts Answered online or by request
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>