This is a
secure
Wall Controller
for
CEPT (Europe).
Please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
Step 1. Make sure the remote control does not belong to any Z-Wave network,
short press any button, if LED indicator does not turn on, the remote control
does not belong to any network, then continue step 2,if LED indicator turns
on, it means the remote control has already been included to a network, please
first set the remote control to exclusion mode (refer to the part Exclusion”
of this manual),then continue step 2.Step 2. Set primary controller/gateway
into inclusion mode (Please refer to your primary controllers manual on how to
turn your controller into inclusion).Step 3. Press and hold down both buttons
I and O of Group 2 over 3 seconds, LED indicator turns on, the remote control
will be set to inclusion mode, and waiting to be included, after 10s LED
indicator blinks 6 timesquickly to indicate successful inclusion. The remote
control is a sleepy device, after inclusion it will not enter into sleepy mode
immediately, and will continue activation status for 30s and wait data
interaction from the gateway, the LED indicator will stay solid on, please be
patient to wait LED indicator to turn off.
Please refer to the
Manufacturers
Manual for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The remote control is a Z-Wave device that can both control other Z-Wave devices and activate scenes in Gateways. Although it is controlling other devices, the device cannot act as Z-Wave network controller (primary or secondary) and will always need a Z-Wave network controller to be included into a Z-Wave network. It also supports the Over The Air (OTA) feature for the products firmware upgrade.The remote control has following functions:1. Control of groups of other Z-Wave devices using ‘ON’, ‘OFF’ and Dim commands.2. Activation of scenes in Gateway mode.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Press and hold down both buttons I and O of Group 2 for over 10 seconds, LED indicator turns on and then blinks 4 times quickly to indicate successful factory reset.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Step 1. Make sure the remote control does not belong to any Z-Wave network, short press any button, if LED indicator does not turn on, the remote control does not belong to any network, then continue step 2,if LED indicator turns on, it means the remote control has already been included to a network, please first set the remote control to exclusion mode (refer to the part Exclusion” of this manual),then continue step 2.Step 2. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion).Step 3. Press and hold down both buttons I and O of Group 2 over 3 seconds, LED indicator turns on, the remote control will be set to inclusion mode, and waiting to be included, after 10s LED indicator blinks 6 timesquickly to indicate successful inclusion. The remote control is a sleepy device, after inclusion it will not enter into sleepy mode immediately, and will continue activation status for 30s and wait data interaction from the gateway, the LED indicator will stay solid on, please be patient to wait LED indicator to turn off.
Exclusion
There are two exclusion methods:Method 1: Exclusion from the primary controller/gateway as follows:1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion).2. Press and hold down both buttons I and O of Group 2 over 3 seconds, LED indicator turns on, the remote control will be set to exclusion mode, and waiting to be excluded, after 7s LED indicator blinks 4 times quickly to indicate successful exclusion.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 5| 1. Send Command Class u0022Device Reset Locally Notification V1u0022
toassociated devices of this group to report factory reset informationwhen
factory reset the remote control.2. When remote control battery power value
changes, sendCommand Class u0022Battery Report V1u0022 to associated devices
of thisgroup to report power value information.3. Short press or press and
hold down any button to send sceneactivation command to the associated devices
of this group usingCommand Class Central Scene Notification V3
---|---|---
2| 5| Short press I/O button of Group 2 to send ON/OFF command toassociated
devices of this group using Command Class u0022Basic SetV2u0022.Press and hold
down I/O button of Group 2 to send light intensityincrease/decrease command to
associated devices of this groupusing Command Class u0022Multilevel V4u0022.
3| 5| Short press I/O button of Group 3 to send ON/OFFcommand to associated
devices of this group usingCommand Class u0022Basic Set V2u0022.Press and hold
down I/O button of Group 3 to sendlight intensity increase/decrease command
toassociated devices of this group using Command Classu0022Multilevel V4u0022.
4| 5| Short press I/O button of Group 4 to send ON/OFFcommand to associated
devices of this group usingCommand Class u0022Basic Set V2u0022.Press and hold
down I/O button of Group 4 to sendlight intensity increase/decrease command
toassociated devices of this group using Command Classu0022Multilevel V4u0022.
5| 5| Short press I/O button of Group 5 to send ON/OFFcommand to associated
devices of this group usingCommand Class u0022Basic Set V2u0022.Press and hold
down I/O button of Group 5 to sendlight intensity increase/decrease command
toassociated devices of this group using Command Classu0022Multilevel V4u0022.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: factory reset
Value=0x55AA, other values are invalid,factory reset the Remote Control
Size: 2 Byte, Default Value: 0
SettingDescription
21930 | factory reset |
---|
Technical Data
Hardware Platform | ZM5101 |
---|---|
Device Type | Wall Controller |
Network Operation | Portable Slave |
Firmware Version | HW: 1 FW: 1.26 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-19056465 |
Z-Wave Product Id | 0x0330.0x0300.0xa305 |
Z-Wave Scene Type | Central Scene |
Firmware Updatable | Updatable by Consumer by RF |
Security V2 | S2_UNAUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info
- Association V2
- Battery
- Central Scene V3
- Configuration
- Device Reset Locally
- Firmware Update Md V4
- Manufacturer Specific V2
- Multi Channel Association V3
- Powerlevel
- Security
- Security 2
- Supervision
- Transport Service V2
- Version V2
- Wake Up V2
- Zwaveplus Info V2
Controlled Command Classes
- Basic
- Switch Multilevel V4
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)