Kendo S – Installation Instructions Models S –
Please read all instructions prior to installation and keep for future reference!

  1. PRODUCT TO BE INSTALLED BY A QUALIFIED ELECTRICIAN
  2. USE ONIY WITH CLASS 2 POWER UNIT
  3. 24 V0IS DC
  4. SUITABLE FOR DAMP LOCATIONS
  5. SURFACE MOUNT ONIY
  6. SUITABLE FOR INSTALLATION WITHIN THE CLOSET STORAGE SPACE

Fixed mounting clip installation

luminii KS XX Kendo S Dynamic White - Fig1

1.1 Determine the location of where the fixture[s) will be installed. Lay the fixture[s) on the surface and make any necessary reference marks for the fixed mounting clips (or if using the fixed 45° degree mounting clip) Moake marks 4″ from each end of the fixtures] and also every 30″ in between.
1.2lay the fixed clip onto the reference mark points and secure using the provided hardware.

luminii KS XX Kendo S Dynamic White - Fig2

2.1: necessary make any pass through holes for wire lead/connector to the surface, depending on the power feed option. Then snap the fixture into the fixed mounting clip to secure in place. Diagram on the right side illustrates the common way of connecting multiple fixtures to each other, depending on the location of the power teed wires.
Please read all instructions prior to installation and keep for future reference!

  1. PRODUCT TO BE INSTALLED BY A QUALIFIED
  2. USE ONIY WITH CLASS 2 POWER UNIT
  3. 24 V0IS DC
  4. SUITABLE FOR DAMP LOCATIONS
  5. SURFACE MOUNT ONIY ELECTRICIAN
  6. SUITABLE FOR INSTALLATION WITHIN THE CLOSET STORAGE SPAC

Adjustable hinge mounting clip installation

luminii KS XX Kendo S Dynamic White - Fig3

1.1 Determine the location of where the fixture[s) will be installed. lay the fixture[s) on the surface, and make reference marks for the mounting clips. Make marks 4″ from each end of the fixture[s) and also every 30″ in between.
1.2 Slightly loosen the 2 screws on the side on adjustable bracket lay the bracket onto the reference mark points and secure using the provided hardware.

luminii KS XX Kendo S Dynamic White - Fig5

2.1: necessary make any pass through holes for wire lead/connector to the surface, depending on the power feed option. Then snap the fixture into the fixed mounting clip to secure in place. Diagram on the right side illustrates the common way of connecting multiple fixtures to each other, depending on the location of the power teed wires
Please read all instructions prior to installation and keep for future reference!

  1. PRODUCT TO BE INSTALLED BY A QUALIFIED
  2. USE ONIY WITH CLASS 2 POWER UNIT
  3. 24 V0IS DC
  4. SUITABLE FOR DAMP LOCATIONS
  5. SURFACE MOUNT ONIY ELECTRICIAN
  6. SUITABLE FOR INSTALLATION WITHIN THE CLOSET STORAG

Magnetic mounting clip installation

luminii KS XX Kendo S Dynamic White - Fig6

1.1 Determine the location where the fixture[s) will be installed. Must be mode of steel or a ferrous metal Cleon the surface area thoroughly from any debris

luminii KS XX Kendo S Dynamic White - Fig7

2.1 l/ necessary make any pass through holes for wire lead/connector to the surface, depending on the power feed option. Place fixture onto the surface to secure in place. Diagram on the right side illustrates the common way o connecting multiple fixtures to each other, depending on the location of the power teed wires.

Kendo S – Installation Instructions
Models S –
Please read all instructions prior to installation and keep for future reference!

  1. PRODUCT TO BE INSTALLED BY A QUALIFIED
  2. USE ONIY WITH CLASS 2 POWER UNIT
  3. 24 V0IS DC
  4. SUITABLE FOR DAMP LOCATIONS
  5. SURFACE MOUNT ONIY ELECTRICIAN
  6. SUITABLE FOR INSTALLATION WITHIN THE CLOSET STORAGE SPACE

Connect to Power

luminii KS XX Kendo S Dynamic White - Fig8

1.1 Follow one of the two options to connect the fixture to the power supply
Option 1- Secure female quick connect to male quick connect. feed male quick connect wire through conduit to power supply
Option 2- Feed wire whip to the power supply

luminii KS XX Kendo S Dynamic White - Fig9

2.1 Connect +24 VDC red wire from the fixture to the power supply +24 VDC red wire with a wire nut. Connect -24VDC black wire from the fixture to power supply 24VDC black wire with a wire nut.
Kendo S – Installation Instructions
Models S –
Please read all instructions prior to installation and keep for future reference!

  1. PRODUCT TO BE INSTALLED BY A QUALIFIED
  2. USE ONIY WITH CLASS 2 POWER UNIT
  3. 24 V0IS DC
  4. SUITABLE FOR DAMP LOCATIONS
  5. SURFACE MOUNT ONIY ELECTRICIAN
  6. SUITABLE FOR INSTALLATION WITHIN THE CLOSET STORAGE SPACE

Multiple powerfeed layouts

power supplies at the end of the run

luminii KS XX Kendo S Dynamic White - Fig10

power supplies in the middle of the run.

luminii KS XX Kendo S Dynamic White - Fig11

consecutive layout, NOT RECOMMENDED

luminii KS XX Kendo S Dynamic White - Fig12