WATTECO Press’O 0-5V Atex Zone 1 User Guide
- June 9, 2024
- WATTECO
Table of Contents
**WATTECO Press’O 0-5V Atex Zone 1
**
Recommendations for use
The use of accessories:
Installation, maintenance and use must only be carried out by personnel who
are competent in the use of electrical equipment in explosive atmospheres as
defined in EN 60079-14.
Any repair or modification is strictly prohibited without the written
permission of Watteco.
Risk of electrostatic discharge: The user must implement any action to control
the risks of electrostatic discharge, especially by cleaning the product only
with a damp cloth.
USE ONLY SAFT TYPE LS17500 BATTERIES.
Only the use of accessories in accordance with the intrinsic safety parameters
is permitted (see on pages 3-4)
Start
Provision the device on your LoRaWAN® network with the keys available on the
secure platform.
ON :
OFF :
Video :ON – OFF
https://www.watteco.fr/assistance/tutoriels-video/
Connectors
Connector: Red circle: 6 points | |
---|---|
Connector | |
0-5V |
Press’O Atex Zone 1
IP55 : [50-70-151]
IP68 : [50-70-114]
| __
P1: OUT – V+
[~5 , 5Vdc@5mA]
P2: GND
P3: IN-Measure 1
P4: GND
P6: IN-Measure 2
P7: GND
| __
Uo = 6 , 51V
Io = 67mA
Po = 108 mW
Co = 500µF[IIB],
Co = 22µF[IIC]
Lo = 33mH [IIB],
Lo = 8mH [IIC]
The connectivity of the subbase is defined by :
Marking
The 0-5V Press’O sensors are certified according to the harmonised standards EN60079-0 ed. 6 and EN60079-11 ed.6 (EU Type Examination Certificate DEKRA20ATEX0017 X)
Press’O 0-5V
Ex ib IIB, IIC T4 Gb
Ex ib IIIC T135°C Db
-20 ≤ Tamb ≤ +50°C
DEKRA 20ATEX0017 X
WARNING – DO NOT CHANGE THE BATTERY IN EXPLOSIVE ATMOSPHERE – ONLY USE
TYPE OF BATTERY SAFT LS17500 – POTENTIAL
ELECTROSTATIC CHARGING HAZARD – INSTRINSIC SAFETY PARAMETERS FOR CONNECTORS –
SEE INSTRUCTIONS WATTECO – RUE GUTENBERG – 56700
HENNEBONT – FRANCE
Setting up
Opening / Closure
Unscrew the 4 screws by ¼ turn
Wall mounting
Place the dowels and screw the housing to the wall
Radio propagation
Check the radio coverage with the Netw’O.
For the sensor communicates correctly, the number of obstacles should be limited to avoid excessive radio attenuation.
Characteristics
Reference | 50-70-114 | 50-70-151 |
---|---|---|
Class | A | |
Power Level | +14 dBm | |
Measures : | 0-5V | |
Antenna | Internal | |
Casing materials | ASA / PC | |
IP rating | IP55 | IP68 |
SITE SUPPORT
IoT device manufacturer
Thanks for choosing WATTECO devices
Documents / Resources
|
WATTECO Press’O 0-5V Atex Zone
1
[pdf] User Guide
Press O 0-5V Atex Zone 1, Press O, 50-70-114, 50-70-151
---|---
References
- support.watteco.com/
- Concepteur et fabricant de capteurs transmetteurs radio connectés IoT - WATTECO
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>