Product Usage Instructions

Safety Precautions
To prevent injury and property damage, follow these safety precautions:

  • Always use a power plug and socket with a ground terminal.
  • Do not use a defective or underrated circuit breaker; use the correctly rated breaker and fuse.
  • Do not use a multi-consent; always use this appliance on a dedicated circuit and breaker.
  • For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center.
  • Always ground the product as per the wiring diagram.
  • Install the panel and the cover of the control box securely.
  • Do not modify or extend the power cable; replace it if damaged.
  • For installation, removal, or reinstallation, always contact the dealer or an Authorized Service Center.
  • Do not install the product on a defective installation stand.
  • Never install the outdoor unit on a moving base or a place from where it can fall.
  • If the product is soaked in water, contact an Authorized Service Center before use.

Maintenance
Regular maintenance is essential for the proper functioning of your air conditioner. Follow these steps:

  1. Clean or replace filters as recommended in the manual.
  2. Check and clean the indoor and outdoor units periodically.
  3. Ensure proper airflow and ventilation around the unit.
  4. Inspect for any leaks or unusual noises during operation.
  5. Schedule professional maintenance at least once a year.

IMPORTANT

  • Please read this owner’s manual carefully and thoroughly before installing and operating your room air conditioner.
  • Please retain this owner’s manual for future reference after reading it thoroughly.

FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the side of each unit.

Dealer’s Name
Date Purchased

  • Staple your receipt to this page in the event you need it to prove the date of purchase or for warranty issues.

READ THIS MANUAL
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
You’ll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips First, you may not need to call for service at all.

PRECAUTION

  • Contact the authorized service technician for repair or maintenance of this unit.
  • Contact the installer for the installation of this unit. The air conditioner is not intended for use by young children or invalids without supervision. Young children should be supervised to ensure that they do not play with the air conditioner. When the power cord is to be replaced, replacement work shall be performed by authorized personnel only using genuine replacement parts.

Safety Precautions

To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness is classified by the following indications.

WARNING: This symbol indicates the possibility of death or serious injury.
CAUTION: This symbol indicates the possibility of injury or damage.

  • Meanings of symbols used in this manual are as shown below.

CAUTION: Be sure not to do.
WARNING: Be sure to follow the instructions.

WARNING: Always use a power plug and socket with a ground terminal.

  • There is a risk of electric shock.
    For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center. Do not disassemble or repair the product by yourself.

  • There is a risk of fire or electric shock.

Use the correctly rated breaker or fuse.

  • There is a risk of fire or electric shock.

Do not install the product on a defective installation stand. Be sure that the installation area does not deteriorate with age.

  • It may cause the product to fall.

In outdoor units, the step-up capacitor supplies high-voltage electricity to the electrical components. Be sure to discharge the capacitor completely before conducting the repair work.

  • A charged capacitor can cause electrical shock.

Do not use a defective or underrated circuit breaker. Use the correctly rated breaker and fuse.

  • There is a risk of fire or electric shock .

Always ground the product as per the wiring diagram. Do not connect the ground wire to gas or water pipes lightning rod or telephone ground wire.

  • There is a risk of fire or electric shock.

Never install the outdoor unit on a moving base or a place from where it can fall.

  • The falling outdoor unit can cause damage injury or even death of a person.

When installing the unit, use the installation kit provided with the product.

  • Otherwise, the unit may fall and cause severe injury.

Do not use a multi-consent. Always use this appliance on a dedicated circuit and breake r.

  • Otherwise, it can cause electric shock or fire.

Install the panel and the cover of the control box securely.

  • There is a risk of fire or electric shock due to dust, water, etc.

For installation, removal, or reinstall, always contact the dealer or an Authorized Service Center.

  • There is a risk of fire, electric shock, explosion, or injury.

When the product is soaked (flooded or submerged) in water, contact an Authorized Service Center for repair before using it again.

  • There is a risk of fire or electric shock.

Be sure to use only those parts which are listed in the svc parts list. Never attempt to modify the equipment.

  • The use of inappropriate parts can cause an electrical shock, excessive heat generation, or fire.

Indoor/outdoor wiring connections must be secured tightly and the cable should be routed properly so that there is no force pulling the cable from the connection terminals.

  • Improper or loose connections can cause heat generation or fire.

Be sure to check the refrigerant to the used. Please read the label on the product

  • Incorrect refrigerant use can prevent the normal operation of the unit.

Do not place a heater or other heating appliances near the power cable.

  • There is a risk of fire and electric shock.

Do not use the product in a tightly closed space for a long time. Perform ventilation regularly.

  • Oxygen deficiency could occur and hence harm your health.

Ventilate the product room from time to time when operating it together with a stove, heating element, etc.

  • Oxygen deficiency can occur and hence harm your health.

Take care to ensure that nobody especially kids could step on or fall onto the outdoor unit.

  • This could result in personal injury and product damage.

Do not plug or unplug the power supply plug to turn the unit ON/OFF.

  • There is a risk of fire or electric shock.

Safely dispose of the packing materials. Like screws, nails, batteries, broken things, etc after installation or svc, and then tear away and throw away the plastic packaging bags.

  • Children may play with them and cause injury.

Don’t use a power cord, a plug, or a loose socket that is damaged.

  • Otherwise, it may cause a fire or electrical shock.

Do not allow water to run into electric parts. Install the unit away from water sources.

  • There is a risk of fire, failure of the product, or electric shock.

Do not open the front grille of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.)

  • There is a risk of physical injury, electric shock, or product failure.

Turn the main power off and unplug the unit when cleaning or repairing the product.

  • There is a risk of electric shock.

Take care to ensure that the power cable cannot be pulled out or damaged during operation.

  • There is a risk of fire or electric shock.

Make sure to check that the power cable plug is not dirty, loose, or broken, and then only insert the plug completely.

  • A dirty, loose, or broken power plug can cause electric shock or fire.

Do not touch, operate, or repair the product with wet hands. Hold the plug by hand when taking out

  • There is a risk of electric shock or fire

Do not store use or even allow flammable gas or combustibles near the product.

  • There is a risk of fire.

If strange sounds, smell or smoke comes from the product. Immediately turn the breaker off or disconnect the power supply cable.

  • There is a risk of electric shock or fire.

When the product is not to be used for a long time, disconnect the power supply plug or turn off the breaker.

  • There is a risk of product damage failure, or unintended operation.

Do not place ANYTHING on the power cable.

  • There is a risk of fire or electric shock.

When flammable gas leaks, turn off the gas and open a window for ventilation before turning the product on.

  • Do not use the telephone or turn switches on or off. There is a risk of explosion or fire.

CAUTION

Two or more people must lift and transport the product.

  • Avoid personal injury.

Keep level even when installing the product.

  • To avoid vibration or noise.

Do not install the product where it will be exposed to sea wind (salt spray) directly.

  • It may cause corrosion on the product.

Do not install the product where the noise or hot air from the outdoor unit could damage or disturb the neighborhoods.

  • It may cause a problem for your neighbors and hence dispute.

Install the drain hose to ensure that the condensed water is drained away properly.

  • A bad connection may cause water leakage.

Always check for gas (refrigerant) leakage after installation or repair of the product.

  • Low refrigerant levels may cause failure of the product.

Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system.

  • There is a risk of damage or loss of property.

Do not touch the metal parts of the product when removing the air filter.

  • There is a risk of personal injury.

Do not insert hands or other objects through the air inlet or outlet while the product is operating.

  • There are sharp and moving parts that could cause personal injury.

Do not tilt the unit when removing or uninstalling it.

  • The condensed water inside can spill.

Dismantling the unit, treatment of the refrigerant oil and eventual parts should be done by local and national standards.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote if the batteries have leaked.

  • The chemicals in batteries could cause burns or other health hazards.

Do not expose your skin kids or plants to the cool or hot air draft.

  • This could harm your health.

Do not block the inlet or outlet of airflow.

  • It may cause product failure.

Do not step on or put anything on the product. (outdoor units)

  • There is a risk of personal injury and failure of the product.

Be cautious when unpacking and installing the product.

  • Sharp edges could cause injury.

Do not mix air or gas other than the specified refrigerant used in the system.

  • If air enters the refrigerant system, an excessively high-pressure results, causing equipment damage or injury.

Replace the all batteries in the remote control with new ones of the same type. Do not mix old and new batteries or different types of batteries.

  • There is a risk of fire or product failure.

If you eat the liquid from the batteries, brush your teeth and see a doctor. Do not use the remote if the batteries have leaked.

  • The chemicals in batteries could cause burns or other health hazards.

Do not drink the water drained from the product.

  • It is not sanitary and could cause serious health issues.

Use a soft cloth to clean. Do not use harsh detergents, solvents splashing water, etc.

  • There is a risk of fire, electric shock, or damage to the plastic parts of the product.

Always insert the filter securely after cleaning. Clean the filter every two weeks or more often if necessary.

  • A dirty filter reduces the efficiency.

If the refrigerant gas leaks during the repair, do not touch the leaking refrigerant gas.

  • The refrigerant gas can cause frostbite (cold burn)

If the refrigerant gas leaks during the installation, ventilate the area immediately.

  • Otherwise, it can be harmful to your health.

Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire.

  • They may burn or explode.

Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.

  • Moisture may condense and wet or damage furniture.

Use a firm stool or ladder when cleaning, maintaining, or repairing the product at a height.

  • Be careful and avoid personal injury.

Electrical Safety

WARNING

  • This appliance must be properly grounded.
    To minimize the risk of electric shock, you must alway plug into a grounded outlet.

  • Do not cut or remove the grounding prong from the power plug.

  • Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.

  • If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and circuit checked by a qualified electrician.

Temporary of an Adapter

  • We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections, use only a genuine adapter, available from most local hardware stores. Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection.
  • To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage.

WARNING: Never use the appliance with a broken adapter.

Symbols used in this Manual

  • This symbol alerts you to the risk of electric shock.
  • This symbol alerts you to hazards that may cause harm to the air conditioner.
  • This symbol indicates special notes.

Product Introduction

Here is a brief introduction to the indoor and outdoor units. Please see the information specific to your indoor unit type.

Indoor Units

LG-LMAN095HV-Multi-Type-Air-Conditioner-FIG-2

Outdoor Unit

  • The figure can be changed according to the model.

Operating Instructions

How to insert the Batteries

  1. Remove the battery cover by pulling it according to the arrow direction.
  2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly.(Battery Size = AAA)
  3. Reattach the cover by sliding it back into position.

NOTE

  1. Always use/replace both batteries of the same type.
  2. If the system is not to be used for a long time, remove the batteries to save their working life.
  3. If the display screen of the remote controller starts, fading replace both of the batteries.

Wireless Remote Controller Maintenance

  1. Choose a suitable place where it’s safe & easy to reach.
  2. Fix the holder to the wall etc with the supplied screws firmly.
  3. Slide the remote controller inside the holder.

NOTE

  1. Remote controllers should never be exposed to direct sunlight.
  2. The signal transmitter & receiver should always be clean for proper communication. Use a soft cloth to clean them.
  3. In case some other appliances also get operated with remote control, change their position or consult your serviceman.

Operation Indication Lamps

[Standard/Artcool Mirror Type]

LG-LMAN095HV-Multi-Type-Air-Conditioner-FIG-6

  • Hot start operation: Stops the indoor fan in the heating operation for minutes to prevent cold air from blowing out from the unit.
  • In defrost mode unit stops heating operation for a few minutes to remove the formation of ice on the heat exchanger coils to maintain the efficiency.

[Ceiling Cassette Type]

LG-LMAN095HV-Multi-Type-Air-Conditioner-FIG-8

Operating Method

  1. The signal receiver is inside the unit.
  2. Aim the remote controller towards the unit to operate it. There should not be any blockage in between.

LG-LMAN095HV-Multi-Type-Air-Conditioner-FIG-9

Wireless Remote  Controller

  1. PLASMA Button (Optional)
    Used to start or stop the plasma-purification function.

  2. JET COOL Button
    Speed cooling operates super high fan speed.

  3. OPERATION MODE SELECTION Button
    Used to select the operation mode.

  4. FUNCTION SETTING Button
    Used to set or clear Auto Clean or Amart Clean.

  5. LCD LUMINOSITY Button (Optional)
    Used to adjust LCD luminosity

  6. SMART CLEAN Button (Optional)
    Used to start or stop Smart Clean.

  7. CLEAR ALL Button
    Used to clear all timers.

  8. ROOM TEMPERATURE SETTING Button
    Used to select the room temperature.

  9. ON/OFF Button
    Used to turn on/off the unit.

  10. INDOOR FAN SPEED SELECTION Button
    Used to select fan speed in four steps low, medium, high, and chaos.

  11. UP/DOWN AIRFLOW Button
    Used to stop or start louver movement and set the desired up/down airflow direction.

  12. LEFT/RIGHT AIRFLOW Button(Optional)
    Used to set the desired left/right(horizontal) airflow direction.

  13. TIMER AND TIME SETTING Button
    Used to set the time of starting or stopping and sleeping operation.

  14. ROOM TEMPERATURE CHECKING Button
    Used to check the room temperature.

  15. °C/°F SWITCH Button
    Used to switch temperature readings from Celsius to Fahrenheit.

  16. RESET Button
    Used to reset the remote controller.

LG-LMAN095HV-Multi-Type-Air-Conditioner-FIG-10

NOTE: Some functions may not be operated and displayed depending on the product type.

Wired Remote Controller (Optional)

  1. OPERATION INDICATION SCREEN

  2. SET TEMPERATURE Button

  3. WIRELESS REMOTE CONTROLLER RECEIVER
    Some products don’t receive wireless signals.

  4. VENTILATION Button

  5. OPERATION MODE SELECTION Button

  6. SUBFUNCTION Button

  7. FUNCTION SETTING Button

  8. EXIT Button

  9. ON/ OFF Button

  10. ROOM TEMPERATURE Button FAN SPEED Button

  11. AIR FLOW Button

  12. RESERVATION/ TIME SETTING Button

  13. SETTING/ CANCEL Button

  14. UP, DOWN, LEFT, RIGHT Button

  15. RESET Button

NOTE

  • Display temperature can be different from actual room temperature if the remote controller is installed at a place where sunrays are falling directly or the place near a heat source.
  • The actual product can be different from the above contents depending upon the model type.

Operation Mode

  1. Press the ON/OFF BUTTON to turn the unit on.

  2. The unit will respond with a beep.
    Open the door of the remote controller and press the operation mode button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.LG-LMAN095HV-Multi-Type-Air-Conditioner-
FIG-14

  3. For cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS.

    • For cooling the temperature can be set within
    • 18°C~30°C(64°F~86°F) and for heating the temperature range is
    • 16°C~30°C(60°F~86°F).
  4. Set the fan speed with the remote controller. You can select the fan speed in four steps, medium, high, and CHAOS by pressing the INDOOR FAN SPEED SELECTOR BUTTON.
    Each time the button is pressed, the fan speed mode is shiftedLG-LMAN095HV-
Multi-Type-Air-Conditioner-FIG-16

Natural wind by the CHAOS logic

  • For a fresher feeling, press the INDOOR FAN SPEED SELECTOR BUTTON selector and set it to CHAOS mode.
  • In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic

Helpful information

  • Fan speed and cooling capacity.
  • The cooling/heating capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed.
  • High fan speed is recommended when you wish to cool/heat the room quickly.

LG-LMAN095HV-Multi-Type-Air-Conditioner-FIG-17

Healthy Dehumidification  Operation

During Healthy Dehumidification Operation

  • If you select the dehumidification mode on the OPERATION MODE SELECTION BUTTON, the product starts to run the dehumidification function. It automatically sets the room temperature and airflow volume to the best condition for dehumidification, based on the sensed current room temperature.
    In this case, however, the setting temperature is not displayed on the remote controller and you are not able to control the room temperature either.

  • During the healthy dehumidification function, the airflow volume is automatically set according to the optimization algorithm responding to the current room temperature status, so that the room condition is kept healthy and comfortable even in the very humid season.

Air Circulation Operation

This operation circulates the air without cooling or heating. It can be activated by pressing the OPERATION MODE SELECTION BUTTON. Once the air circulation is activated you can select the air speed by pressing the INDOOR FAN SPEED SELECTOR BUTTON.

NOTE: CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically changed from high to low or vice versa, depending on the ambient temperature.

Auto Operation

In this operation mode, the system is automatically operated by the electronic controls.
You can set the desired temperature between 64°F and 86°F for Auto Operation mode.

NOTE

  • You can set the fan speed in this operation mode only from the installed wired remote controller.
  • This function properly operates when you use the remote controller to match each model.

Jet Cool Operation

Jet cool function can be used to cool the room quickly in hot summer. When this function is turned on, the air conditioner runs in cooling operation mode with super high fan speed and 18°C setting temperature for 30 minutes for fast and effective cooling.

Plasma purification can be started by pressing the PLASMA BUTTON on the remote controller. Repressing it will deactivate the operation.

NOTE: This feature can be used in any operation mode and any fan speed can be used while the plasma filter is functioning.

Auto Clean(Optional)
During auto clean function, moisture left in indoor units after cooling operation or healthy dehumidification operation can be removed.

This function operates when the unit is turned off.

  1. Press the FUNCTION SETTING button 1 time. Auto Clean symbol will blink.
  2. Press the SET/CLEAR button to reserve or cancel the Auto Clean function.
  3. If the Auto Clean function is reserved, whenever the unit is turned off, the indoor fan is still running for about 30 minutes internally without cooling or dehumidification operation. Also, the louver is closed.
    This dries up any remains of moisture & cleans the unit internally.

Display Luminosity (Artcool Mirror Type Only)

  • The Display Luminosity can be adjusted by using the remote control.
  • Open the door of the remote controller, and press the LCD LUMINOSITY button.
  • The display will be dark. Press the button again to set a bright display.

CAUTION: Because Display Luminosity is an optional function, some products will not operate.

Forced operation

  • Operation procedures when the remote control can’t be used.
  • The operation will be started if the ON/OFF button is pressed.
  • If you want to stop the operation, re-press the button.

LG-LMAN095HV-Multi-Type-Air-Conditioner-FIG-31

 | Room Temp. ³ 24°C(75.2°F)| 21°C(69.8°F) £ Room Temp. < 24°C(75.2°F)| Room Temp. < 21°C(69.8°F)
---|---|---|---
Operating mode| Cooling| Healthy Dehumidification| Heating
Indoor FAN Speed| High| High| High
Setting Temperature| 22°C(72°F)| 23°C(74°F)| 24°C(76°F)

Test operation

  • During the TEST OPERATION, the unit operates in cooling mode at the high-speed fan, regardless of room temperature, and resets in 18 minutes.
  • During test operation, if a remote controller signal is received, the unit operates as remote controller sets.
  • If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sounds 1 “beep”.
  • If you want to stop the operation, re-press the button.

Setting the Current Time

  1. Press the TIMER button for 3 seconds.
  2. Press the TIME SETTING buttons until the desired time is set. NOTE: Check the indicator for A.M. and P.M.
  3. Press the SET / CLEAR button.

Timer Setting

  1. Press the TIMER button to turn the timer on or off.

  2. Press the TIME SETTING buttons until the desired time is set.
    NOTE Select one of the following 3 types of operation.LG-LMAN095HV-
Multi-Type-Air-Conditioner-FIG-36

  3. Press the SET / CLEAR button

To cancel the Timer Setting

  • If you wish to cancel all timer settings, press the CLEAR ALL button.
  • If you wish to cancel each timer setting, press the
    TIMER button to turn the timer sleep or on or off as you want.
    Then press the SET/CLEAR button aiming the remote controller at the signal receptor.
    (The timer lamp on the air conditioner and the display will go off.)

Up/Down Airflow  Direction  Control

The up/down airflow (Vertical Airflow) can be adjusted by using the remote controller.

  1. Press the ON/OFF button to start the unit.
  2. Press the UP/DOWN AIRFLOW button and the louvers will swing up and down.
    Press the UP/DOWN AIRFLOW button again to set the vertical louver at the desired airflow direction.

NOTICE

  • If you press the UP/DOWN AIRFLOW button, the horizontal airflow direction is changed automatically based on the Auto Swing algorithm to distribute the air in the room evenly and at the same time to make the human body feel more comfortable, as if enjoying a natural breeze.
  • Always use the remote controller to adjust the up/down airflow direction. Manually moving the vertical airflow direction louver by hand, could damage the air conditioner.
  • When the unit is shut off, the up/down airflow direction louver will close the air outlet vent of the system.

Left/Right Airflow Direction Control (Optional)

The left/right(horizontal) airflow can be adjusted by using the remote control.

  1. Press the ON/OFF button to start the unit.
  2. Press the LEFT/RIGHT AIRFLOW button and the louvers will swing left and right. Press the Horizontal Airflow Direction Control Button again to set the horizontal louver at the desired airflow direct I o n. The up/Down and Left/Right Airflow function isn’t shown on the display of the remote controller.

Auto Restart Function

  • This function is useful in the situation of power failure.
  • When power regains after a failure this feature restores the previous operating condition and the air conditioner will run in the same settings.

NOTE

  • This feature is enabled by the factory default setting, but you can disable it by pressing the ON/OFF button for 6 seconds. The unit will beep twice and the indicator lamp will blink 4 times.
  • To enable it, press the button again for 6 seconds.
  • The unit will beep twice and the indicator lamp will blink 4 times.

Maintenance and Service

CAUTION: Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker, and unplug the power cord.

Standard/Artcool Mirror Type
Clean the unit with a soft dry cloth. Do not use bleach or abrasives.

CAUTION: Never use any of these

  • Water hotter than 40°C(104°F). It may cause deformation and discoloration.
  • Volatile substances. They may damage the surface of the air conditioner.

Air Filters
The air filters behind the front panel/grill should be checked and cleaned once every 2 weeks or more often if necessary. To remove the filters see the self-explanatory diagrams for each model type. Clean the filters with a vacuum cleaner or warm soapy water. If dirt is not easily removed, wash with a solution of detergent in lukewarm water. Dry well in the shade after washing and reinstall the filters back in place.

Plasma Filters
The plasma filters behind the air filter should be checked and cleaned once every 3 months or more often if necessary. To remove the filters see the self- explanatory diagrams for each model type. Clean the filters with a vacuum cleaner. If it is dirty wash it with water dry the well in the shade an install it back in place.

Deodorizer Filters

  • Remove the deodorizer filters behind the air filter and expose them to direct sunlight for 2 hours.
  • And then insert these filters into the original position.LG-LMAN095HV-Multi-Type-Air-Conditioner-FIG-41

Removal of Filters

  • Open the front panel as shown.
  • Then pull the filter tab slightly forward to remove the air filter.
  • After removing the air filter remove the plasma and deodorizer filter by slightly pulling forward.

[Artcool Mirror Type]

LG-LMAN095HV-Multi-Type-Air-Conditioner-FIG-42

[Standard Type]

LG-LMAN095HV-Multi-Type-Air-Conditioner-FIG-43

WARNING: Don’t touch this plasma filter within 10 seconds after opening the inlet grille, it may cause an electric shock.

How to use the front panel [Artcool Mirror Type]

Front panel closing
Move the link upward and close the front panel.

Front panel removing
Raise the link to the hook hanger and remove the front panel forward.

Ceiling Cassette  Type

Grille, Case, and Remote Control
Turn the system off before cleaning, To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.

NOTE: Supply power must be disconnected before cleaning the indoor unit.

Air Filters
The air filters behind the front grille should be checked and cleaned once every 2 weeks or more often if neccessary.

Never use any of the following:

  • Water hotter than 40°C.
    Could cause deformation and/or discoloration.

  • Volatile substances.
    Could damage the surfaces of the air conditioner.

  1. Remove the Air filters.
    Take hold of the tab and pull slightly forward to remove the filter.
    CAUTION: When the air filter is to be removed, do not touch the metal parts of the indoor unit. It may cause an injury.

  2. Clean dirt from the air filter using a vacuum cleaner or washing with water.

  3. If dirt is conspicuous, wash with a neutral detergent in lukewarm water.

  4. If hot water (50°C or more) is used, it may be deformed.

  5. After washing with water, dry well in the shade.

    • Do not expose the air filter to direct sunlight or heat from a fire when drying it.
  6. Install the air filter.

Operation Tips

Do not overcook the room.

  • This is not good for the health and wastes electricity.

Make sure that the doors and windows are shut tight.

  • Avoid opening doors and windows as much as possible to keep the cool air in the room.

Keep blinds or curtains closed.

  • Do not let direct sunshine enter the room when the air conditioner is in operation.

Clean the air filter regularly.

  • Blockages in the air filter reduce the airflow and lower cooling and dehumidifying effects. Clean at least once every two weeks.

Keep the room temperature uniform.

  • Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room.

Ventilate the room occasionally.

  • Since windows are kept closed, it is a good idea to open them and ventilate the room now and then.

Use high fan speed for effective and fast cooling.

  • The unit gives its rated cooling capacity when the fan speed is high.

FAQs

  • Q: Where can I find replacement parts for LG LMAN095HV?
    • A: Genuine replacement parts for LG LMAN095HV can be found on the Appliance Factory Parts website.
  • Q: What should I do if my air conditioner stops working?
    • A: Refer to the troubleshooting tips in the manual first. If the issue persists, contact an Authorized Service Center for assistance.
  • Q: How often should I clean the filters?
    • A: The filters should be cleaned or replaced according to the manual, typically every few months depending on usage.