General Description
The Orion-Tr Smart DC-DC Charger can be used as a power supply or as a battery
charger. In charger mode the three-state charge algorithm will increase
battery life by properly charging the battery. Especially in the case of
vehicles with a smart alternator, or voltage drop caused by long cable runs,
controlled charging is indispensable. Controlled charging will also protect
the alternator in lithium systems where direct charging can overload the
alternator due to the low impedance of the lithium battery. In fixed output
mode the output voltage will remain stable independent of the applied load or
varying input voltage (within the specified range).
The Orion-Tr Smart DC-DC Charger can be set up to only provide power when the
engine is running. This is possible thanks to the built-in engine shutdown
detection. This also prevents the onboard voltage of the vehicle from becoming
too low. It is not necessary to intervene in the system of the vehicle, to
install a separate motor run sensor or to intervene in the CAN-bus system.
Apart from this detection, the Orion-Tr Smart DC-DC Charger Isolated can also
be activated by a forced allowed to charge feature, e.g. connected to the
ignition switch.
The Orion-Tr Smart DC-DC Charger is fully programmable with the VictronConnect
App. Discover all setup possibilities in the VictronConnect manual.
Features
Smart alternator compatibility
Vehicle manufacturers are now introducing smart ECU (Engine Control Unit)
controlled alternators to increase fuel efficiency and reduce emissions. Smart
alternators deliver a variable output voltage and are shut down when they’re
not needed. The converter has an engine running detection mechanism. This
prevents the converter from discharging the starter battery when the
alternator does not supply power. See section 5 of this manual for more
details.
Separation of the starter battery and the service battery
The Orion-Tr Smart DC-DC Charger Isolated separates the starter battery from
the service battery when the engine is not running.
Extensive electronic protection
Over-temperature protection and power derating when temperature is high.
- Overload protected.
- Short circuit protected.
- Connector over-temperature protection.
Adaptive three step charging
The Orion-Tr Smart DC-DC Charger Isolated is configured for a three-step
charging process:
Bulk – Absorption – Float.
Bulk
During this stage the controller delivers as much charge current as possible
to rapidly recharge the batteries.
Absorption
When the battery voltage reaches the absorption voltage setting, the
controller switches to constant voltage mode. For lead acid batteries it is
important that during shallow discharges the absorption time is kept short in
order to prevent overcharging of the battery. After a deep discharge the
absorption time is automatically increased to make sure that the battery is
completely recharged. For lithium batteries absorption time is fixed, default
2 hours. The fixed or adaptive mode can be chosen on the battery settings.
Float
During this stage, float voltage is applied to the battery to maintain it in a
fully charged state. When the battery voltage drops substantially below this
level, due to a high load for example, during at least 1 minute, a new charge
cycle will be triggered.
Flexible charge algorithm
Programmable charge algorithm, and eight preprogrammed battery settings.
Configurable with VictronConnect.
Adaptive absorption time
Automatically calculates the proper absorption time. Configurable with
VictronConnect.
Configuring and monitoring
Bluetooth Smart built-in: the wireless solution to set-up, monitor and update
the controller using Apple and Android smartphones, tablets or other devices.
Several parameters can be customized with the VictronConnect App.
The VictronConnect App can be downloaded from: https://www.victronenergy.com /support-and-downloads/software
Use the VictronConnect manual – to get the most out of the VictronConnect App when it’s connected to an Orion Smart.
Input voltage lock-out
Shutdown if the input voltage drops below the lock-out value and restart when
the input voltage increases above the restart value. Configurable with
VictronConnect.
Remote on-off
Use the remote function to enable and disable the converter remotely with the
remote on/off connector or using the VictronConnect App. Typical use cases
include a user-operated hard-wired switch and automatic control by for example
a Battery Management System.
Safety instructions
SAVE THESE INSTRUCTIONS – This manual contains important instructions that shall be followed during installation and maintenance.
Danger of explosion from sparking Danger of electric shock
- Please read this manual carefully before the product is installed and put into use
- Install the product in a heatproof environment. Ensure therefore that there are no chemicals, plastic parts, curtains or other textiles, etc. in the immediate vicinity of the equipment.
- It is normal for the Orion Smart DC-DC charger to get hot during operation, keep any objects that are heat-sensitive away
- Ensure that the equipment is used under the correct operating conditions. Never operate it in a wet environment.
- Never use the product at sites where gas or dust explosions could occur
- Always provide proper ventilation during charging
- Avoid covering the charger
- Refer to the specifications provided by the manufacturer of the battery to ensure that the battery is suitable for use with this product. The battery manufacturer’s safety instructions should always be observed
- In addition to this manual, the system operation or service manual must include a battery maintenance manual applicable to the type of batteries used.
- Never place the charger on top of the battery when charging
- Prevent sparks close to the battery. A battery being charged could emit explosive gasses
- This device is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction.
- Use flexible multistranded copper cable for the connections. The maximum diameter of the individual strands is 0,4mm/ 0,125mm² (0.016 inch/AWG26).
- The installation must include a fuse in accordance with the recommendations in the table ”CABLE AND FUSE RECOMMENDATIONS”
Installation
General
- Mount vertically on a non-flammable surface, with the power terminals facing downwards. Observe a minimum clearance of 10 cm under and above the product for optimal cooling.
- Mount close to the battery, but never directly above the battery (in order to prevent damage due to gassing of the battery).
Connection setup for DC-DC converter mode
- Disconnect the remote on/off (remove wire bridge).
- Connect the input supply cables.
- Open the VictronConnect App to setup the product. (always adjust the output voltage before connecting in parallel or connecting a battery)
- Connect the load. The converter is now ready for use.
- Reconnect the remote on/off to activate the product.
Figure 1: Typical connection setup as DC-DC converter
Connection setup for charger mode
- Disconnect the remote on/off (remove wire bridge).
- Connect the input supply cables.
- Open the VictronConnect App to setup the product. (always setup the correct charger algorithm before connecting a battery)
- Connect the battery to be charged.
- Reconnect the remote on/off to activate the product.
Figure 2: Typical connection setup as charger
Connection remote on-off
The recommended use of the remote on-off is:
- a) A switch wired between the L-H pins (On-level impedance between L-H pins: < 500kΩ)
- b) A switch wired between (input/starter) battery plus and H-pin (on level: > 3V)
- c) A switch between the L-pin and (input/starter) ground (on level: < 5V)
- d) Isolated remote on-off cable e.g. controlled by a (small)BMS
Voltage tolerance L & H pin: +/- 70VDC
Engine shutdown detection override
In charger mode the “engine shutdown detection sequence” determines if
conditions are met to enable charging, see chapter 5. The “engine shutdown
detection override” forces the charger to allow charging independently of the
engine shutdown detection. Engine shutdown detection override is activated by
applying >7V to the remote L-pin. This allows external control (e.g. ignition
switch, CAN bus engine on detector) to enable charging.
This function does not override the remote on-off function. Remote connection a), b) or d), as shown in Figure 3 must be configured in combination with engine shutdown detection override. See examples in figure 4.
Enable charging with an ignition switch and remote on-off option a)
Figure 4: Engine shutdown detection override connection diagram
If the ignition switch in figure 4 is switched off, the charger will return to “engine shutdown detection” mode, it will not turn off the charger.
To force enable/disable charging (i.e turn the ORION on/off) without the “engine shutdown detection” a remote option as given in chapter 4.4 must be wired, and the engine shutdown detection must be switched off in VictronConnect, see figure 5.
Figure 5: Disable engine shutdown detection
When the engine shutdown detection has been switched off in Victron Connect (‘forced charging’) current will be drawn from the starter battery even if the engine is not running.
During ‘forced charging’ the input voltage lockout is the only limit left to disable charging automatically, make sure this level is not set too low, in most applications 12.5V is sufficiently low.
Cable and fuse recommendations
| Minimum cable gauge
---|---
Voltage rating (Input or output)| External battery protection Fuse| 0.5m| 1m|
2m| 5m| 10m
12 V| 60 A| 6mm2| 10mm2| 10mm2| 16mm2| 16mm2
24 V| 30 A| 4mm2| 6mm2| 6mm2| 10mm2| 10mm2
Recommended torque
Torque: 1.6Nm
Figure 7: Tightening torques
Engine shuthown detection
The engine shutdown detection mechanism simplifies your ORION-Tr DC-DC Charger
system by detecting if the engine is running without wiring additional
switches or sensors. The factory default setting will work with most regular
and smart alternators but can be re-configured with the VictronConnect App.
Configuring the engine shutdown detection depends on the voltage generated by
the alternator when the engine is running. Regular alternators will generate a
fixed voltage (e.g. 14V) where smart alternators generate a variable output
voltage which can range from 12.5V to 15V. Especially smart alternators in a
regenerative braking system show large alternator voltage variations.
Engine shutdown detection is only active in charger mode. The feature can be
disabled by the “engine shutdown detection override” and in VictronConnect as
shown in figure 5. In power supply mode the “input voltage lock-out”
determines when the output is active.
The engine shutdown detection is updated from software version v1.05 onwards.
Engine shutdown detection sequence
Figure 8: Engine shutdown detection sequence
0 → 1: If the engine runs the alternator voltage will ramp-up, when Vstarter >
Vstart, charging is enabled.
1 → 2: The input current produces a voltage across the input cable (Vcable);
this voltage reduces the voltage measured by the charger (VIN). If VIN >
Vshutdown the charger will operate at Imax.
2 → 3: If VIN ≤ Vshutdown, the charge current will be reduced to prevent VIN
to drop below Vshutdown.
3 → 4: If VIN < Vshutdown for longer than 1min (tshutdown) “engine off” is
detected and charging is disabled. If VIN > Vshutdown before tshutdown runs
out, charging remains enabled.
4 → 5: If Vstart(delay) < VIN < Vstart charging is enabled after tstart delay
(configurable).
Engine shutdown detection setup with VictronConnect
Open VictronConnect and press the Cog symbol to enter the settings.
Figure 9: Engine shutdown detection setup menu
The following settings can be changed with VictronConnect:
The default values displayed are for the 12V input models. Those values are scaled depending on the input voltage of the model. E.g. for 24V input models, the default values displayed on the manual should be multiplied by 2.
Engine shutdown detection enabled: The engine shutdown detection is
always enabled by default when the charger mode is selected. When it is
disabled by the user or when power supply mode is selected, the engine is
considered to be running, so no shutdown detection will take place.
Alternator type: The alternator type can be selected between “Smart
Alternator”, “Regular Alternator” and “User defined”. When “Smart Alternator”
option is selected, the default values for the smart alternator are/will be
applied to the engine shutdown detection settings. The same will happen when
“Regular Alternator” option is selected. When any of the settings differs from
the default values of the last two option, the “User defined” option will be
selected. Default: “Smart Alternator”.
Start voltage (Vstart): At this level charging starts immediately.
Default: 14V.
Delayed start voltage (Vstart(delay)): Smart alternators can generate a
lower voltage when the engine is running, therefore a lower start level is
necessary for these systems. To ensure that the starter battery is recharged
after starting the engine, charging of the auxiliary battery is delayed during
this condition. The energy used during starting must be replenished to ensure
that the starter battery remains properly charged. Default: 13.3V (Smart
Alternator) and 13.8 (Regular Alternator).
Delayed start voltage delay (tstart delay): Recharge time for the starter
battery during start level (delayed). Example: If the starter draws 150A for
5sec to start the engine, about ~0.2Ah is drawn from the starter battery. If,
during engine idling, the alternator can only generate 20A, it takes 150A/20A
x 5sec =37.5sec to recharge the starter battery. Default: 2 minutes.
Shutdown voltage (Vshutdown): This level corresponds with the engine
being off. This keeps the starter battery fully charged and provides a
hysteresis with respect to the start level. The hysteresis must be large
enough to prevent VIN to drop to Vshutdown which would result in charge
current reduction. Action will be taken after tshutdown runs out (1 minute);
this allows charging during temporary low voltage conditions. Default: 13.1V
(Smart Alternator) and 13.5V (Regular Alternator).
Range for engine start/shutdown levels:
- 12|12; 12|24: 8 to 17V
- 24|12; 24|24: 16 to 35V
Setup input voltage lock-out: Input voltage lock-out is the minimum level at which charging is allowed, below this level charging stops immediately. Default (in charger mode): lock-out: 12.5V / restart: 12.8V. Default (in power supply mode): lock-out: 10.5V /restart: 12V.
When ‘forced charging’ is enabled, current will be drawn from the starter battery if the engine is not running. Setting the lock-out level very low can result in a depleted starter battery.
To setup input voltage lock-out two criteria are important:
- Minimum alternator voltage: A smart alternator can operate at very low alternator voltage (<12.5V) e.g. when the vehicle accelerates. This low voltage is allowed during tshutdown as shown in “engine shutdown detection sequence 3→4”. If charging must remain enabled during this period, the lock-out level must at least be set below the minimum alternator voltage.
If the low voltage period exceeds tshutdown charging will be disabled on engine shutdown detection.
- Voltage drop across the input cable: As seen in “engine shutdown detection sequence 1→3”, VIN will be lowered by Vcable. When the alternator voltage drops fast (smart alternator) the charge-control needs some time to reduce charge current and keep VIN at Vshutdown. During this time Vcable must not trip the voltage lock-out. Therefore, the lock-out value should be: Vlock-out ≤ Vshutdown – Vcable.
Example: Calculate the input cable voltage drop:
- Distance between starter battery and charger: 5m.
- Vshutdown= 13.1V. Recommended wire gauge: 16mm2.
- Cable resistance: ~1.1mΩ/m @20°C, thus Rcable = 1.1mΩ x 10m (2x 5m) = 11mΩ.
- A 12|12-30A Smart Charger will draw about 35A from the input when running at full capacity, resulting in:
- Vcable = 11mΩ x 35A = 385mV.
- Vlock-out ≤ Vshutdown – Vcable = 13.3V – 385mV ≈ 12.9V.
Cable connections, external fuses, temperature, etc. influences the total cable resistance.
LED’s
The LEDs will change its state to warn what the Orion Smart is doing at the moment. There are two LEDs, the blue LED is dedicated to Bluetooth functionality and the green LED to product state.
Status LED (Green LED)
-
LED off:
-
No input voltage
-
Remote shutdown;
-
Shutdown by the user;
-
Connector over-temperature protection
-
User defined under voltage lock-out
-
Engine off detected (when in Charger mode)
-
LED on:
-
Output active on Power supply mode
-
Charger in Float State (Battery charged);
-
LED Blinking at 1.25Hz:
-
Charger in Bulk or Absorption State (Battery is being charged);
BLE LED (Blue LED) -
LED off:
- No input voltage;
-
LED Blinking at 0.33 Hz:
- Error – needs to be checked on VictronConnect;
-
LED Blinking at 1.25 Hz
- Connected via Bluetooth
-
LED Blinking at 2.5 Hz:
- Identify;
-
LED Blinking once every 5 seconds:
- Charger off due to non-error conditions as:
- Remote shutdown;
- Shutdown by the user;
- User defined under voltage lock-out;
- Engine off detected (when in Charger mode);
-
LED on
- All other conditions
Specifications
Orion-Tr Smart DC-DC Charger Isolated 220-280 Watt| 12/12-18 (220W)|
12/24-10 (240W)| 24/12-20 (240W)| 24/24-12 (280W)
---|---|---|---|---
Input voltage range (1)| 8-17 V| 8-17 V| 16-35V| 16-35V
Under voltage shut down| 7 V| 7 V| 14V| 14V
Under voltage restart| 7.5 V| 7.5 V| 15V| 15V
Nominal output voltage| 12.2 V| 24.2 V| 12.2V| 24.2V
Output voltage adjust range| 10-15 V| 20-30 V| 10-15V| 20-30V
Output voltage tolerance| +/- 0.2 V
Output noise| 2 mV rms
Cont. output current at nominal output voltage and 40°C| 18 A| 10 A| 20 A| 12
A
Maximum output current (10 s) at nominal output voltage| 25 A| 15 A| 25 A| 15
A
Short circuit output current| 40 A| 25 A| 50 A| 30 A
Cont. output power at 25° C| 280 W| 280 W| 300 W| 320 W
Cont. output power at 40° C| 220 W| 240 W| 240 W| 280 W
Efficiency| 87%| 88%| 88%| 89%
No load input current| < 80 mA| < 100 mA| < 100 mA| < 80 mA
Standby current| Less than 1mA
Galvanic| 200V dc between input, output and case
Operating temperature range| -20 to +55°C (derate 3% per °C above 40°C)
Humidity| Max. 95% non-condensing
DC connection| Screw terminals
Maximum cable cross-section| 16mm² AWG6
Weight| 1.3 kg (3 lb)
Dimensions h x w x d| 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)
Standards: Safety Emission Immunity
Automotive Directive
| EN 60950
EN 61000-6-3, EN 55014-1
EN 61000-6-2, EN 61000-6-1, EN 55014-2 ECE R10-5
Table 1. Specifications
Orion-Tr Smart DC-DC Charger Isolated 360 – 400 Watt| 12/12-30 (360
W)
| 12/24-15 (360
W)
| 24/12-30 (360W)| 24/24-17 (400W)
---|---|---|---|---
Input voltage range (1)| 10-17 V| 10-17 V| 20-35 V| 20-35 V
Under voltage shut down| 7 V| 7 V| 14 V| 14 V
Under voltage restart| 7.5 V| 7.5 V| 15 V| 15 V
Nominal output voltage| 12.2 V| 24.2 V| 12.2 V| 24.2 V
Output voltage adjust range| 10-15 V| 20-30 V| 10-15 V| 20-30 V
Output voltage tolerance| +/- 0.2mV
Output noise| 2 mV rms
Cont. output current at nominal output voltage and 40°C| 30 A| 15 A| 30 A| 17
A
Orion-Tr Smart DC-DC Charger Isolated 360 – 400 Watt| 12/12-30 (360
W)
| 12/24-15 (360
W)
| 24/12-30 (360W)| 24/24-17 (400W)
---|---|---|---|---
Maximum output current (10 s) at nominal output voltage| 40 A| 25 A| 45 A| 25
A
Short circuit output current| 60 A| 40 A| 60 A| 40 A
Cont. output power at 25°C| 430 W| 430 W| 430 W| 480 W
Cont. output power at 40°C| 360 W| 360 W| 360 W| 400 W
Efficiency| 87%| 88%| 88%| 89%
No load input current| < 80 mA| < 100 mA| < 100mA| < 80mA
Standby current| Less than 1 mA
Galvanic isolation| 200 V dc between input, output and case
Operating temperature range| -20 to +55° C (derate 3% per °C above 40° C)
Humidity| Max. 95% non-condensing
DC connection| Screw terminals
Maximum cable cross-section| 16 mm² AWG6
Weight| 12 V input and/or 12 V output models: 1.8 kg (3 lb)
Other models: 1.6 kg (3.5 lb)
Dimensions hxwxd| 12 V input and/or 12 V output models: 130 x 186 x 80 mm (5.1 x 7.3 x
3.2 inch)
Other models: 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)
Standards: Safety Emission Immunity
Automotive Directive
| EN 60950
EN 61000-6-3, EN 55014-1
EN 61000-6-2, EN 61000-6-1, EN 55014-2 ECE R10-5
- If set to nominal or lower than nominal, the output voltage will remain stable within the specified input voltage range (buck-boost function). If the output voltage is set higher than nominal by a certain percentage, the minimum input voltage at which the output voltage remains stable (does not decrease) increases by the same percentage.
Note 1) The VictronConnect App will not display current in or current out.
Note 2) The Orion-Tr Smart DC-DC Charger Isolated is not equipped with a VE.Direct port.
VictronConnect – Orion Smart DC-DC Charger
Introduction
Thank you for using VictronConnect. This guide will help you get the most out
of your Orion Smart DC-DC Charger and it requires a minimum knowledge of this
charger that can be found in the introduction. The information available here
applies to all Orion Smart DC-DC Chargers. To simplify the reference to the
Orion Smart DC-DC Charger, it will be refer as just Orion Smart in this guide.
More general information about the VictonConnect App – how to install it; how
to pair it with your device; and how to update firmware, for example – can be
found by referring to the overall VictronConnect manual.
Note: Where input and battery voltage is referred to in these instructions, a
12V input and battery is assumed. Please multiply the given values by 2 to
arrive at settings for an installation configured for 24V.
Live Data Information
Charger Mode – STATUS tab
-
Orion Smart [SERIAL NUMBER] confirms the connected device. A custom name can also be set if desired.
-
Mode icon shows in which mode the Orion Smart is operating (Charger in this case)
Charger State:- Bulk: During this stage the Orion Smart delivers as much charge current as possible to rapidly charge the batteries. When the battery voltage reaches the Absorption voltage setting, the Orion Smart activates the Absorption stage.
- Absorption: During this stage the Orion Smart switches to the constant voltage mode, where a pre-set absorption voltage, suitable to the battery type (See Settings below), is applied. When the Absorption time is elapsed, the Orion Smart activates the Float stage.
- Float: During this stage the float voltage is applied to the battery to maintain a fully-charged state. When the battery voltage drops below Re-bulk voltage during at least 1 minute, a new charge cycle will be triggered.
-
Input Voltage shows the voltage measured on the input terminals of the device.
-
Output voltage shows the voltage measured on the output terminals of the device.
- When the Orion Smart is on Off state, it will not measure the output voltage, so this value will appear as ‘—’
-
Off Reason shows the reason why the Orion Smart is disabled (appears under the “Charger State” text when the Orion Smart is Off)
Charger Mode – GRAPH tab
- Orion Smart [SERIAL NUMBER] confirms the connected device. A custom name can also be set if desired.
- Charger State Graph indicate in which state the charger currently is and show a short description of the current state.
Power Supply Mode
- Orion Smart [SERIAL NUMBER] confirms the connected device. A custom name can also be set if desired.
- Mode icon shows in which mode the Orion Smart is operating (Power Supply in this case)
- Input Voltage shows the voltage measured on the input terminals of the device
- Output voltage shows the voltage measured on the output terminals of the device
- When the Orion Smart is on Off state, it will not measure the output voltage, so this value will appear as ‘—’
- Off Reason shows the reason why the Orion Smart is disabled (appears under the “Power Supply Mode” text when the Orion Smart is disabled)
Settings
VictronConnect allows the user to change and adjust several different settings
from the Orion Smart. This is done through the settings option that can be
accessed by clicking the icon on the right top corner of the screen. The
settings options are different according to the operation mode that is
selected.
Charger Mode
When on Charger Mode, these are the available settings.
- Function allow to choose between “Charger” or “Power supply”. When charger mode is selected, the Orion Smart will follow the three state charge algorithm. For more information about the charge algorithm, please read the Orion Smart manual.
- Battery settings allow to change the battery settings in order to adjust the absorption voltage, float voltage and others to fit the battery being charged. The battery setting is explained better on the next item.
- Input voltage lock-out allow to choose between two thresholds. One to set the lock-out and another one to reset it. Normally, a minimum 0.5V (for 12V input Orion Smart) difference is used for a better performance. The protection can still be disabled if desired by the user. For more information about the input voltage lock-out, please read the Orion Smart manual.
- Engine shutdown detection allow to choose between two thresholds. One to set the detect the engine shutdown and another one to detect when it is running. Normally, a minimum 0.2V (for 12V input Orion Smart) difference is used for a better performance. The engine shutdown detection can still be disabled if desired by the user. For more information about the engine shutdown detection, please read the Orion Smart manual.
Charger Mode – Battery Settings
- Charger enabled
- Toggling this setting turns the Orion Smart off. The batteries will not be charged.
- Charger settings – Battery preset
- Battery preset allows to select the battery type; accept factory defaults; or enter your own preset values to be used for the battery charge algorithm. The Absorption voltage, Float voltage, Bulk time limit, Re-bulk voltage offset, Adaptive absorption time and Absorption time, settings are all configured to a preset value – but can be user-defined.
- User-defined presets can be stored in the preset library – in this way installers will not have to define all the values each time they are configuring a new installation.
- By selecting Edit Presets, custom parameters can be set as follows:
- Absorption voltage
- Set the absorption voltage
- Float voltage
- Set the float voltage
- Bulk time limit
- Set the maximum bulk time allowed for the charger.
- Re-bulk offset voltage
- The re-bulk offset voltage determines what is the offset between the float voltage (or absorption if it is lower) and the re-bulk voltage. The re-bulk voltage is the battery voltage threshold that triggers another charge cycle. For example, when the charger cannot maintain the battery voltage due to a high load, the battery voltage will fall and a new charge cycle will be started once the battery voltage drops below the re-bulk voltage.
- Absorption time
- The absorption time depends on if the Adaptive absorption time algorithm will be used or not. If that setting is not set, the charger will use a Fixed absorption time, selected by the user. Now, if the adaptive absorption time is set, then the charger will determine the absorption time based on the bulk elapsed time of that charge cycle, the Maximum absorption time in this case is also set by the user.
Power Supply Mode
When on Power Supply Mode, these are the available settings.
- Function allow to choose between “Charger” or “Power supply”. When power supply mode is selected, the Orion Smart will keep the output voltage as set on the setting.
- Output voltage allow to choose the output voltage when power supply mode is selected. Note that the minimum and maximum voltages needs to be within the product limit (i.e.: 10V to 15V for 12V output Orion Smart)
- Input voltage lock-out allow to choose between two thresholds. One to set the lock-out and another one to reset it. Normally, a minimum 0.5V (for 12V input Orion Smart) difference is used for a better performance. The protection can still be disabled if desired by the user. For more information about the input voltage lock-out, please read the Orion Smart manual.
Product Information
By clicking the button on the top right of the settings menu, it is possible
to access the product information screen. See image below.
- Product shows the Orion Smart model
- Serial number shows the serial number of the unit
- Pin code allow the pin code to be changed. This is recommended to be done so settings and information won’t be easy to access
- Custom name allow the product custom name to be changed to what the user wants. As default, it shows a short product name “Orion Smart” plus the serial number
- Firmware shows the current firmware version installed on the device and also allow the user to update the charger if desired
- Bootloader shows the bootloader firmware version
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>