inELs RFSC-61N Switching Socket Instruction Manual
- June 9, 2024
- inELS
Table of Contents
02-158/2021 Rev.0
RFSC-61N
Switching socket
RFSC-61N Switching Socket
WARNING
- Newly produced drivers work in the RFIO 2 data protocol mode. These driv- ers are loaded in the actuators in a different way than before. Among other things, it eliminates the risk of inadvertently loading another randomly occurring controller within range.
- Drivers can still be switched to so-called compatibility mode, and loaded in a simpler (older way)
- The mode in which the controller is located is indicated after inserting the battery and after 5 seconds have passed, at which the LED is lit by subsequent different intervals of flashing of the LED.
RFIO 2 mode
= Double flash (flash, flash, gap, flash, flash)
Compatibility mode
= Flash fast (flash, flash, flash, flash, flash)
- If you do not want to change the function of the controller, you must not press any buttons during this time.
- If we need to change the operating mode of the controller, after inserting the battery, when the LED is permanently lit, we press at the same time:
- button 1 and 3 on RF KEY-40/60
- button 1 and 2 on RFWB-20/40
- button 1 and 2 on RFGB-20/40
- button 1 and 2 on RF KEY
you hold the buttons until the LED starts to signal the changed mode (double fl
ash or fast fl ash).
After that, the buttons must be released. The selected mode of the function is
stored in memory and after replacing the battery, the controller continues to
operate in the same mode.
NOTE: after each removal of the battery, we press one of the buttons
several times to discharge the device and reinsert the battery
UPDATE THE CONTROLLER ACTUATORS IN RFIO MODE
If the controller is used in RFIO 2 mode, then to update the controller
actuators, it is necessary to switch not only the actuator to the update mode
(according to the instructions for the actuator), but also the controller in
the following way: You remove the battery from the controller, press some of
the buttons several times to discharge the device, and reinsert the battery.
At the moment when the LED lights up, you press the 1 button and hold it down
until the controller starts signaling the updating mode with a short fl ashing
of the LED. Then you release the button and the controller now works in RFIO 2
update mode. To end the update mode, you remove the battery, press one of the
buttons several times, and then reinsert the battery. Now you do not press any
button and the controller starts again in RFIO 2 operating mode,
Characteristics
- The switched socket with 1 output channel is used to control fans, lamps, heaters and appliances, which are connected by a power cord.
- They can be combined with detectors, controllers, iNELS RF Control or system components.
- Thanks to the socket design, installation is simple by direct insertion into the existing socket.
- It enables connection of the switched load up to 16A (4.000 W).
- Multi-function design – button, impulse relay and time function of delayed ON or OFF with time setting of 2s-60 min.
- The switched socket may be controlled by up to 32 channels (1 channel represents 1 button on the controller).
- The programming button on the socket is also used for manual control of the output.
- Memory status can be pre-set in the event of a power failure.
- Range up to 200 m (in open space), if the signal is insufficient between the controller and unit, use the signal repeater RFRP-20 or protocol component RFIO 2 that support this feature.
- Communication frequency with bidirectional protocol iNELS RF Control 2 (RFIO 2 ).
Assembly
Indication, manual control
Radio frequency signal penetration through various construction materials
| | | |
---|---|---|---|---
60 – 90 %| 80 – 95 %| 20 – 60 %| 0 – 10 %| 80- 90 %
brick walls| wooden structures with plaster boards| reinforced concrete| metal
partitions| common glass
Compatibility
The device can be combined with all system components, controls and devices of
iNELS RF
Control and iNELS RF Control 2 .
The detector can be assigned an iNELS RF Control 2 (RFIO 2) communication
protocol.
Functions and programming with RF transmitters
Function button
Description of button
The output contact will be closed by pressing the button and opened by
releasing the button.
For the correct execution of individual commands (press = closing / releasing
the button = opening), the time delay between these commands must be a min of
. 1s (press – delay 1s – release).
Programming
Press of programming button on receiver RFSC-61N for 1 second will activate
receiver RFSC-61N into programming mode. LED is fl ashing in 1s interval.
Select and press one button on wireless switch, to this button will be
assigned function Button. Press of programming button on receiver RFSC-61N
shorter then 1 second will fi nish programming mode. The LED lights up
according to the preset memory function.
Function switch on
Description of switch on
The output contact will be closed by pressing the button.
Programming Press of programming button on receiver RFSC-61N for1 second
will activate receiverRFSC-61N into programmingmode. LED is flashing in
1sinterval.
Two presses of your selected button on the RF transmitter assigns the function
switch on must be a lapse of 1s between individual presses). Press of
programming button on receiver RFSC-61N shorter then 1 second will fi nish
programming mode. The LED lights up according to the preset memory function.
Function switch off
Programming Press of programming button on receiver RFSC-61N for 1 second will activate receiver RFSC-61N into programming mode. LED is fl ashing in 1s interval. Three presses of your selected button on the RF transmitter assigns the function switch off (must be a lapse of 1s between individual presses).
Press of programming button on receiver RFSC-61N shorter then 1 second will fi
nish programming mode. The LED lights up according to the preset memory
function.
Function impulse relay
Description of impulse rela The output contact will be switched to the
opposite position by each press of the button. If the contact was closed, it
will be opened and vice versa.
Programming Press of programming button on receiver RFSC-61N for 1 second
will activate receiver RFSC-61N into programming mode. LED is fl ashing in 1s
interval.
Four presses of your selected button on the RF transmitter assigns the
function impulse relay (must be a lapse of 1s between individual presses).
Press of programming button on receiver RFSC-61N shorter then 1 second will fi
nish programming mode. The LED lights up according to the preset memory
function.
Funcion delayed off
Description of delayed off The output contact will be closed by pressing the
button and opened after the set time interval has elapsed.
Programming
setting time delay 2s … 60min. Press of programming button on receiver RFSC-
61N for 1 second will activate receiver RFSC-61N into programming mode. Red
LED is fl ashing in 1s interval. Assignment of the delayed off function is
performed by fi ve presses of the selected button on the RF transmitter (must
be a lapse of 1s between individual presses). Press of programming button
longer then 5 seconds, will activate actuator into timing mode. LED fl ashs 2x
in each 1s interval. Upon releasing the button, the delayed return time starts
counting.
After the desired time has elapsed (range of 2s … 60min), the timing mode ends
by pressing the button on the RF transmitter, to which the delayed return
function is assigned. This stores the set time interval into the actuator
memory. Press of programming button on receiver RFSC-61N shorter then 1 second
will fi nish programming mode. The LED lights up according to the preset memory
function.
setting the number of hours of delay in hourly intervals – 1h … 10h Press
of programming button on receiver RFSC-61N for 1 second will activate receiver
RFSC-61N into programming mode. Red LED is flashing in 1s interval. Assignment
of the delayed off function is performed by fi ve presses of the selected button
on the RF transmitter (must be a lapse of 1s between individual presses).
Pressing the PROG button for longer than 8 seconds brings the socket into the timing mode. The LED will give a single fl ash 3x and a double fl ash 3x, then goes out.
By the number of presses of the selected RF transmitter button, set the
required delay (1 press – 1h, … 10 presses – 10h). Each press on the RF
transmitter is indicated by a fl ash of the LED on the socket RFSC-61N. Press
of programming button on receiver RFSC-61N shorter then 1 second will finish
programming mode. The LED lights up according to the preset memory function.
Note: modes 2s – 60min and 1 hr up to 10 hr cannot be combined.
Function delayed on
Description of delayed on The output contact will be opened by pressing the
button and closed after the set time interval has elapsed.
Programming
setting time delay 2s … 60min. Press of programming button on receiver RFSC-
61N for 1 second will activate receiver RFSC-61N into programming mode. LED is
fl ashing in 1s interval.
Assignment of the delayed on function is performed by six presses of the selected button on the RF transmitter (must be a lapse of 1s between individual presses).
Press of programming button longer then 5 seconds, will activate actuator into
timing mode. LED flashs 2x in each 1s interval. Upon releasing the button, the
delayed return time starts counting. After the desired time has elapsed (range
of 2s … 60min), the timing mode ends by pressing the button on the RF
transmitter, to which the delayed on function is assigned. This stores the set
time interval into the actuator memory. Press of programming button on
receiver RFSC-61N shorter then 1 second will fi nish programming mode. The LED
lights up according to the preset memory function.
setting the number of hours of delay in hourly intervals – 1h … 10h Press
of programming button on receiver RFSC-61N for 1 second will activate receiver
RFSC-61N into programming mode. LED is fl ashing in 1s interval. Assignment of
the delayed on function is performed by six presses of the selected button on
the RF transmitter (must be a lapse of 1s between individual presses).
Pressing the PROG button for longer than 8 seconds brings the socket into the
timing mode. The LED will give a single fl ash 3x and a double flash 3x, then
goes out. By the number of presses of the selected RF transmitter button, set
the required delay (1 press – 1h, … 10 presses – 10h). Each press on the RF
transmitter is indicated by a
flash of the LED on the socket RFSC-61N. Press of programming button on
receiver RFSC-61N shorter then 1 second will fi nish programming mode. The LED
lights up according to the preset memory function.
Note: modes 2s – 60min and 1 hr up to 10 hr cannot be combined.
The address listed on the rear of the socket is used for programming and
controlling sockets RFSC-61N by RF control units.
Deleting the socket
Deleting one position of the transmitter
By pressing the programming button on the actuator for 5 seconds, deletion of
one transmitter activates. LED fl ashs 4x in each 1s interval. Pressing the
required button on the transmitter deletes it from the actuator’s memory. To
confi rm deletion, the LED will confi rm with a fl ash long and the component
returns to the operating mode. The memory status is not indicated. Deletion
does not aff ect the pre-set memory function.
Deleting the entire memory By pressing the programming button on the
actuator for 8 seconds, deletion occurs of the actuator’s entire memory. LED fl
ashs 4x in each 1s interval. The actuator goes into the programming mode, the
LED flashes in 0.5s intervals (max. 4 min.). You can return to the operating
mode by pressing the Prog button for less than 1s. The LED lights up according
to the pre-set memory function and the component returns to the operating
mode. Deletion does not aff ect the pre-set memory function.
Selecting the memory function Press of programming button on receiver
RFSC-61N for 1 second will activate receiver RFSC-61N into programming mode.
LED is fl ashing in 1s interval.
Pressing the programming button on the RFSC-61N receiver for less than 1 second will fi nish the programming mode, this will reverse the memory function. The LED lights up according to the current pre-set memory function. The set memory function is saved. Every other change is made in the same way.
-
Memory function on:
– For functions 1-4, these are used to store the last state of the relay output before the supply voltage drops, the change of state of the output to the memory is recorded 15 seconds after the change.
– For functions 5-6, the target state of the relay is immediately entered into the memory after the delay, after re-connecting the power, the relay is set to the target state. -
Memory function off: When the power supply is reconnected, the relay remains off.
Technical parameters
Supply voltage: | 230 V AC |
---|---|
Supply voltage frequency: | 50-60 Hz |
Apparent power: | 7 VA / cos φ = 0.1 |
Dissipated power: | 0.7 W |
Supply voltage tolerance: | +10 %; -15 % |
Output | |
Number of contacts: | 1x switching / przełączany (AgSnO2 ) |
Rated current: | 16 A / AC1 |
Switching power: | 4000 VA / AC1 |
Peak current: | 30 A / <3 s |
Switching voltage: | 250 V AC1 |
Min. switching power DC: | 500 mW |
Mechanical service life: | 10×10 6 |
Electrical service life (AC1): | 0.7×10 5 |
Control | |
Wirelessly: | 32 chanels (buttons) / do 32 kanałów (poprzez przyciski) |
Communication protocol: | RFIO 2 |
Frequency: | 866–922 MHz |
Function repeater: | ne / nie |
Manual control: | button / przycisk PROG (ON/OFF) |
Range: | up to / do 200 m |
Other data | |
Operating temperature: | -15… + 50 °C |
Working position: | any/ dowolna |
Mounting: | plug into a socket / przez podłączenie do gniazda |
Protection: | IP30 |
Overvoltage category: | III. |
Contamination degree: | 2 |
Dimensions: | 63 x 110 x 74 mm |
Weight: | 129 g |
Related standards: | EN 60730, EN 63044, EN 300 220, EN 301 489 |
Attention: When you instal iNELS RF Control system, you have to keep
minimal distance 1 cm between each units.
Between the individual commands must be an interval of at least 1s.
Warning
Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Installation and connection can be carried out only by a person with adequate professional qualifi cation upon understanding this instruction manual and functions of the device, and while observing all valid regulations. Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regulations, norms, directives and professional, and export regulations for working with electrical devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe correct location of RF components in a building where the installation is taking place. RF Control is designated only for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is then impossible. RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an obstruction, interfered, battery of the transceiver can get fl at etc. and thus disable remote control.
ELKO EP, s.r.o. | Palackého 493
769 01 Holešov, Všetuly
Czech Republic
e-mail: elko@elkoep.com
Support: +420 778 427 366
ELKO EP Poland, sp. z o. o.
ul. Motelowa 21 | 43-400 Cieszyn
Polska | e-mail: elko@elkoep.pl
GSM: +48 785 431 024
www.elkoep.com
www.elkoep.pl
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>