iNELS RFSAI-xB-SL Switch Unit with Input For External Button User Manual
- October 30, 2023
- inELS
Table of Contents
iNELS RFSAI-xB-SL Switch Unit with Input For External Button
Characteristics
- The switching component with one/two output relays is used to control appliances and lights. Switches/buttons connected to the wiring can be used for control.
- They can be combined with Detectors, Controllers or iNELS RF Control System Components.
- The BOX version off ers installation directly in the installation box, ceiling or cover of the controlled appliance. Easy installation thanks to screwless terminals.
- It allows the connection of switched loads with a total sum of 8 A (2000 W).
- Functions : for RFSAI 61B-SL and RFSAI 62B-SL – pushbutton, impulse relay and time functions of delayed start or return with time setting 2 s-60 min. Any function can be assigned to each output relay. For RFSAI-11B-SL, the button has a fi xed function – ON / OFF.
- The external button is assigned in the same way as the wireless one.
- Each of the outputs can be controlled by up to 12/12 channels (1-channel represents one button on the controller). Up to 25 channels for RFSAI-61B-SL and RFSAI-11B-SL.
- The programming button on the component also serves as a manual output control.
- Possibility to set the output status memory in case of failure and subsequent power recovery.
- The elements of the repeater can be set for the components via the RFAF / USB service device, PC, application.
- Range up to 200 m (outdoors), in case of insuffi cient signal between the controller and the device, use the RFRP-20 signal repeater or component with the RFIO2 protocol that support this function.
- Communication with bidirectional RFIO2 protocol.
- The contact material of the AgSnO2 relay enables switching of light ballasts.
Assembly
- mounting in an installation box / (even under the existing button / switch)
- mounting into the light cover
- ceiling mounted
Connection
Screwless terminals
Radio frequency signal penetration through various construction materials
Indication, manual control
-
LED / PROG button
-
LED green V1 – device status indication for output 1
-
LED red V2 – device status indication for output 2.
Indicators of memory function: -
On – LED blinks x 3.
-
Off – The LED lights up once for a long time.
-
Manual control is performed by pressing the PROG button for<1s.
-
Programming is performed by pressing the PROG button for 3-5s.
-
Terminal block – connection for external button
-
Terminal block – connecting the neutral conductor
-
Terminal block – load connection with the sum of the total current 8A (eg V1=6A, V2=2A)
-
Terminal block for connecting the phase conductor
In the programming and operating mode, the LED on the component lights up at the same time each time the button is pressed – this indicates the incoming command. RFSAI-61B-SL: one output contact, status indication by red LED
Compatibility
The device can be combined with all system components, controls and devices of iNELS RF Control and iNELS RF Control2. The detector can be assigned an iNELS RF Control2 (RFIO2) communication protocol.
Channel selection
Channel selection (RFSAI-62B-SL) is done by pressing the PROG buttons for
1-3s. RFSAI-61B-SL: press for more than 1 second. After button release, LED is
flashing indicating the output channel: red (1) or green (2). All other
signals are indicated by corresponding color of LED for each channel.
Function button
Description of button
The output contact will be closed by pressing the button and opened by
releasing the button. For the correct execution of individual commands (press
= closing / releasing the button = opening), the time delay between these
commands must be a min of . 1s (press – delay 1s – release).
Programming
Function switch on
Description of switch on
The output contact will be closed by pressing the button.
Programming
Function switch off
Description of switch off
The output contact will be opened by pressing the button.
Programming
Press of programming button on receiver RFSAI-62B for 3-5 s (RFSAI- 61B-SL:
press for more than 1 s) will activate receiver RFSAI-62B into programming
mode. LED is flashing in 1s interval.
Function impulse relay
Description of impulse relay
The output contact will be switched to the opposite position by each press
of the button. If the contact was closed, it will be opened and vice versa.
Programming
Funcion delayed off
Description of delayed off
The output contact will be closed by pressing the button and opened after
the set time interval has elapsed.
Programming
Function delayed on
Description of delayed on
The output contact will be opened by pressing the button and closed after
the set time interval has elapsed.
Programming
Programming with RF control units
Addresses listed on the front side of the actuator are used for programming
and controlling the actuator and individual RF channels by control units.
Delete actuator
Deleting one position of the transmitter
By pressing the programming button on the actuator for 8 seconds (RFSAI-61B-
SL: press for 5 second), deletion of one transmitter activates. LED flashs 4x
in each 1s interval. Pressing the required button on the transmitter deletes
it from the actuator’s memory. To confirm deletion, the LED will confirm with
a flash long and the component returns to the operating mode. The memory
status is not indicated. Deletion does not affect the pre-set memory function.
Deleting the entire memory
By pressing the programming button on the actuator for 11 seconds (RFSAI-61B-
SL: press for more than 8 second), deletion occurs of the actuator’s entire
memory. LED flashs 4x in each 1s interval. The actuator goes into the
programming mode, the LED flashes in 0.5s intervals (max. 4 min.). You can
return to the operating mode by pressing the Prog button for less than 1s. The
LED lights up according to the pre-set memory function and the component
returns to the operating mode. Deletion does not aff ect the pre-set memory
function.
Selecting the memory function
Press of programming button on receiver RFSAI-62B for 3-5 second (RFSAI-61B-
SL: press for 1 second) will activate receiver RFSAI- 62B into programming
mode. LED is flashing in 1s interval.
Press of programming button on receiver RFSAI-62B for 3-5 second (RFSAI-61B- SL: press for 1 second) will activate receiver RFSAI- 62B into programming mode. LED is flashing in 1s interval.
- Memory function on:
- For functions 1-4, these are used to store the last state of the relay output before the supply voltage drops, the change of state of the output to the memory is recorded 15 seconds after the change.
- For functions 5-6, the target state of the relay is immediately entered into the memory after the delay, after re-connecting the power, the relay is set to the target state.
- Memory function off:
When the power supply is reconnected, the relay remains off.
The external button RFSAI-62B-SL is programmed in the same way as for wireless. RFSAI-11B-SL it is not programmed, it has a fixed function.
Technical parameters
RFSAI-11B-SL RFSAI-61B-SL RFSAI-62B-SL
Supply voltage: | 230 V AC |
---|---|
Supply voltage frequency: | 50-60 Hz |
Apparent input: | 7 VA / cos φ = 0.1 |
Dissipated power: | 0.7 W |
Supply voltage tolerance: | +10 %; -15 % |
Output | |
Number of contacts: | 1x switching / 1x kapcsoló |
Rated current: | A / AC1 |
Switching power: | 2000 VA / AC1 |
Peak current: | 10 A / <3 s |
Switching voltage: | 250 V AC1 |
Mechanical service life: | 1×107 |
Electrical service life (AC1): | 1×105 |
Control | |
Wireless: | 25-channels/ 25 csatorna 2 x |
12-channels/2×12 csatorna
Number of functions:| 1| 6| 6
Communication protocol:| RFIO2
Frequency:| 866–922 MHz (for more information see p. 74)/ 866–922 MHz (lásd a
74. oldalon)
Repeater function:| yes/ Igen
Manual control:| button PROG (ON/OFF)/ PROG gomb (ON/OFF)
External button / switch: Range:| yes/ Igen
Other data| in open space up to 200 m/ nyílt térben 200 m-ig
Operating temperature:|
Operating position:| -15 až + 50 °C
Operating position:| any/ Bármi
Mounting:| free at lead-in wires/ laza a tápvezetékeken
Protection:| IP40
Overvoltage category:| III.
Contamination degree:| 2
Connection:| screwless terminals/ csavar nélküli bilincsek
Connecting conductor:| : 0.2-1.5 mm2 solid/flexible/ 0.2-1.5 mm2
szilárd/rugalmas
Dimensions:| 43 x 44 x 22 mm
Weight:| 31g| 45 g
Related standards:| EN 60730, EN 63044, EN 300 220, EN 301 489
Control button input is at the supply voltage potential.
Attention:
When you instal iNELS RF Control system, you have to keep minimal distance 1
cm between each units. Between the individual commands must be an interval of
at least 1s.
Warning
Instruction manual is designated for mounting and also for user of the device.
It is always a part of its packing. Installation and connection can be carried
out only by a person with adequate professional qualifi cation upon
understanding this instruction manual and functions of the device, and while
observing all valid regulations. Trouble-free function of the device also
depends on transportation, storing and handling. In case you notice any sign
of damage, deformation, malfunction or missing part, do not install this
device and return it to its seller. It is necessary to treat this product and
its parts as electronic waste after its lifetime is terminated. Before
starting installation, make sure that all wires, connected parts or terminals
are de-energized. While mounting and servicing observe safety regulations,
norms, directives and professional, and export regulations for working with
electrical devices. Do not touch parts of the device that are energized – life
threat. Due to transmissivity of RF signal, observe correct location of RF
components in a building where the installation is taking place. RF Control is
designated only for mounting in interiors. Devices are not designated for
installation into exteriors and humid spaces. The must not be installed into
metal switchboards and into plastic switchboards with metal door –
transmissivity of RF signal is then impossible. RF Control is not recommended
for pulleys etc. – radiofrequency signal can be shielded by an obstruction,
interfered, battery of the transceiver can get fl at etc. and thus disable
remote control.
ELKO EP declares that the RFSAI-xxB-SL type of equipment complies with Directives 2014/53/EU, 2011/65/EU, 2015/863/EU and 2014/35/EU. The full EU
Declaration of Conformity is at:
- https://www.elkoep.com/switching-units-with-inputs-for-external-buttons—-rfsai-11b-sl
- https://www.elkoep.com/switching-units-with-inputs-for-external-buttons—-rfsai-61b-sl
- https://www.elkoep.com/switching-units-with-inputs-for-external-buttons—rfsai-62b-sl
ELKO EP, s.r.o., Palackého 493, 769 01 Holešov, Všetuly, Czech Republic
- Tel.: +420 573 514 211
- e-mail : elko@elkoep.com
- www.elkoep.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>