iNELS RFDW-71 Glass Control Panel with Dimmer User Manual

May 15, 2024
inELS

RFDW-71, RFDW-271
Glass controller with dimmer
iNELS RFDW-71 Glass Control Panel with Dimmer - icon

Characteristics

  • The glass design controller with dimmer and touch buttons is used to control light sources:
    R – classic lamps (resistive load)
    L – halogen lamps with wound transformer (inductive load)
    C – halogen lamps with electronic transformer (capacity load)
    ESL – dimmable energy-effi cient fl uorescent lamps
    LED – LED light sources (230 V) equipped with LED.

  • The touch buttons on the circuit breaker allow you to directly control the integrated dimmer as well or other components of the installation.

  • The backlight intensity (white LED) of the buttons is automatically adjusted depending on the ambient lighting.

  • They can be combined with detectors, controllers, iNELS Wireless or system components for output control from other locations.

  • 8 light functions – smooth increase or decrease with time setting 2 s – 30 min. Function description can be found on page 73.

  • When switched off , the set level is stored in the memory, and when switched back on, it returns to the most recently set value.

  • Thanks to setting the min. brightness you will eliminate fl ashing of the LED and ESL light sources.

  • The universal dimmer may be controlled by up to 25-channels.

  • Possibility to set the memory status in case of power failure.

  • Range up to 160 m (in open space), if the signal is insuffi cient between the controller and unit, use the signal repeater RFRP-20 or protocol component RFIO2 that support this feature.

  • Assigning the controller to the elements of the iNELS Wireless system is done using the pairing button on the controller.

Description

iNELS RFDW-71 Glass Control Panel with Dimmer -
Description Conection

iNELS RFDW-71 Glass Control Panel with Dimmer -
Conection

Settings

RFDW-71 consists of two independent units:

  1. Glass control panel with 4 pushbuttons behaves as the RFWB-40 version RFIO 2 and may be used as the RFWB-40 pushbuttons to control other units or control of a RFDW-71 dimmer.
  2. The lower part in the BOX is an independent dimmer with the RFDEL-71 functions; it can be controlled using system elements (ELAN, RF Touch) or RFWB, RFKEY controllers or using the glass control panel.

Pairing buttons with the built-in dimmer is done as described in section A
Pairing the controller buttons to other elements is done as described in section B
Setting the backlight, sound and light indication of the buttons, selection of the load type
Hold the PROG pushbutton pressed and in a quick sequence, press the pushbuttonsiNELS RFDW-71 Glass Control Panel with Dimmer - icon
2.
Then release the PROG pushbutton. Green LED lights up
Quick pressing of the PROG pushbutton opens the backlight setting mode and clicking of the pushbuttons. This mode is indicated by the red LED.
The pushbutton switches on/off the adaptive backlight illumination of the pushbuttons.
The pushbutton  switches on/off complete backlight illumination of the pushbuttons.
The pushbutton switches on/off the acoustic indication of pressing of the pushbuttons.
Other pressing of the PROG pushbutton opens the mode for setting of the load type and min. of brightness. This mode is indicated by simultaneous lighting of the red and green LEDs.
Minimal brightness can be set using pushbuttons .
The pushbutton selects control type RC, the pushbutton selects control type L.
Other pressing of the PROG pushbutton closes the SETUP mode.

Pairing buttons with built-in dimmer

The PROG pushbutton is located on the left, between the pushbuttons and . This pushbutton is connected to the RFDW-71 dimmer and using this pushbutton, you can activate the learning or deletion modes and switch over the memory mode. The learning modes are indicated by a red LED. In the learning mode, the RFWB, RFKEY controllers or pushbuttons on the glass panel can be learnt to the RFDW-71 dimmer memory. In case the RFDW-71 dimmer receives a command from the controller, it indicates this by a fl ash of the red LED. Long press (>1s) of the PROG button (see. Tab 1)iNELS RFDW-71 Glass Control Panel with Dimmer -
Pairing buttons 2Short press (<1s) of the selected button on the controller (number of presses = function) Short press (<1s) of the PROG button to close

Pairing the buttons of the controller to other RF elements

Hold the PROG pushbutton pressed and in a quick sequence, press the pushbuttons iNELS RFDW-71 Glass Control Panel with Dimmer - icon
9and . Then release the PROG pushbutton.
The green LED now indicates the mode for sending of learning codes of the pushbuttons to .
This enables use of these pushbuttons to control other RF elements instead of the RFDW-71 dimmer.
RF elements must support pairing without compatibility mode (RFIO2)
Press (1s), Short press (<1s), Long press (>1s ) Hold down the PROG button and press buttons 1,2,3,4 in quick succession. Long press (>1s) of the PROG button (see. Tab 1) Short press (<1s) of the selected button on the controller (number of presses = function) Short press (<1s) of the PROG button to close Short press (<1s) of the PROG button to close

Pairing without compatibility mode

First, insert the battery into the controller. If the battery has already been inserted into the controller, remove it and press some button to restore it to its default state. After inserting the battery, while the red LED is lit (3 s), press and hold 1 until the controller starts to indicate the driver mode by briefl y fl ashing the LED. Then release the button to make the controller ready for pairing. Next, hold down the PROG button on the device you want to control for 1, 2 or 3 s (see. Tab 1) continue to set functions 1 to 6 by pressing the appropriate button on the controller with the appropriate number of presses (see Tab 2). Finish programming by briefl y pressing the PROG button on the device and removing and reinserting the battery into the controller.
Pairing in compatibility mode cannot be used.
Table 1) Modes of the PROG button on the devices

Applies to| Applies to: Entering
pairing mode (Step 2)| Clearing channel/button
memory| Clear the memory of an
entire device
---|---|---|---
RFSA-11B, RFSAI-11B-SL, RFSA-61B, RFSA-61B-SL, RFSA-61M, RFSA-61MI, RFSA-66M, RFSA-66MI, RFSC-61, RFUS-61, RFDA-11B, RFDEL71B,
RFDEL-71M,
RFDEL-76M,
RFDALI-04B,
RFDALI-32B,
RFDA-73M/RGB,
RFDSC-71N| 1 s| 5 s| 8 s
RFSAI-62B-SL, RFSA-62B, RFSAI-62BRFSW-62, RFSW-262, RFDW-71, RFDW-271| 3 s| 7 s| 11 s
RFDAC-71B| 2 s| 5 s| 10 s

**Clear one driver from memory![iNELS RFDW-71 Glass Control Panel with Dimmer

  • assembly 6](https://manuals.plus/wp-content/uploads/2024/03/iNELS-RFDW-71 -Glass-Control-Panel-with-Dimmer-assembly-6.png) To clear an already paired channel to a button on the controller, press the PROG on the device for a period of time of 5 s or 7 s (see. Tab 1). Clear the memory of the button and press the appropriate button on the controller that you want to unpair. After this step, the item returns to its working state.
    Clear the memory of the whole device If you want to clear the memory of the whole device (unpair all buttons or delete all channels at once, press the PROG button on the device for 8/10/11 s according to the type of device (see. Tab 1). Clearing the memory of the entire device. The device remains in pairing mode.
    Memory function selection Press of programming button on receiver RFDW-71 for 1 second will activate receiver into programming mode. LED is flashing in 1s interval.
    Indication of the memory function:
    On – LED 3x flashes
    off** – LED 1 x long flash Pressing the programming button on the receiver for less than 1 second will fi nish the programming mode, this will reverse the memory function. The LED lights up according to the current preset memory function. The set memory function is saved. Every other change is made in the same way.

    • Memory function on:
      – For functions 1-4, 7, 8 used to store the last state of the relay output before a power supply failure, changing the state of the output relay is written to the memory 15s after the change is made.
      – For function 5-6, the target state of the output relay is instantly written to the memory after the timing of the delay had been entered, after the power supply is reconnected, the output relay is set to the target state.

    • Memory function off:
      When the power supply is reconnected, the output remains off.

Technical parameters

Power supply

Supply voltage: 230 V AC / 50-60 Hz
Apparent power: 1.1 VA
Dissipated power: 0.8 W
Supply voltage tolerance: ±10 %
Dimmed load: R,L,C, LED, ESL

Output

Contactless: 2 x MOSFET
Load capacity: max. 160 W

Control

Wireless: up to 25-channels (buttons)
Communication protocol: RFIO2
Frequency: 866–922 MHz
Repeater function: yes
Manual control: 4 touch keys, button PROG
Button backlight: white LED with intensity change
Indications PROG: red/green LED
Range: in open space up to 160 m

Connection

Max. cable size (mm2): screwless clamps 0.2 – 1.5 mm2

Other data

Operating temperature: (14 °F .. 104 °F) / -10 .. +40°C
Storing temperature: (–22 °F .. 158 °F) / -30 .. +70 °C
Protection degree: IP20
Overvoltage category: II.
Pollution degree: 2
Operation position: any
Installation: into installation box
Dimensions: 94 x 94 x 41 mm
Weight: 129 g

More detailed information can be found in the iNELS RF Control Installation Manual: https://www.elkoep.com/catalogs-and-brochures
ELKO EP, sro hereby declares that the type of radio equipment RFGB-20, RFGB-40, RFGB-220, RFGB-240 is in accordance with Directives 2014/53 / EU, 2011/65 / EU, 2015/863 / EU and 2014 / 35 / EU. The full text of the EU Declaration of Conformity is
available on the following websites:
https://www.elkoep.com/wireless-dimmer-switch-rfdw-71
https://www.elkoep.com/glass-touch-controller-brrfdw-271

Radio frequence signal penetration through various construction materialsiNELS RFDW-71 Glass Control Panel with Dimmer - assembly
10

| | | |
---|---|---|---|---
60 – 90 %| 80 – 95 %| 20 – 60 %| 0 – 10 %| 80- 90 %
brick walls| wooden structures with
plaster boards| reinforced concrete| metal partitions| common glass

Control options

RF controlers can control:

  • switches
    RFSA-11B, RFSA-61B, RFSA-62B, RFSA-61M, RFSA-66M, RFSAI-61B, RFSC-11, RFSC-61, RFUS-11, RFUS-61, RFJA-12B

  • dimmers
    RFDA-73/RGB, RFDA-11B, RFDA-71B, RFDEL-71B, RFDEL-71M, RFDSC-11, RFDSC-71, RFDAC-71B

  • lighting
    RF-RGB-LED-550, RF-White-LED-675

Safe handling

When handling a device unboxed it is important to avoid contact with liquids. Never place the device on the conductive pads or objects, avoid unnecessary contact with the components of the device.

Warning

Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Installation and connection can be carried out only by a person with adequate professional qualification upon understanding this instruction manual and functions of the device, and while observing all valid regulations. Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regulations, norms, directives and professional, and export regulations for working with electrical devices.Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe correct location of RF components in a building where the installation is taking place. RF Control is designated only for mounting in interiors. The must not be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is then impossible. RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an obstruction, interfered, battery of the transceiver can get flat etc. and thus disable remote control.

ELKO EP, s.r.o. | Palackého 493
769 01 Holešov, Všetuly
Česká republika | e-mail:elko@elkoep.cz
Support: +420 777 356 466
www.elkoep.com

Made in Czech Republic

Documents / Resources

| iNELS RFDW-71 Glass Control Panel with Dimmer [pdf] User Manual
RFDW-71, RFDW-271, RFDW-71 Glass Control Panel with Dimmer, Glass Control Panel with Dimmer, Control Panel with Dimmer, Panel with Dimmer
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

inELS User Manuals

Related Manuals