RFSAI-61B Wireless Switch Unit

The RFSAI-61B Wireless Switch Unit is a device that allows for wireless control of electrical circuits. It can be mounted in an installation box or into a light cover and is compatible with all system components, controls, and devices of iNELS RF Control and iNELS RF Control2. The device operates on various voltage inputs such as 230V, 120V, and 24V, as well as 12-24 V AC/DC. It uses radio frequency signals to penetrate through various construction materials such as brick walls, wooden structures with plaster boards, reinforced concrete, metal partitions, and common glass. The device has an LED that lights up when a command is received, and it can be programmed using a programming button on the receiver.

Product Usage Instructions

  1. To install the device, follow the assembly and mounting instructions provided in the installation manual. The device can be mounted in an installation box or into a light cover.
  2. Connect the device to a power source by connecting the L and N wires of the input voltage to the appropriate terminals on the device.
  3. Pair the device with a compatible transmitter by programming it using the programming button on the receiver. Press the programming button for one second to activate programming mode, and then press the button on the transmitter that you want to assign a function to. The LED on the device will flash in 1-second intervals to indicate that it is in programming mode. Pressing the programming button again for less than one second will finish programming mode, and the LED will light up according to the preset memory function.
  4. To use the device, press the button on the transmitter that is assigned to the function you want to activate. The LED on the device will light up to indicate that a command has been received.

For more detailed instructions and information on programming and usage, refer to the Installation manual iNELS RF Control available at http://www.elkoep.com/catalogs-and-brochures.

Characteristics

  • The switching unit with 1 output channel is used for controlling appliances and lights. It is possible to connect the existing button to the internal terminal in the wiring.
  • They can be combined with detectors, controllers, iNELS RF Control or system components..
  • The BOX design lets you mount it right in an installation box, a ceiling or controlled appliance cover.
  • It enables connection of the switched load up to 16A (4.000 W).
  • Function: button, impulse relay and time function of delayed start or return with time setting range of 2s-60min.
  • External button is programmed as a wireless button.
  • Input is not galvanic isolated!
  • The switching unit may be controlled by up to 25 channels (1 channel represents 1 button on the controller).
  • The programming button on the unit is also used for manual control of the output.
  • Memory status can be pre-set in the event of a power failure.
  • For components labelled as iNELS RF Control2 (RFIO2), it is possible to set the repeater function via the RFAF/USB service device.
  • Range up to 200 m (in open space), if the signal is insufficient between the controller and unit, use the signal repeater RFRP-20 or protocol component RFIO2 that support this feature.
  • Communication frequency with bidirectional protocol iNELS RF Control (RFIO2).

Assembly

  • Mounting in an installation box
    • (even under the existing button / switch)
  • mounting into the light cover
  • ceiling mounted

Connection

  • RFSAI-61B/230V
  • RFSAI-61B/120V
  • RFSAI-61B/24V

Construction materials

Radio frequency signal penetration through various construction materials

For more information, see “Installation manual iNELS RF Control”: http://www.elkoep.com/catalogs-and-brochures

Indication, manual control

  • Terminal board – connection for external button.
  • LED STATUS – indication of the device status.
    • Indicators of memory function:
    • On – LED blinks x 3.
    • Off – The LED lights up once for a long time.
  • Manual control is performed by pressing the PROG button for less than 1s.
  • Programming is performed by pressing the PROG button for more than 1s.

In the programming and operating mode, the LED on the component lights up at the same time each time the button is pressed – this indicates the incoming command.

Compatibility

  • The device can be combined with all system components, controls and devices of iNELS RF Control and iNELS RF Control2.
  • The detector can be assigned an iNELS RF Control2 (RFIO2) communication protocol.

Functions And Programming

Functions and programming with RF transmitters

Function button

Description of button

  • The output contact will be closed by pressing the button and opened by releasing the button.

Programming

  1. Press of programming button on receiver RFSAI-61B for 1 second will activate receiver RFSAI-61B into programming mode. LED is flashing in 1s interval.
  2. Select and press one button on wireless switch, to this button will be assigned function Button.
  3. Press of programming button on receiver RFSAI-61B shorter then 1 second will fi nish programming mode. The LED lights up according to the preset memory function.

Function switch on

Description of switch on

  • The output contact will be closed by pressing the button.

Programming

  1. Press of programming button on receiver RFSAI-61B for 1 second will activate receiver RFSAI-61B into programming mode. LED is flashing in 1s interval.
  2. Two presses of your selected button on the RF transmitter assigns the function switch on (must be a lapse of 1s between individual presses).
  3. Press of programming button on receiver RFSAI-61B shorter then 1 second will fi nish programming mode. The LED lights up according to the preset memory function.

Function switch off

Description of switch off

  • The output contact will be opened by pressing the button.

Programming

  1. Press of programming button on receiver RFSAI-61B for 1 second will activate receiver RFSAI-61B into programming mode. LED is flashing in 1s interval.
  2. Three presses of your selected button on the RF transmitter assigns the function switch off (must be a lapse of 1s between individual presses).
  3. Press of programming button on receiver RFSAI-61B shorter then 1 second will finish programming mode. The LED lights up according to the preset memory function.

Function impulse relay

Description of impulse relay

  • The output contact will be switched to the opposite position by each press of the button.
  • If the contact was closed, it will be opened and vice versa.

Programming

  1. Press of programming button on receiver RFSAI-61B for 1 second will activate receiver RFSAI-61B into programming mode. LED is flashing in 1s interval.
  2. Four presses of your selected button on the RF transmitter assigns the function impulse relay (must be a lapse of 1s between individual presses).
  3. Press of programming button on receiver RFSAI-61B shorter then 1 second will fi nish programming mode. The LED lights up according to the preset memory function.

Funcion delayed off

Description of delayed off

  • The output contact will be closed by pressing the button and opened after the set time interval has elapsed.

Programming

  1. Press of programming button on receiver RFSAI-61B for 1 second will activate receiver RFSAI-61B into programming mode. LED is flashing in 1s interval.
  2. Assignment of the delayed off function is performed by fi ve presses of the selected button on the RF transmitter (must be a lapse of 1s between individual presses).
  3. Press of programming button longer then 5 seconds, will activate actuator into timing mode. LED flashs 2x in each 1s interval. Upon releasing the button, the delayed return time starts counting.
  4. After the desired time has elapsed (range of 2s…60min), the timing mode ends by pressing the button on the RF transmitter, to which the delayed return function is assigned. This stores the set time interval into the actuator memory.
  5. Press of programming button on receiver RFSAI-61B shorter then 1 second will finish programming mode. The LED lights up according to the pre-set memory function.

Function delayed on

Description of delayed on

  • The output contact will be opened by pressing the button and closed after the set time interval has elapsed.

Programming

  1. Press of programming button on receiver RFSAI-61B for 1 second will activate receiver RFSAI-61B into programming mode. LED is flashing in 1s interval.
  2. Assignment of the delayed on function is performed by six presses of the selected button on the RF transmitter (must be a lapse of 1s between individual presses).
  3. Press of programming button longer then 5 seconds, will activate actuator into timing mode. LED flashes 2x in each 1s interval. Upon releasing the button, the delayed return time starts counting
  4. After the desired time has elapsed (range of 2s…60min), the timing mode ends by pressing the button on the RF transmitter, to which the delayed return function is assigned. This stores the set time interval into the actuator memory.
  5. Press of programming button on receiver RFSAI-61B shorter then 1 second will fi nish programming mode. The LED lights up according to the pre-set memory function.

Programming with RF control units

  • The address listed on the front of the actuator is used for programming and controlling actuators by RF control units.

Delete actuator

Deleting one position of the transmitter

  • By pressing the programming button on the actuator for 5 seconds, deletion of one transmitter activates. LED flashs 4x in each 1s interval.
  • Pressing the required button on the transmitter deletes it from the actuator’s memory.
  • To confirm deletion, the LED will confirm with a flash long and the component returns to the operating mode. The memory status is not indicated.
  • Deletion does not affect the pre-set memory function.

Deleting the entire memory

  • By pressing the programming button on the actuator for 8 seconds, deletion occurs of the actuator’s entire memory. LED flashs 4x in each 1s interval.
  • The actuator goes into the programming mode, the LED flashes in 0.5s intervals (max. 4 min.).
  • You can return to the operating mode by pressing the Prog button for less than 1s. The LED lights up according to the pre-set memory function and the component returns to the operating mode.
  • Deletion does not aff ect the pre-set memory function.
Selecting the memory function
  1. Press of programming button on receiver RFSAI-61B for 1 second will activate receiver RFSAI-61B into programming mode. LED is flashing in 1s interval.
  2. Pressing the programming button on the RFSAI-61B receiver for less than 1 second will fi nish the programming mode, this will reverse the memory function. The LED lights up according to the current pre-set memory function. The set memory function is saved. Every other change is made in the same way.

Memory function on

  • For functions 1-4, these are used to store the last state of the relay output before the supply voltage drops, the change of state of the output to the memory is recorded 15 seconds after the change.
  • For functions 5-6, the target state of the relay is immediately entered into the memory after the delay, after re-connecting the power, the relay is set to the target state.

Memory function off

  • When the power supply is reconnected, the relay remains off.

Technical parameters

Warning: Control button input is at the supply voltage potential.

Attention

  • When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.
  • Between the individual commands must be an interval of at least 1s.

Warning

The instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Installation and connection can be carried out only by a person with adequate professional qualifi cation upon understanding this instruction manual and functions of the device, and while observing all valid regulations. Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regulations, norms, directives and professional, and export regulations for working with electrical devices. Do not touch parts of the device that are energized life threat. Due to the transmissivity of RF signal, observe correct location of RF components in a building where the installation is taking place. RF Control is designated only for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. They must not be installed into metal switchboards and into plastic switchboards with metal door.

  • transmissivity of RF signal is then impossible. RF Control is not recommended for pulleys etc.
  • radiofrequency signal can be shielded by an obstruction, interfered, battery of the transceiver can get flat etc. and thus disable remote control.

Contact