inELS RFJA-32B-SL Switch Unit for Shutters Instruction Manual

June 3, 2024
inELS

inELS RFJA-32B-SL Switch Unit for Shutters Instruction Manual
inELS RFJA-32B-SL Switch Unit for Shutters

Warning

  • Newly produced drivers work in the RFIO2 data protocol mode. These drivers are loaded in the actuators in a different way than before. Among other things, it eliminates the risk of inadvertently loading another randomly occurring controller within range.
  • Drivers can still be switched to so-called compatibility mode, and loaded in a simpler (older way)
  • The mode in which the controller is located is indicated after inserting the battery and after 5 seconds have passed, at which the LED is lit by subsequent different intervals of flashing of the LED.

RFIO2 mode

Double flash (flash, flash, gap, flash, flash)

Compatibility mode

Flash fast (flash, flash, flash, flash, flash)

  • If you do not want to change the function of the controller, you must not press any buttons during this time.
  • If we need to change the operating mode of the controller, after inserting the battery, when the LED is permanently lit, we press at the same time:
  • button 1 and 3 on RF KEY-40/60
  • button 1 and 2 on RFWB-20/40
  • button 1 and 2 on RFGB-20/40
  • button 1 and 2 on RF KEY

you hold the buttons until the LED starts to signal the changed mode (double fl ash or fast fl ash).
After that, the buttons must be released. The selected mode of the function is stored in memory and after replacing the battery, the controller continues to operate in the same mode.

NOTE: after each removal of the battery, we press one of the buttons several times to discharge the device and reinsert the battery.

UPDATE THE CONTROLLER ACTUATORS IN RFIO2
MODE

If the controller is used in RFIO2 mode, then to update the controller actuators, it is necessary to switch not only the actuator to the update mode (according to the instructions for the actuator), but also the controller in the following way: You remove the battery from the controller, press some of the buttons several times to discharge the device, and reinsert the battery. At the moment when the LED lights up, you press the 1 button and hold it down until the controller starts signaling the updating mode with a short fl ashing of the LED. Then you release the button and the controller now works in RFIO2 update mode. To end the update mode, you remove the battery, press one of the buttons several times, and then reinsert the battery. Now you do not press any button and the controller starts again in RFIO2 operating mode.

UPDATE THE CONTROLLER ACTUATORS IN RFIO2  MODE

Characteristics

  • The switching unit for blinds has 2 output channels used to control garage doors, gates, blinds, awnings, etc.
  • It can be combined with Control or System units iNELS RF Control.
  • The BOX design lets you mount it right in an installation box, a ceiling or motor drive cover.
  • RFJA-32B/230V (120V): connection of switched load 2x 8 A (2x 2 000 W), with the ability to connect existing buttons.
  • Short presses of the controller enable tilting of lamellas, and a long press enables you to draw the blinds up or down to the end position.
  • Each of the units may be controlled by up to 25 channels (1 channel represents one assigned controller).
  • The programming button on the unit is also used for manual control of the output.
  • For components it is possible to set the repeater function via the RFAF / USB service device.
  • Range up to 200 m (in open space), if the signal is insuffi cient between the controller and unit, use the signal repeater RFRP-20 or protocol component RFIO2 that support this feature.
  • Communication frequency with bidirectional protocol iNELS RF Control2 (RFIO2).

Assembly

  • mounting into a non

  • flush mounting

  • ceiling mounted

Connection

Connection Induction

Radio frequency signal penetration through various construction material

Radio frequency signal penetration

For more information, see “Installation manual iNELS RF Control”: http://www.elkoep.com/catalogs-and-brochures

Indication, manual control

  1. LED / button PROG
  2. Addresses for individual relays (channels)
  3. Terminal block-connection for external button
  4. Terminal block-connecting the neutral conductor
  5. Terminal block- load connection
  6. Terminal block for connecting the phase conductor
  • LED STATUS – indication of the device status.
  • Manual control is performed by pressing the PROG button.
  • Programming is performed by pressing the PROG button for more than 1s.
  • Terminal block for connection of buttons. S – direction button up S – button down.
    In the programming and operating mode, the LED on the component lights up at the same time each time the button is pressed – this indicates the incoming command.

Functions and programming with RF transmitters

Function description

  • Shooting fins, short travel.

  • Blinds starts / descend to the end position.

Programming

  1. Repeatedly press of programming button on actuator RFJA for no longer then 1 second will roll up shutters into final upper position.

  2. Press of programming button on actuator RFJA for 1 second will activate actuator RFJA into programming mode. LED is flashing in 1s interval.

  3. Select and press one button on wireless switch, to this button will be assigned Function 1. Second control position “down”, will be assigned automatically (on the same half of wireless switch).

  4. Press of programming button longer then 5 seconds, will activate actuator into timing mode. LED flashs 2x in each 1s interval.

  5. Press of the button on wireless switch with assigned function for shutters down will roll the shutters down. Release the press of this button 2 seconds after the shutter is stopped by lower final switch.
    Programming Induction

  6. Press of the button on wireless switch with assigned function for shutters up will roll the shutters up. Release the press of this button 2 seconds after the shutter is stopped by upper final switch. Duration of rolling up and down is than saved into memory of reciever.
    Programming Induction

  7. Press of programming button on receiver RFJA shorter then 1 second will finish programming mode (LED switches off ).

Delete actuator

Deleting one position of the transmitter

By pressing the programming button on the actuator for 5 seconds, deletion of one transmitter activates. LED fl ashs 4x in each 1s interval.
Pressing the required button on the transmitter deletes it from the actuator’s memory.
The LED goes out and the actuator returns to operating mode.

Deleting the entire memory

By pressing the programming button on the actuator for 8 seconds, deletion occurs of the actuator’s entire memory. LED flashs 4x in each 1s interval.
The actuator goes into the programming mode, the LED fl ashes in 0.5s intervals (max. 4 min.).
You can return to the operating mode by pressing the Prog button for less than 1s.

Technical parameters

Supply voltage: 230 V AC
Supply voltage frequency: 50-60 Hz
Apparent power: 7 VA / cos φ = 0.1
Dissipated power: 0.7 W
Supply voltage tolerance: +10%; -15%

Output

Contacs:| 2x switching / przełączany (AgSnO2)
Rated current:| 8 A / AC1
Switching power:| 2000 VA / AC1
Peak current:| 10 A /
Switching voltage:| 250 V AC1
Mechanical service life:| 1×107
Electrical service life (AC1):| 1×105

Control

Wirelessly:| each of the output up to 25 channels (buttons)
Communication protocol:| RFIO2
Frequency:| 866–922 MHz
Function repeater:| yes
Manual control:| button
External button:| max.100 m
Range:| 200 m

Other data

Operating temperature:| -15…+ 50 °C
Operating position:| any
Mounting:| Free at lead-in wires
Protection:| IP30
Over voltage category:| III.
Contamination degree:| 2
Cross-section of connecting wires:| 3x 0.2, 1x 1.5 mm2
Dimension:| 43 x 44 x 22 mm
Weight:| 45 g
Related standards:| EN 50491, EN 63044, EN 300220, EN 301 489

Attention:

When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units.
Between the individual commands must be an interval of at least 1s.

Warning

Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Installation and connection can be carried out only by a person with adequate professional qualification upon understanding this instruction manual and functions of the device, and while observing all valid regulations. Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regulations, norms, directives and professional, and export regulations for working with electrical devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe correct location of RF components in a building where the installation is taking place. RF Control is designated only for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is then impossible.
RF Control is not recommended for pulleys etc. – radio frequency signal can be shielded by an obstruction, interfered, battery of the transceiver can get fl at etc. and thus disable remote control.

Support

ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech Republic | e-mail: elko@elkoep.com | Support: +420 778 427 366
ELKO EP Poland, sp. z o. o. | ul. Motelowa 21 | 43-400 Cieszyn | Polska | e-mail: elko@elkoep.pl | GSM: +48 785 431 024
www.elkoep.com / www.elkoep.pl

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

inELS User Manuals

Related Manuals