Laserliner 082425 ThermoControl Air Instruction Manual

June 9, 2024
Laserliner

Laserliner 082425 ThermoControl Air

Laserliner-082425-ThermoControl-Air

Function / Application

ThermoControl Air is a professional thermometer for grilling, cooking and roasting that determines the core temperature of various types of meat, poultry and fish. Preset core temperatures, individual temperatures, or a specific time can be set using
the linked app.
Note: Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and if the laser device is passed on, this document must be passed on with it.

General safety instructions

  • The device must only be used in accordance with its intended-purpose and within the scope of the specifications.
  • Not suitable for explosive environments or medical diagnoses.
  • The measuring tools and accessories are not toys. Keep out of reach of children.
  • Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
  • Do not expose the device to mechanical stress, extreme tem-peratures, moisture or significant vibration.
  • The device must no longer be used if one or more of its functions fail or the battery charge is weak.
  • Use only original accessories. Using other accessories invalidates the warranty.
  • With the measuring probe in the charger, if the LED lights up when the button for checking the charge level is pressed, the charging process is complete.
  • Allow the probe to cool slowly before cleaning and storing. Shock from high temperature differential (e.g. from cold water) may damage the probe.
  • Never use the probe at temperatures > 85°C.
  • Use the probe dry and not too close to the heat source.
  • Clean the sensor thoroughly before and after each use.
  • Not suitable for dishwashers.
  • Do not use the measuring probe with an external voltage.
  • Danger of injury! The measuring point is sharp and can lead to injury.
  • Store the probe in the charging unit when not in use.
    Note: The measuring point can get very hot. Wear protective or barbecue gloves when picking the probe up.
    Note: The probe can be washed (IP 66) but may not be immersed!
Safety instructions

Dealing with electromagnetic radiation

  • The measuring device complies with electromagnetic com-patibility regulations and limits in accordance with the EMC Directive 2014/30/EU which is covered by the Radio Equipment Directive 2014/53/EU.
  • Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers –may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
  • The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.

Dealing with RF radiation

  • The measuring device is equipped with a wireless interface.
  • The measuring device complies with electromagnetic compati-bility and wireless radiation regulations and limits in accordance with the RED 2014/53/EU.
  • Umarex GmbH & CO. KG hereby declares that the ThermoControl Air radio equipment meets the requirements and other specifi-cations of the European Radio Equipment Directive 2014/53/EU (RED). The EU Declaration of Conformity can be found in its entirety at the following address:
    http://laserliner.com/info?an=AJI

Inserting battery

Open the battery compartment and insert battery according to the symbols. Be sure to pay attention to polarity.

Charger

Laserliner-082425-ThermoControl-Air-3

  1. Button for checking the battery charge level (charger and measuring probe)

  2. Integrated magnet holder (rear)

  3. LED charge level display (1)

  4. Battery compartment (rear)
    Measuring probe

  5. Point for measuring the contact temperature

  6. Insert marking / charging contact

  7. Sensor for measuring the environmental tempe-rature / charging contact

Charging the battery (measuring probe)Laserliner-082425-ThermoControl-
Air-4

Charge level display Battery (charger)

  • LED (3) illuminated: battery is charged
  • LED (3) not illuminated: replace batteryLaserliner-082425-ThermoControl-Air-5

Battery (measuring probe)

  • LED (3) flashes: battery charging
  • LED (3) illuminated: battery is fully chargedLaserliner-082425-ThermoControl-Air-6
Insert probe in item to be measured

Laserliner-082425-ThermoControl-Air-7

Note: To avoid damage, the probe must always be inserted into the item to be measured up to the marking and the core temperature may not exceed a temperature of 85°C.

Data transfer
  • The device features a Bluetooth® function that enables wireless data transfer to mobile devices with a Bluetooth® interface (such as a smartphone or tablet).
  • The system prerequisites for a Bluetooth®* connection are specified at http://laserliner.com/info?an=ble
  • The device can set up a Bluetooth®* connection with Bluetooth 4.0 compatible devices.
  • The range is set to a maximum distance of 10 m from the terminal device and greatly depends on the ambient conditions such as the thickness and composition of walls, sources of interference as well as the transmit / receive properties of the terminal device.

Application (app)

An app is required to use the Bluetooth®* function. You can download the app from the corresponding stores for the specific type of terminal device:Laserliner-082425-ThermoControl-Air-8

Note: Make sure that the Bluetooth® interface of the mobile device is activated. Bluetooth® is always activated once the probe is removed from the charger. A mobile device can connect to the removed probe via an app.

Once the app is open, the connection assistant provides information on the status of the Bluetooth®* connection to the measuring device.
If the app identifies more than one device, these can be individually selected using the connection assistant.
Note: The Bluetooth® word mark and the logo are registered trademarks of Bluetooth SIG Inc.Laserliner-082425-ThermoControl-
Air-10

Danger – powerful magnetic fields
Powerful magnetic fields can adversely affect persons with active medical implants (e.g. pacemaker) as well as electromechanical devices (e.g. magnetic cards, mechanical clocks, precision mechanics, hard disks).
With regard to the effect of powerful magnetic fields on persons, the applicable national stipulations and regulations must be complied with such as BGV B11 §14 „electromagnetic fields“ (occupational health and safety – electromagnetic fields) in the Federal Republicof Germany.
To avoid interference/disruption, always keep the implant or device a safe distance of at least 30 cm away from the magnet.

Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.

ThermoControl Air

Technical Data

Measured variable| Contact temperature Ambient temperature
Contact temperature measuring range| 0°C … 85°C
Contact temperature accuracy| ± 1°C
Ambient temperature measurement range| 0°C … 300°C
Degree of protection| IP 66
Power supply| 1 x 1.5V LR6 (AA)
Operating time| approx. 4 hours

Operating conditions

| Probe: 0°C … 85°C, Charger: -10°C … 50°C, max. humidity 85% rH,

no condensation, max. working altitude 2000 m above sea

Storage conditions| -10°C … 60°C, max. humidity 85% rH, no condensation

Radio module operating data

| Bluetooth LE 4.x interface; Frequency band: ISM band 2400–2483.5 MHz, 40 channels; Transmission power: max. 10 mW; Bandwidth: 2 MHz; Bit rate:

1 Mbit/s; Modulation: GFSK/FHSS

Dimensions (W x H x D)| 168 x 24 x 40 mm
Probe| 90 mm, ø 5,9 mm
Weight| 80 g (incl. battery)

Subject to technical changes without notice. 20W05

EU directives and disposal

This device complies with all necessary standards for the free movement of goods within the EU.
This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment. Further safety and supplementary notices at: http://laserliner.com/info?an=AJILaserliner-082425-ThermoControl-
Air-11

SERVICE

Umarex GmbH & Co. KG Laserliner
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: +49 2932 638-333
info@laserliner.com

Umarex GmbH & Co. KG Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300
Fax: +49 2932 638-333
www.laserliner.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Laserliner User Manuals

Related Manuals