Akuvox E16 Face Recognition Door Phone Installation Guide

June 9, 2024
Akuvox

Akuvox-E16-Face-Recognition-Door-Phone-LOGO

Akuvox E16 Face Recognition Door Phone

Unpacking
Please make sure the package contains the following items:

Universal Accessories

Akuvox-E16-Face-Recognition-Door-Phone-01

Digital Temperature Detector Accessories (Optional)

Akuvox-E16-Face-Recognition-Door-Phone-02

Product Overview

Akuvox-E16-Face-Recognition-Door-Phone-03

Installation Environment

Please do not place device under direct sunlight, it will bring bad effect or be broken with high temperature.
If installing the device indoors, please keep device at least 2 meters away from light, and at least 3 meters away from window and door.Akuvox-E16-Face-
Recognition-Door-Phone-04

Attention:
Biometric recognition product may not be considered 100% to fit in any identification application. For higher security purpose or scenario, please set up access authentication combination.

Installation

1. Step: Wall-mounting Bracket Installation

With embedded one-gang junction box (86×86 mm or 2×3 inches in size) in the wall

With 86×86 mm embedded junction box in the wall

Akuvox-E16-Face-Recognition-Door-Phone-05

  • Fix the wall-mounting bracket on the embedded box with two M4x30 crosshead screws.

  • Mark the two positioning holes of the wall-mounting bracket on the wall.
    Note: the positioning holes should be marked in the center of the holes.

  • Remove the two M4x30 crosshead screws and take off the wall-mounting bracket.
    Akuvox-E16-Face-Recognition-Door-Phone-06

  • Fix the wall-mounting bracket with two M4x30 crosshead screws and two ST 4×20 crosshead screws.

  • Insert two plastic wall anchors into the two drilled holes.

  • Use a hand drill with 6 mm diameter bit to make two positioning holes with 25 mm in depth in the marked positions.

With 2×3 inches embedded single-gang box in the Wall

Akuvox-E16-Face-Recognition-Door-Phone-07

  • Fix the wall-mounting bracket on the single-gang junction box with the two M4x30 crosshead screws.
  • Finish the bracket Installation.
Without embedded gang box in the wall

Akuvox-E16-Face-Recognition-Door-Phone-08

  • According to the position of the cable, put the wall-mounting bracket closely on to the wall and mark the four positioning holes, while making sure that relative positions between  wall-mounting bracket and wire hole are correct.
    Note: The positioning holes should be marked in the center of the holes.

  • Take off the wall-mounting and drill the four marked positioning holes and the wire holes using 6 mm hand drills.
    Akuvox-E16-Face-Recognition-Door-Phone-09

  • Fix the wall-mounting bracket with four ST 4×20 crosshead screws.

  • Insert four plastic wall anchors into the holes.

Step 2: Device Installation

Device Installation without Digital Forehead or Wrist Temperature DetectorAkuvox-E16-Face-Recognition-Door-Phone-10

  • Take out the device along with the wiring cover, sealing pressing plate, rubber plug and corresponding screws.

  • Lead the wires from the wall-mounting bracket and the detector through the square hole on the wiring cover, connecting them to the corresponding interface of the main board. Select a suitable size rubber plug to push all the cables into the wiring cover. Fix sealing pressing plate to the wiring cover with two M2.5×6 crosshead Screws.
    Akuvox-E16-Face-Recognition-Door-Phone-11

  • And please remove the protective film. Installation is completed.

  • Hang the device on to the square hanger on the wall-mounting bracket, pull down the device to make it fall completely on to the square hanger on the wall-mounting bracket, then use the torx wrench attached to tighten the device with the M3x6 torx head screw.

  • Fasten the wiring cover with four M3x6 torx head screws using the torx wrench attached.

Device Installation with Digital Forehead Temperature Detector (Optional)

Akuvox-E16-Face-Recognition-Door-Phone-12

  • Take out device and the digital forehead temperature detector and then take out wiring cover, sealing pressing plate, rubber plug and corresponding screws.
  • Fasten the detector on to the nuts on the device’s wiring cover with two M3Xl0.5 hex socket screws using the alien wrench attached, and lead the wires from the wall-mounting bracket and the detector through the square hole on the wiring cover, connecting them to the corresponding interface of the main board. And then select a suitable size rubber plug to push all the cables into the wiring cover. Fix sealing pressing plate to the wiring cover with two M2.5×6 crosshead screws.Akuvox-E16-Face-Recognition-Door-Phone-13
  • And please remove the protective film. Installation is completed.
  • Hang the device on to the square hanger on the wall-mounting bracket, pull down the device to make it fall completely on to the square hanger on the wall-mounting bracket, then use the torx wrench attached with to tighten the device with the M3x6 torx head screw.
  • Fasten the wiring cover with four M3X6 torx head screws using the torx wrench attached.

Device Installation with Digital Wrist Temperature Detector (Optional)

Akuvox-E16-Face-Recognition-Door-Phone-14

  • Fix the two holes of the detector onto the installation pins on the wall-bracket either on the left or right according to your preference.
  • Tighten the detector on to the inner threaded bolt with two M3x4 crosshead screw using the alien wrench attached in the same way on both side.
  • Take out the device along with the wiring cover, sealing pressing plate, rubber plug and corresponding screws.Akuvox-E16-Face-Recognition-Door-Phone-15
  • Fasten the wiring cover with four M3x6 torx screws using the torx Wrench attached.
  • Lead the wires from the wall-mounting bracket and the detector through the square hole on the wiring cover, connecting them to the corresponding interface of the main board. And then select a suitable size rubber plug to push all the cables into the wiring cover. Fix sealing pressing plate to the wiring cover with two M2.Sx6 crosshead screws.Akuvox-E16-Face-Recognition-Door-Phone-16
  • Hang the device on to the square hanger on the wall-mounting bracket, pull down the device to make it fall completely on to the square hanger on the wall-mounting bracket, then use the torx wrench attached to tighten the device with the M3x6 torx head
  • And please remove the protective film. Installation is completed.

Device Wiring

Akuvox-E16-Face-Recognition-Door-Phone-17

Warning
When you connect a device containing a coil, such as a relay or an electromagnetic lock, it is necessary to protect the intercom against voltage peak while switching off the induction load. For this way of protection we recommend a diode 1A/200 V (included in the accessories) connected antiparallel to the device.Akuvox-E16-Face-Recognition-Door-
Phone-18

Wire Length & AWG Table
Please follow the properly measured wire gauge/length to install device:

| 20AWG| 22AWG| 24AWG| 26AWG
---|---|---|---|---
12V IAA dater| ,;;2om| ,;;1om| I| I

Application Network Topology

Akuvox-E16-Face-Recognition-Door-Phone-19

Configuration

  1. IP address Checking: Long press any where on the initial screen for approximately five seconds to go to project PIN screen where you enter the default PIN “ad min” and press Confirm tab to go to Setting screen where you press Info icon to check for the device IP address. ( for E16 series door phone only)
  2. Account Registration: On the web interface, go to the path Account> Basic page to register and fill in the account information. (please refer to user manual for more information)
  3. DTMF code configuration: On the web interface, go the path: Access Control>relay to set up the DTM F code in the corresponding area.

Operation

  • Make a call:
    Press Dial icon into the dial interface, and enter the IP or SIP number and press Dial key to make a call ( for E16 series door phone only).

  • Receive a call:
    E16 supports Auto Answer by default. Incoming call from indoor device will be answered automatically.

  • Unlock by DTMF:
    During the call, press the corresponding DTMF code from the answer unit to unlock E16 remotely.

  • Unlock by RF Card:
    Place the predefined RF card in the card reader area to open the door.

Notice Information
Akuvox El6/A0S firmware contains third-party open source software under the terms of the GNU General Public License(GPL). Akuvox is committed to meeting the requirements of the GNU General Public License (GPL) and will make all required source code available.
The source code of software under the terms of GNU GPL can be downloaded on line: http://www.akuvox.com/gpl.
Information contained in this document is believed to be accurate and reliable at the time of printing. This document is subject to change without notice, any update to this document can be viewed on Akuvox’ s website: http://www.akuvox.com © Copyright 2022 Akuvox Ltd. All rights reserved.

AKUVOX (XIAMEN) NETWORKS CO., LTD.
Add.: 10/F, NO.56 GUAN RI ROAD, SOFTWARE PARK 11, XIAMEN 361009, CHINA www.akuvox.com

Akuvox-E16-Face-Recognition-Door-Phone-21

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals