Akuvox NS-2 IP Wireless Network Switch User Guide
- June 4, 2024
- Akuvox
Table of Contents
Akuvox NS-2 IP Wireless Network Switch
Unpacking
Before you begin using the device, please check the version you got and ensure
that the following items are included in the shipped box:
Device Installation
Device Installation
Press down the NS-2 on the front, push the two clasps upwards, and make the
buckles snap into the guide rail, and then fix it on to the guide rail.
Power Adapter Installation
Place the power adapter on the corresponding position of the guide rail as shown in the figure above, and fasten the plastic buckle on the guide rail to fix the power adapter.
Note: Power adapter was not provided in the shipped box, please purchase
it separately if you need it.
Note: The power adapter is 48V/1.25A DC or 24V/2A DC. Please refer to
Device Wiring section for more connection details.
Device Wiring
Note:
- Each NS-2 supports a maximum of 6 loads, otherwise, it may not be [ powered on or power off duringuse.
- The PLC-S lead wire of NS-2 must be kept at least 5 cm away from the PLC-1 ~PLC-6 lead wire, otherwise the signal will loop back and the network cannot be used.
Application Network Topology
Application Network Topology
Adapter Voltage
| Cable Model| Farthest Distance| Adapter Voltage| Cable Model|
Farthest Distance
---|---|---|---|---|---
48V
| 24awg| 300m|
24V
| 24awg|
150m
20awg| 300m| 20awg|
250m
18awg
| 300m| 18awg|
300m
Topology-2:devices are series connection with NS-2.
Adapter Voltage| **Cable Model| ****Farthest Distance|
Adapter Voltage| Cable Model| Farthest Distance
---|---|---|---|---|---
48V| 24awg| 1000m /6 El 150m /4 El 2oom /3 El| 24V**| 24awg| 50m/3El
150m/1El
20awg| 250m /6 El
300m /5 El| 20awg| 100m/3El
150m/2El
250m/1El
18awg| 300m/6El| 18awg| 100m/6El
150m/4El 2oom/3El 300m/2El
Note: When using different cable, the maximum number of devices can connect to NS-2 under the different maximum distances which can refer to the above table. For example, when using a 24awg cable, ifthe farthest distance is 100m, the maximum number of devices connect to NS-2 is 6.
Notice Information
Information contained in this document is believed to be accurate and reliable
at the time of printing. This document is subject to change without notice,
any update to this document can be viewed on Akuvox’ s website:
http://www.akuvox.com © Copyright 2022 Akuvox Ltd. All rights reserved.
AKUVOX (XIAMEN) NETWORKS CO., LTD.
ADD: 10/F, NO.56 GUAN RI ROAD, SOFTWARE PARK II, XIAMEN 361009, CHINA
www.akuvox.com
Read User Manual Online (PDF format)