Technogamma S200 UPS Inverter Charger User Manual

June 16, 2024
Technogamma

Technogamma-logo

Technogamma S200 UPS Inverter Charger

SineaUPS
Models 5100a, 5100a+, 5100 and 5200

Introduction

  • SineUPS is an uninterruptible power supply, guaranteeing constant powering to the electric loads connected. In case of mains failure (power cut or instability) SineUPS generates pure sine wave and can work continuously until the battery runs out. The output voltage has the same form as the mains voltage meaning that the connected loads will work just as efficiently as being powered from the mains network.
  • When the device is powered by regular mains voltage, it keeps the battery fully charged so it can provide its maximum capacity when needed.

Installation

Warning!
SineUPS works at high voltage and requires special attention when its being connected!
The device is designed for home use only! Please make sure there is enough space around it to vent properly1 do not install it in a place exceeding the operating temperature and humidity!

Mounting

The device can be mounted on a horizontal surface or vertically on a wall. In order to mount it vertically, install 4 screws on the wall (3.5 x 35 mm), so the unit can be hanged as depicted on the drawing below.

Connection

Technogamma-S200-UPS-Inverter-Charger-01 \(3\)

  1. Connect the load’s power plug to the OUTPUT socket of the UPS.
  2. For models 5100 and 5200 an external battery has to be connected (models 5100a and 5100a+ have integrated battery, so skip this step, as Sl00a+ has an option for connecting external battery so the step is not mandatory). Connect the battery to the BATTERY terminal, paying attention to the polarity- the+ cable goes to the+ terminal of the battery. Depending on the particular type of installed battery, there is possibility that some harmful gases can be released and in that case it is recommended to install the device in a proper location.
  3. Verify that the load and battery are properly connected. Plug the power plug of the UPS (INPUT terminal) to mains socket. If mains is present, the device will start charging the battery. If in the electrical installation a common neutral is used instead of protective earth (PE), it is recommended to cut off the plug and power the device using hard wiring -brown wire to phase and blue to neutral.
  4. Turn on the device to power the load connected by pressing the power on button (see next chapter Operation).

Operation

Technogamma-S200-UPS-Inverter-Charger-01 \(5\) Press and hold the power button ( ) for 0.5 sec to power the device and load connected. The button LED lights on and a beeping sound is made.

Stable mains

  • Whenever stable mains is present, the device charges the battery and displays the current charge on the panel.
  • If the device is turned on and the mains is off or unstable, it automatically switches to battery powered mode.
  • If the mains is not available, the indicator goes off, if the mains voltage is not within the specified limits the indicator blinks.

Battery power

  • Switching to battery powered mode a continuous sound is made in the time of transition and then a short one every 30 sec.
  • The time to operate on battery power depends on the capacity, charge and condition of the connected battery, as well as the power of the load connected. When the battery charge goes below 10%, the device beeps every 2 sec until the battery voltage goes below 10.2 V, then the device automatically shuts down. When the mains is restored, the device automatically turns on and starts charging the battery.
  • In case of connecting a load that is more powerful than the device rated output power or short-circuit of the output, the LED lights up and the power to the load is cut off.
  • The UPS will attempt 10 retries in 10 sec to restore the power to the load and if the overload condition is removed will go back to normal battery power operation.

Troubleshooting

Problem Solution

Problem
The device is connected to mains, but pressing the button ( ) does not turn it on.| The device does not function without a connected battery!

  • If you are using a car battery, please check the mounted terminals – some of them are painted on the inner side and do not ensure proper electrical contact to the battery contacts.
  • The battery should be in good condition. If the voltage of the connected battery is under 10.SV, then the device will not turn on /low voltage battery protection/.

The LED does not indicate the presence of mains.| Check the device connections and mains voltage. Check the device fuse and replace it if necessary.
The device makes long beep and turns itself of during power up| Device internal error. Please contact the authorized service center.
The LED is on and beeps every 30 sec.| Normal work in battery powered mode, the device is turned on and the mains is missing.
Inadequate work time in battery mode.| Check that the battery is fully charged (at least 10 hours).

With time the battery capacity decreases. Contact the authorized service for internal battery replacement (model 5100a) or replace the external battery with a new one (models 5100 and 5200).

Technical parameters

Technogamma-S200-UPS-Inverter-Charger-10 Technogamma-S200-UPS-Inverter-Charger-11

External battery is not part of the product .