anslut 018969 LED Industrial Luminaire Instruction Manual

June 9, 2024
anslut

anslut 018969 LED Industrial Luminaire

Jula AB reserves the right to make changes to the product. Jula AB claims copyright on this documentation. It is not allowed to modify or alter this documentation in any way and the manual shall be printed and used as it is in relation to the product. For the latest version of operating instructions, refer to the Jula website.

WWW.JULA.COM
© JULA AB 2022-12-12
JULA AB
BOX 363, 532 24 SKARA, SWEDEN

SAFETY INSTRUCTIONS

  • Intended for indoor and outdoor use.
  • The electrical installation must comply with local regulations. Consult an authorised electrician if in doubt.
  • Always follow the electrical specifications on the product labelling.
  • Always disconnect the power supply before installation, connection and service.
  • Do not use the product if the glass cover is damaged.
  • The light must be connected to an earthed power supply on installation.
  • If the power cord to this light is damaged it must only the replaced by the manufacturer or a service technician, or other qualified person, to ensure safe use.
  • Before drilling in walls, ceilings or floors, check that there are no concealed electrical cables or piping.
  • The product must only be installed by qualified personnel.
  • Use a suitable hanger for the installation.
  • The hook must be able to support at least 10 kg (four times the weight of the product). The manufacturer cannot be held responsible for any damage caused by incorrect installation.
  • The light source must be replaced by an authorized service representative or other qualified personnel.

ELECTRICAL SAFETY

New installations and extensions to existing systems should always be carried out by an authorised electrician. If you have the necessary experience and knowledge (otherwise contact an electrician), you can replace power switches and wall sockets, fit plugs, extension cords and light sockets. Incorrect installation can result in fatal injury and the risk of fire.

Symbols

Read the instructions.
The product is not dimmable.
Approved in accordance with the relevant directives.
Recycle end-of-life product in accordance with local regulations.

TECHNICAL DATA

  • Rated voltage
    • 230 V ~ 50 Hz
  • Output
    • 100 W
  • Luminous flux
    • 16000 lm
  • Energy class
    • C
  • Colour temperature
    • 4000 K
  • Life span
    • 50000 h
  • Dimmable
    • No
  • Protection rating
    • IP65
  • Power factor
    • 0.90
  • Weight
    • 2.51 kg

INSTALLATION

NOTE

  • Always disconnect the power supply before installation.
  • Cables must not touch the product because the high temperature of the light can damage them, and cause a fire risk.
    1. Disconnect the mains voltage.
    2. Screw in the eye screw and tighten. FIG. 1
    3. Connect the wires:
    • Black: Live wire.
    • White: Neutral wire.
    • Green-yellow: Earth.
    1. Check that the grommet is tight.
    2. Fasten a hook to the ceiling.
    3. Hang up the light on the hook. Secure the opening of the hook.

MAINTENANCE

  1. Switch off the power supply.
  2. Allow the light to cool.
  3. Wipe the light with a dry or slightly damp cloth.
  4. Wait until the light is completely dry before switching the power supply on again.

NOTE:

Do not use detergent, alcohol, solvent or the equivalent to clean.

PRODUCT INFORMATION SHEET

Supplier’s name or trademark: ANSLUT
Supplier’s address (a): Jula Ascia Co Ltd, Julagatan, 2, 53237 Skara, SE
Model identifier: 018969
Type of light source:
Lighting technology used: LED

Light source connected to mains supply or light source not connected to mains supply:| ****

MLS

| ****

Connected light source (CLS):

| ****

no

Colour-tuneable light source:| no| Envelope:| –
High luminance light source:| no|  |
Anti-glare shield:| no| Dimmable:| no
Product parameters
Parameter| Value| Parameter| Value
General product parameters:
Energy consumption in on-mode (kWh/1000 h)| 100| Energy efficiency class| C
Useful luminous flux (Φuse), indicating if it refers to the flux in a sphere (360˚), in a wide cone (120˚) or in a narrow cone (90˚).| ****


16 000 in sphere (360°)

| Correlated colour temperature, rounded to the nearest 100 K, or the range of correlated colour temperatures, rounded to the nearest 100 K, that can be set.| ****


4 000

On-mode power (Pon), expressed in W.| ****

100,0

| Standby power (Psb), expressed in W and rounded to the second decimal.|


0,00

Networked standby power (Pnet) for CLS, expressed in W and rounded to the second decimal.| ****

| Colour rendering index, rounded to the nearest integer, or the range of CRI- values that can be set.| ****

80

Outer dimensions without separate control gear, lighting control parts and non-lighting control parts, if any (millimetre).| Height| 165| ****

Spectral power distribution in the range 250 nm to 800 nm, at full-load.

| ****

See image in last page

Width| 240
Depth| 240
Claim of equivalent power (c)| –| If yes, equivalent power (W)| –
 |  | ****

Chromaticity coordinates (x and y)

| 0,378

0,376

Parameters for LED and OLED light sources:
R9 colour rendering index value| 13| Survival factor| 0,90
The lumen maintenance factor| 0,96|  |
Parameters for LED and OLED mains light sources:
Displacement factor (cos φ1)| 1,00| Colour consistency in mcadam ellipses| 2
Claims that an LED light source replaces a fluorescent light source without integrated ballast of a particular wattage.| ****

-(b)

| ****

If yes then replacement claim (W)

| ****

Flicker metric (Pst LM)| 0,0| Stroboscopic effect metric (SVM)| 0,0

SPECTRUM

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals