anslut 018968 Industrial Luminaire LED Instruction Manual

June 3, 2024
anslut

anslut logo

anslut 018968 Industrial Luminaire LED

anslut 018968 Industrial Luminaire LED

SAFETY INSTRUCTIONS

Read these instructions carefully before installation and save them for future reference.

  • The light source should only be replaced by an authorised service centre or other qualified personnel.
  • The power cord cannot be replaced. The whole product must be replaced if the cord is damaged.
  • The electrical installation must comply with local regulations. Consult an authorised electrician if in doubt.
  • Always follow the electrical specifications on the product labelling.
  • Always disconnect the power supply before installation, connection and service.
  • Do not use the product if the glass cover is damaged.
  • Never modify the light, this could result in serious material damage/personal injury, and will invalidate the warranty.
  • The light must be connected to an earthed power supply on installation.
  • Before drilling in walls, ceilings or floors, check that there are no concealed electrical cables or piping.

ELECTRICAL SAFETY

New installations and the expansion of existing systems must only be carried out by authorised electrician. Persons with sufficient knowledge can replace switches and power points, fit plugs and bulb sockets. Incorrect installation can result in a risk of fire, electric shock and/or personal injury.

SYMBOLS

 |

Read the instructions.

---|---
 |

Protective earthing

 | Approved in accordance with the relevant directives.
–| Recycle discarded product in accordance with local regulations.

TECHNICAL DATA

  • Voltage: 230 V 50 Hz
  • Output: 200W
  • Energy class: (A – G) C
  • Colour temperature: 4000 K
  • Luminous flux: 320001m
  • Life span: 50000 h
  • Protection rating: IP65
  • Dimmable: No
  • Ambient temperature: -30 to 50° C
  • Cord length: 30 cm
  • Weight: 2,8 kg
  • Size: D 20.8 x 040 cm

INSTALLATION

  • The product can be installed indoors and outdoors.
  • The product can be installed on the ground or a wall as a floodlight, or is installed in a group on a mast over 5 m high.
  • The product is suitable for use in a garage, workshop, or sports centre etc., where lighting must be installed at least 2 metres over the floor. Always hang up the product on a suitable hook.
  • The product has a glass cover of heat resistant and shock-resistant hardened glass. The glass can withstand up to 200°C. Exposure to excessive pressure will shatter the glass.
  • Connect the product wires to the mains and insulate. The connects must comply as a minimum with protection rating IP65.
  • Hang up the product in the required place.
  • The product must be earthed.
  • The electrical installation should be carried out by an authorised electrician in compliance with national regulations. The connecting cable (sold separately) must be approved for outdoor use, with a minimum wire cross-sectional area of 2 x 1.0 mm2

Connect the mains wires to the product terminals as follows.

  1. Connect the live wire (brown to the terminal marked Lon the product.
  2. Connect the earth wire (yellow/green) to the terminal marked E or . · ,· on the product.
  3. Connect the neutral wire (blue) to the terminal marked N.
  4. Check that all connections sit firmly in place and that no loose wires stick outside the terminals. Terminal block sold separately. Consult an authorised electrician if in doubt.
  5. Connect the wires from product junction box to the mains.
    • Connect with clip terminals that comply with the requirements in IEC/EN60998-1, IEC/EN60998-2-2.
    • Rated voltage 450 V. Rated current 16 A. The minimum wire cross­sectional area is 3 x 1.0 mm 2.
    •  Protection rating IP65.
    • Screw on the junction box cover and seal to guarantee the protection rating.

EASY TO INSTALL

  1. Switch off the power supply before installation.
  2. Install the product in accordance with the instructions. The connections must comply with protection rating IP65.
  3. Restore the power when the installation is complete.

Standard cord length 183 cm. Kit for ceiling or suspended installation sold separately. The suspension must withstand 5 times the weight of the product.

PRODUCT INFORMATION SHEET

Supplier’s name or trademark: ANSLUT
Supplier’s address (•): Jula Ascia Co Ltd, Julagatan, 2, 53237 Skara, SE
Model identifier: 018968
Type of light source:
Lighting technology used: LED

Light source cap-type

(or other electric interface):

| 230V AC 50Hz|  |
Light source connected to mains supply or light

source not connected to mains supply:

| MLS| Connected light source (CLS):| [yes/no]
Colour-tuneable light source:| no| Envelope:| no
High luminance light source:| no|  |
Anti-glare shield:| no| Dimmable:| no
Product parameters
Parameter| Value| Parameter| Value
General product parameters :
Energy consumption in on-mode (kWh/1000 h),

rounded up to the nearest integer.

| 200| Energy efficiency class|
Useful luminous fiux (¢=), indicating if it refers to the flux in a sphere (360°), in a wide cone (120°) or in a narrow cone (90°).|

32 000 in

Sphere (360°)

| Correlated colour temperature, rounded to the nearest 100 K, or the range of correlated colour temperatures, rounded to the

nearestlOOK, that can be set.

|

4000

On-mode power (P ), expressed in W.

00

| 200,0| Standby power (P), expressed in Wand

rounded to the second decimal.

| 0,00
Networked standbypower IP,.,) for CLS,

expressed in Wand rounded to the second decimal.

|  | Colour rendering index, rounded to the

nearest integer, or the range of CRl-values that can be set.

|

80

Outer dimensionswithout separate control gear, lighting control parts and non- lighting

control parts, if any (millimetre)

| Height| 765|

Spectral power distribution in the range 250 nm to 800 nm, at full-load.

|

See image in last page

Width| 320
Depth| 320
Claim of equivalent power (a)|  | If yes, equivalent power (WI|
 |  | Chromaticity coordinates (x and y)| 0,381

0,377

Parameters for LED and OLEO light sources:
R9 colour rendering index value| 14| Survival factor| 0,90
The lumen maintenance factor| 0,96|  |
Parameters for LED and OLEO mains light sources:
Displacement factor (cos1)| 0,98| Colour consistency in mcadam ellipses|
Claims that an LED light source replacesa fluorescent light source without integrated ballast of a particular wattage.|

_lb)

|

If yes then replacement claim (WI

|
Flicker metric (Pst LM)| 0,0| Stroboscopic effect metric {SVM)| 0,0