RAB Post Top Series 36W LED HID Cool White Light Bulb Instructions

June 2, 2024
RAB

Top Series 36W LED HID Cool White Light Bulb
Instruction Manual
HID-XX-E26-8XX-BYP/3SP, HID-XX-EX39-8XX-BYP/3SP
HID-XXX-EX39-8XX-BYP-PT, HID-XXX-EX39-8XX-BYP-PT-G2

Post Top Series 36W LED HID Cool White Light Bulb

RAB Post Top Series 36W LED HID Cool White Light Bulb

Our sensor product numbers include MW-S/SMW-S, PIR-S/SPIR-S and DAYLIGHT-S are optional accessories for select PostTop lamps.
The lamps will perform as normal if no sensor is inserted. Please note that RAB lamps can’t operate with other brand sensors.

IMPORTANT

READ CAREFULLY BEFORE INSTALLING LED HID BULBS. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB ED+ID Bulbs must be in accordance with the National Electrical Code and all applicable codes.
Proper grounding is required for safety. THIS PRODUCT MUST BE
INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON AMIL AR WIH  THE CONSTRUCTION AND  OPERATION OF HE PRODUCT AND [HE HAZARDS INVOLVED.

WARNINGS:

  • Main applications include for use in post top, street lights and other suitable light fixtures.
  • Operating temperature: -30C to 60C(-22F to 140F),
  • These LED Lamps require all ballasts, capacitors, and ignitors to be bypassed or removed. Do not operate lamps on existing ballasts.
  • Dimmable with optional control modules.
  • Do not use with standard dimmers. Only use the control provided with or specified by these instructions to control this lamp. This lamp will not operate properly when  connected to a standard (incandescent) dimmer or dimming control.
  • This device is not intended for use with emergency exits.
  • Can be used in enclosed fixtures. DO NOT install SOW 100W 120W these lamps in horizontal applications.
  • Before installation make certain the AC power to the fixture is off.
  • Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and  components.
  • Risk of fire or electric shock. LED Retrofit lamp installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a  qualified electrician.
  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
  • Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead installers should cut existing  lampholder leads away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors.
  • To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
  • Risk of fire or electric shock. Install this kit only in luminaires that have the construction features and dimensions shown in the photographs or drawings and where the  input rating of the retrofit kit does not exceed the input rating of the luminaire.
  • Use only with a portable luminaire that is provided with a shade.
  • Added weight ofthe device may cause instability of a free-standing portable luminaire.
  • THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE  DETERMINED BY AUTHORITIES HAVING JURISDICTION.

LAMP INSTALLATION

  1. Turn off the power before installation Remove old ballast or disconnect from existing lampholder Shown as Figure l Remove and dispose of ballast in correct manner  (North America 100-277VAC)RAB Post Top Series 36W LED HID Cool White Light Bulb - Figure 1

  2. Reconnect directly to the existing mapholder Shown as Figure 2 (North America 100-277VA)
    Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
    INSTRUCTIONS POSTTOP SERIES
    RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-e-hcient LED lighting and controls that make it easy for electricians to install and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com

  3. Install LED replacement amp. Shown as Figure 3. Please make sure the old fitting is correctly grounded Attach retrofit label to luminaire (North America 100-277/A)
    RAB Post Top Series 36W LED HID Cool White Light Bulb - Figure
2Securely fasten the ground to the main body structure. If the wire is damaged in any way please replace (Do not use existing burnt out If needed, the replacement ground  wire must be 10mm in size and insulated from heat

SAFETY CABLE INSTALLATION INSTRUCTION

You must use the safety cable to secure the lamps equal to or over 80W in case of falling down due to old socket

  1. Remove the enclosed safetv cable from the package.
    RAB Post Top Series 36W LED HID Cool White Light Bulb - Figure
3

  2. Attach the safety cable to one end of the lamp.

  3. Attach the other end of the safety cable to the luminaire.

2023RAB LIGHTING Inc
Cranbury, New Jersey 08512U54
HIDPTG2-IN-0123
rablighting.com
Tech Help Line
e-mail
Free Lighting Layouts
Visit our website for product info
Call our experts. 888 722 1000
Answered promptly sales rablighting.com
Answered online or by request

RAB WARRANTY: RAB’s warranty is subject to all terms and conditions found at

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals