pontec PondoSolar 150 Instructions

June 3, 2024
pontec

PondoSolar 150
Instructionspontec PondoSolar fig 5

PondoSolar 150

pontec PondoSolar fig 4pontec PondoSolar fig 3  Translation of the original Operating Instructions
WARNING

  • This unit can be used by children aged 8 and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved.
  • Do not allow children to play with the unit.
  • Only allow children to carry out cleaning and user maintenance under supervision.
  • Possible death or severe injury from electrocution! Before reaching into the water, disconnect all electrical units in the water from the mains.
  • A damaged connection cable cannot be replaced. Dispose of the unit.

Safety information

  • Do not carry or pull the unit by its electrical cable.
  • Route cables/hoses such that they are protected from damage and do not present a tripping hazard.
  • Only use original spare parts and accessories for the unit.
  • Only operate the pump together with the supplied solar module.
  • Do not allow the pump to run dry.
  • Protect the unit from knocks or vibration.
  • Clean the unit at least twice a year.
  • Keep the connection plugs dry.

Information about these operating instructions
You made a good choice with the purchase of this product PondoSolar 150. Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself with the unit. Ensure that all work on and with this unit is only carried out in accordance with these instructions. Adhere to the safety information for the correct and safe use of the unit. Keep these instructions in a safe place! Please also hand over the instructions when passing the unit on to a new owner.
Warnings used in these instructions
A reference to a figure, e.g. figure A.
→ Reference to another section.

Scope of delivery

A
| Quantity| Description
---|---|---
1| 1| Filter housing
2| 1| Pump with outlet and 5 m connection cable
3| 1| Nozzle holder
4| 4| Nozzle attachment
5| 1| Solar module
6| 1| Ground stake set
7| 4| Nozzle extension

Intended use

Only use the product described in this manual as follows:

  • For creating a water fountain in a pond.
  • For operation with clean water.
  • Operate in accordance with instructions.
  • Operation under observance of the permissible water quality. ( Water quality) The following restrictions apply to the unit:
  • Never use the unit with fluids other than water.
  • Never run the unit without water.
  • Do not use for commercial or industrial purposes.
  • Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
  • Do not connect to the domestic water supply.

Installation and connection

How to proceed: B

  • Assemble the nozzle unit and fit onto the pump. ­ Adapt the number of nozzle extensions used to the depth of the pond.

  • Connect the connection cable to the solar module. ­
    – Push the plug completely into the socket (up to the stop) to ensure that the connection is watertight. ­
    – Switching on: Connect the pump to the solar module. ­
    – Switching off: Disconnect the solar module from the pump.

  • Assemble the ground stake set and attach it to the solar module. ­
    – Ensure that the connection cable is routed downwards.

  • Install the unit in the pond in a horizontal position on firm, sludge-free ground and ensure that it is completely covered with water.

  • Install the solar module so that it is exposed to direct sunlight. ­
    – Recommendation: Align the solar module to the sun to ensure maximum energy yield.

Remedy of faults

Malfunction Cause Remedy
Pump does not start. No connection to the solar module. Connect the pump to

the solar module.
Correctly insert the connection cable.
The solar module is soiled.| Clean
The impeller unit is blocked| Clean
Insufficient or no pump delivery.| The filter is clogged.| Open the pump, remove and clean the filter.
The nozzle unit is clogged.| Remove and clean the nozzle unit.
The impeller unit is worn.| Replace
Insufficient sunlight| Direct sunlight

Maintenance and cleaning

The unit has to be taken out of the water for cleaning or maintenance.
Cleaning the device

  • Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the function.
  • Recommended cleaning agent for removing stubborn limescale deposits:
    – ­Vinegar- and chlorine-free household cleaning agent.

How to proceed:

  1. Disassemble the unit.

  2. Clean the filter housing and impeller unit.

  3. Pull the nozzle unit apart.

  4. Clean all parts.
    – Use a soft brush as an aid. ­
    – Rinse parts in clean water.

  5. Clean the solar module with a damp cloth and wipe dry.

  6. Reassemble the unit in the reverse order.

Replacing the impeller unit
How to proceed: C

  1. Pull the filter housing from the pump.
  2. Remove the foam filter from the filter housing and rinse it out.
  3. Pull the cover off the impeller unit (push-fit fastening, lever out carefully).
  4. Pull out the impeller unit and clean or replace.
  5. Reassemble the unit in the reverse order.

Wear parts
· Impeller unit

Storage/overwintering

Observe the permissible operating temperature range. ( Technical data)

  • If the limit values are exceeded or gone below, it is necessary to remove the unit. Clean the unit thoroughly and check it for damage.
  • Store the pump submerged and in a frost-free environment.

Disposal

NOTE Do not dispose of this unit with domestic waste.

  • Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system provided for this purpose.

Guarantee conditions

PfG grants a 2 year guarantee from the date of sale on proven material and manufacturing faults. Wear parts such as bulbs etc. are exempted from the guarantee. Prerequisite for our guarantee is the presentation of the purchase receipt. Our guarantee will become null and void if the unit is misused, electrically or mechanically damaged by inappropriate use and improper repair by non-authorised workshops. Repairs are reserved for workshops authorised by PfG or by PfG itself. In the case of warranty claims, please return the defective unit or part freight paid to PfG together with a description of the fault and the purchase receipt. PfG reserves the right to invoice repair costs. PfG is not liable for transport damage. Any damage must be claimed against the carrier. Further claims of whatever type, especially consequential damage, are excluded. This guarantee does not affect the final customer’s claims against the dealer.pontec PondoSolar fig 1

| |
---|---|---
Dust tight. Submersible to 0.6 m depth.| Do not dispose of together with household waste!| Attention!
Read the operating instructions
Recommended water quality| pH value| Total hardness| Temperature
---|---|---|---
| 6.8 … 8.5| 8 … 15 °dH| 4 … 35 °C

pontec PondoSolar fig 2

PfG GmbH
Tecklenburger Stage 161
D – 48477 Horstel
Germany
www.pontec.com
**** 40684/11-20

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

pontec User Manuals

Related Manuals