PRODUCT

About this manual

Read all the documentation supplied carefully before installing and using this product. Keep the manual in a convenient place for future reference.

Typographical conventions

DANGER!
High level hazard.
Risk of electric shock. Disconnect the power supply before proceeding with any operation, unless indicated otherwise.

DANGER!
Explosion hazard.
Read carefully to avoid danger of explosion.

CAUTION!
Medium level hazard.
This operation is very important for the system to function properly. Please read the procedure described very carefully and carry it out as instructed.

INFO
Description of system specifications.
We recommend reading this part carefully in order to understand the subsequent stages.

Notes on copyright and information on trademarks
The mentioned names of products or companies are trademarks or registered trademarks. ONVIF® is a trademark of Onvif, Inc.

Product description and type designation

Product marking label
See the label attached to the product.

Model identification

MAXIMUS MVXHD CONFIGURATION OPTIONS WITH CABLE GLAND AND SHIELDED CABLE

 | Voltage| Camera|  | Connections| Video Output| Model|
MVXHD| 2 ** 12-24Vdc/ 24Vac| 10 ** Super low-light Day/ Night camera, FULL HD 1080p, 30x, with DELUX technology| W ** With wiper| A ** Cable gland Ex d 3/4″ NPT and 4m (13ft) armoured cable| Z ** IP H.264/AVC control, ONVIF protocol Profile Q, Profile S and Profile T| 00 ** T5 -60°C/+65°C| B
 |  | 20 ** SONY FCB-EV7520 camera, FULL HD 1080p, 30x|  | B Cable gland Ex d 3/4″ NPT and 10m (32.8ft) armoured cable|  | 02 ** T6 -60°C/+55°C|

Tab. 1

MAXIMUS MVXHD CONFIGURATION OPTIONS WITH CABLE TAIL (FOR INSTALLATION WITH CONDUIT)

 | Voltage| Camera|  | Connections| Video Output| Model|
MVXHD| 2 ** 12-24Vdc/ 24Vac| 10 ** Super low-light Day/ Night camera, FULL HD 1080p, 30x, with DELUX technology| W ** With wiper| F ** 4m (13ft) cable tail| Z ** IP H.264/AVC control, ONVIF protocol Profile Q, Profile S and Profile T| 01 ** T5 -50°C/+65°C| B
 |  | 20 ** SONY FCB-EV7520 camera, FULL HD 1080p, 30x|  | G ** 10m (32.8ft) cable tail|  | 03 **** T6 -50°C/+55°C|

Tab. 2 Conduit sealing fitting and conduit not included.

Installation

  • CAUTION! Device installation and maintaining must be performed by specialist technical staff only.
  • The external multipolar cable shield (armour) must be earthed.
  • All disconnected wires must be electrically isolated.
  • During installation of the version with multipolar cable, ensure there is 200mm of open space at the back of the housing to guarantee correct curvature of the cable.

Range of use
For indoors and outdoors installation. Operating temperature:

  • Continuous working: from -50°C (-58°F) up to + 65°C (149°F).
  • Cold start: up to -40°C (-40°F).

Relative humidity: from 10% up to 95% (no condensation).

Connecting the power supply

  • Electrical connections must be performed with the power supply disconnected and the circuit-breaker open.
  • When commencing installation make sure that the specifications for the power supply for the installation correspond with those required by the device.
  • Check that the power supply is adequately dimensioned.

The device can be provided with different power supply voltages. The power supply voltage is indicated on the product identification label. (3.1 Product marking label, page 3).
Perform the connections following the instructions reported in the table .

CONNECTING THE POWER SUPPLY

Power supply 24Vac/ 24Vdc/ 12Vdc
Colour/Number| Description
24Vac| 24Vdc/12Vdc
Black/1| ~| V+
Black/2| ~| V-
Yellow-Green|  |

Tab. 3

Ethernet cable connection

The Ethernet cable shield must always be earthed via the connector. Always use a shielded RJ45 connector.

Use of Ethernet cables with the following characteristics is highly recommended:

  • STP (shielded)
  • Category 5E
  • RJ45 connector (crimped in compliance with standard TIA/EIA-568-B)

The product can be directly connected to an Ethernet switch.

ETHERNET CABLE CONNECTION

Pin number| Core colour
1| Orange-White
2| Orange
3| Green-White
4| Blue
5| Blue-White
6| Green
7| Brown-White
8| Brown

Tab. 4
The example below shows a typical installation.

I/O cable connection

  • CAUTION! TNV-1 installation type. The installation is type TNV-1, do not connect it to SELV circuits.
  • The shielding of the I/O cable must be grounded.

I/O CABLE CONNECTION

Colour| Function
White| RS-485 A (+)
Yellow| RS-485 B (-)
Pink| Relay 1, Terminal A
Blue| Relay 1, Terminal B
Brown| Alarm/Digital input
Green| GND/Common alarm
Grey| Reset

Tab. 5

Alarm and relay connections
The unit is equipped with the alarms and relays indicated in the table (Tab. 5, page 6).

Connecting an alarm with dry contact
In case of free contact alarm make the connection as shown in the figure.

Clean contact of the alarm can be set NO (normally open) or NC (normally closed) using the web interface.

Relay connection
Each relay is usable with the specifications described below.

  • Working voltage: up to 30Vac or 60Vdc.
  • Current: 1A max.

Use suitable cable sections with the following characteristics: from 0.2mm² (30AWG) up to 1mm² (16AWG).
Due to the absence of polarity, both terminals of the same relay can be connected either to alternating or direct current voltages.

Washing system connection

  • For further details on configuration and use, refer to the relative manual.

Switching on

  • Do not turn on the unit when the ambient temperature is lower than indicated: -40°C.
  • The full functionality of the product is guaranteed from the following ambient temperature: -40°C.
  • The automatic pre-heating procedure (De- Ice) activates for 2 hours if on device switch on an ambient temperature is detected under -10 °C (+14°F). The procedure is necessary to guarantee correct operation of the devices even at low temperatures.

Before powering the product in an explosive atmosphere

  • Make sure that the unit and other components of the installation are closed so that it is impossible to come into contact with live parts.
  • Make sure that the device has been connected to an earth link as described.
  • Ensure the rear cover plate is correctly closed.
  • Ensure the product is correctly closed.
  • Ensure that the sealing of cable entry systems (if any) has been performed properly and the time of glue hardening has been observed.
  • Make sure that all parts are fastened down firmly and safely.

First start-up

  • Ensure the unit and the other components of the system are appropriately closed to prevent contact with live parts.
  • Make sure that all parts are fastened down firmly and safely.

The unit is switched on by connecting the power supply. To switch off the unit disconnect the power.

Configuration

Default IP address
The unit is configured to obtain an IP address from a DHCP server.The IP address acquired via DHCP is visible in the DHCP server log file.
If the DHCP server is not available, the unit automatically configures itself with a self-generated IP address in the 169.254.x.x/16 subnet. Configuring the IP address of the PC as belonging to the same subnet (example: IP address: 169.254.1.1, subnet mask: 255.255.0.0). Use an ONVIF compliant VMS or a network sniffer to find the IP address of the device (IP scan utility).

Web interface
Browsers supported (the latest version): Microsoft Edge, Google Chrome, Mozilla Firefox.

First access to the web pages

  • The first operation in configuring the device consists in connecting to the web interface.
  • To access the web interface of the product, simply use a browser to connect to http://ip_address.
  • On first access, the Home page will be displayed.
  • To configure the web interface, consult the manual relating to the firmware version installed, available on the product web page of the website www.videotec.com.

Accessories

For further details on configuration and use, refer to the manual of the relevant accessory or support.

Maintenance

The pre-installed camera can only be replaced with one of the same brand and model.
Read the product Manual A before performing any operation.

Please provide the device serial number when requesting any replacement parts.

Firmware updating
Firmware upgrading can be carried out directly on the web interface.

  • If necessary it is possible to update the device firmware.
  • For further information please contact the VIDEOTEC service center.

Factory Default
It is possible to reset to the factory default settings. Execute the procedure below:

  • Switch off the unit.
  • Connect the I/O cable grey and green wires (Tab. 5, page 6).
  • Power the unit.
  • Wait 30 seconds.
  • Disconnect the previously connected green and grey wires.
  • Wait for 2 minutes.
  • Switch off the unit.
  • Power the unit.

Once the factory default procedure has finished, you need to configure the unit as described in chapter (6.1 Default IP address, ).

Information on disposal and recycling

The European Directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE) mandates that these devices should not be disposed of in the normal flow of municipal solid waste, but they should be collected separately in order to optimize the recovery stream and recycling of the materials that they contain and to reduce the impact on human health and the environment due to the presence of potentially hazardous substances.

The symbol of the crossed out bin is marked on all products to remember this.

The waste may be delivered to appropriate collection centers, or may be delivered free of charge to the distributor where you purchased the equipment at the time of purchase of a new equivalent or without obligation to a new purchase for equipment with size smaller than 25cm (9.8in).
For more information on proper disposal of these devices, you can contact the responsible public service.

Troubleshooting

Contact an authorized support centre if the problems listed below persist or you have any other issues that are not described here.
Read the product Manual A before performing any operation.

  • PROBLEM Video streaming is not visible.
  • CAUSE Incorrect IP address settings.
  • SOLUTION Check the device IP address and the configuration of the computer network card.
  • CAUSE Automatic preheating procedure (De-Ice) in progress.
  • SOLUTION Wait until the end of the preheating procedure. If the ambient temperature is too low the unit will remain blocked.
  • PROBLEM The wash system is blocked and does not respond to commands.
  • CAUSE The wash system is not enabled.
  • SOLUTION Check the configuration of the settings
  • PROBLEM The wash system settings are incorrect.
  • CAUSE Wrong settings in the configuration.
  • SOLUTION Check the configuration of the settings.

Technical data

For the technical data of the housing, consult Manual A of the product.
Cameras
Day/Night Full HD 30x DELUX

  • Resolution: Full HD 1080p (1920×1080)
  • Image Sensor: 1/2.8″ Exmor™ R CMOS sensor
  • Effective Pixels: approx. 2.38 Megapixels
  • Minimum Illumination:
    • Colour: 0.006lx (F1.6, 30 IRE)
    • B/W: 0.0006lx (F1.6, 30 IRE)
  • Focal length: from 4.5mm (wide) up to 135mm (tele)
  • Zoom: 30x (480x with digital zoom)
  • Iris: from F1.6 up to F9.6 (Auto, Manual)
  • Horizontal Viewing Angle: from 61.60° (wide end) up to 2.50° (tele end)
  • Vertical Viewing Angle: from 37.07° (wide end) up to 1.44° (tele end)
  • Shutter speed: from 1/1s up to 1/10000s (Auto, Manual)
  • White balance: Auto, Manual
  • Gain: from 0dB up to 100dB (Auto, Manual)
  • Wide Dynamic Range: 120dB
  • Focus System: Auto, Manual, Trigger
  • Picture Effects: E-flip, Colour enhancement
  • Noise removal: 2D (3 levels), 3D (3 levels)
  • Exposure Control: Auto, Manual, Priority (Iris Priority, Shutter Priority), Brightness, Custom
  • De-fog : On/Off
  • Privacy zones masking: maximum 8 settable masks
  • Indoor Flicker Reduction
  • Auto Slowshutter: Off, On (from 1/30s up to 1/1s)
  • Exposure compensation : Off, On (from level 0 up to level 14)
  • Sharpness: from level 0 up to level 3

SONY FCB-EV7520 Day/Night Full HD 30x

  • Resolution: Full HD 1080p (1920×1080)
  • Image Sensor: 1/2.8″ Exmor™ R CMOS sensor
  • Effective Pixels: approx. 2.13 Megapixels
  • Minimum Illumination:
    • Colour: 0.0013lx (50 IRE, High sensitivity on)
    • B/W: 0.0008lx (30 IRE, High sensitivity on)
  • Focal length: from 4.3mm (wide) up to 129mm (tele)
  • Zoom : 30x (360x with digital zoom)
  • Iris: from F1.6 up to F14 (Auto, Manual)
  • Horizontal Viewing Angle: from 63.7° (wide end) up to 2.3° (tele end)
  • Vertical Viewing Angle: from 38.5° (wide end) up to 1.3° (tele end)
  • Shutter speed: from 1/1s up to 1/10000s (Auto, Manual)
  • White balance : Auto, Auto Tracing, Indoor, Outdoor, Manual, Outdoor Auto, Sodium Lamp (Fix/Auto/Outdoor Auto)
  • Gain: from 0dB up to 50.0dB (Auto, Manual)
  • Wide Dynamic Range: 120dB
  • Focus System: Auto (PTZ Trigger, Full Auto), Manual
  • Picture Effects: E-flip
  • Noise removal (2D, 3D): Off, On (from level 1 up to level 5)
  • Exposure Control: Auto, Manual, Priority (Shutter priority, Iris priority, Brightness priority)
  • De-fog: Off, Low, Mid, High
  • Dynamic masking of privacy zones: maximum 24 masks settable, maximum 8 simultaneously displayable
  • Indoor Flicker Reduction
  • Gain Limit: from10.7dB up to 50dB
  • High sensitivity: On/Off
  • Backlight Compensation: On/Off
  • Auto Slowshutter: On/Off
  • Exposure compensation: Off, On (from -10.5dB up to +10.5dB)
  • Sharpness: from level 0 up to level 15
  • High Light Compensation (HLC): Off, Low, Mid, High,
  • Masking Level (Off, On, from level 1 up to level 15)
  • Digital image stabilization: On/Off

Headquarters Italy VIDEOTEC S.p.A.
Via Friuli, 6 – I-36015 Schio (VI) – Italy
Tel. +39 0445 697411 – Fax +39 0445 697414 Email: info@videotec.com
www.videotec.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

VIDEOTEC User Manuals

Related Manuals