About this manual
Before installing and using this unit, please read this manual carefully. Be sure to keep it handy for later reference.
1.1 Typographical conventions
DANGER!
High-level hazard.
Risk of electric shock. Disconnect the power supply before proceeding with any
operation, unless indicated otherwise.
CAUTION!
Medium level hazard.
This operation is very important for the system to function properly. Please
read the procedure described very carefully and carry it out as instructed.
INFO
Description of system specifications.
We recommend reading this part carefully in order to understand the subsequent
stages.
Notes on copyright and information on trademarks
The quoted names of products or companies are trademarks or registered trademarks.
Safety rules
CAUTION! The device must be installed only and exclusively by qualified technical personnel.
CAUTION! The electrical system to which the unit is connected must be equipped with a 20A max automatic bipolar circuit breaker. This circuit breaker must be of the Listed type. The minimum distance between the contacts must be 3mm (0.1in). The circuit breaker must be provided with protection against the fault current towards the ground (differential) and the overcurrent (magnetothermal).
- The manufacturer declines all responsibility for any damage caused by improper use of the appliances mentioned in this manual. Furthermore, the manufacturer reserves the right to modify its contents without any prior notice. The documentation contained in this manual has been collected with great care. The manufacturer, however, cannot take any liability for its use. The same thing can be said for any person or company involved in the creation and production of this manual.
- Before starting any operation, make sure the power supply is disconnected.
- Do not use cables that seem worn or old.
- Never, under any circumstances, make any changes or connections that are not shown in this handbook. Improper use of the appliance can cause serious hazards, risking the safety of personnel and of the installation.
- Use only original spare parts. Non-original spare parts could cause fire, electrical discharge, or other hazards.
- Before proceeding with installation, check the supplied material to make sure it corresponds to the order specification by examining the identification labels (4.2 Product markings, page 3).
- The installation category (also called Overvoltage Category) specifies the level of main voltage surges that the equipment will be subjected to. The category depends upon the location of the equipment, and on any external surge protection provided. Equipment in an industrial environment, directly connected to major feeders/short branch circuits, is subjected to Installation Category III. If this is the case, a reduction to Installation Category II is required. This can be achieved by the use of an insulating transformer with an earthed screen between primary and secondary, or by fitting listed Surge Protective Devices (SPDs) from live to neutral and from neutral to earth. Listed SPDs shall be designed for the repeated limiting of transient voltage surges, suitable rated for operating voltage, and designated as follows: Type 2 (Permanently connected SPDs intended for installation on the load side of the service equipment overcurrent device); Nominal Discharge Current (In) 20kA min. For example, FERRAZ SHAWMUT, STT2240SPGCN, and STT2BL240SPG-CN rated 120Vac/240Vac, (In=20kA). The maximum distance between installation and reduction is 5m.
- This device was designed to be permanently installed on a building or on a suitable structure. The device must be installed permanently before any operation.
- When installing the device, comply with all the national standards.
- A disconnecting device, readily and easily accessible, must be incorporated in the electrical system of the building for rapid intervention.
- The separate protective earthing terminal provided on this product shall be permanently connected to the earth.
- For continued protection against the risk of fire, replace only with the same type and rating of the fuse. Fuses must be replaced only by service personnel.
- Equipment intended for installation in Restricted Access Location to trained personnel only.
Identification
4.1 Product description and type designation
Weather-proof box for Pan & Tilt with power supply and control of the
illuminators.
4.2 Product markings
See the label attached to the product.
Preparing the product for use
Any change that is not expressly approved by the manufacturer will invalidate the guarantee.
5.3 Unpacking and contents
5.3.1 Unpacking
When the product is delivered, make sure that the package is intact and that
there are no signs that it has been dropped or scratched.
If there are obvious signs of damage, contact the supplier immediately. Keep
the packaging in case you need to send the product for repairs.
5.3.2 Contents
Check the contents to make sure they correspond with the list of materials as
below:
- Weatherproof box
- Equipment
- Instructions manual
5.4 Safely disposing of packaging material
The packaging material can all be recycled. The installer technician will be
responsible for separating the material for disposal, and in any case for
compliance with the legislation in force where the device is to be used.
When returning a faulty product we recommend using the original packaging for
shipping.
Assembling and installing
Before starting any operation, make sure the power supply is
disconnected.
The assembly and installation must be performed only by skilled
personnel.
6.1 Installation
** Electrical connections must be performed with the power supply
disconnected and the circuit-breaker open.
6.1.1 Open the box**
Open the box taking care not to damage the seals.
After installation and wiring, close the product again.
Position the gaskets correctly and tighten the cable glands.
6.1.2 Board description
Connect the safety earth to the relative terminal of the power supply
connector.
The board may appear different to that illustrated.
**** Depending on the product version, the board may not be equipped with all
functions.
BOARD DESCRIPTION
Connector| Function
J5| Day/Night status
P1| Sensitivity adjustment trimmer
F2| Fuse holder and fuse
Tab. 1
6.1.3 Connection of the power supply line
Earth cable should be about 10mm longer than the other two, so that it
will not be disconnected accidentally if pulled.
All signal cables must be grouped together by means of a strap.
Connect the cables as shown in the figure.
**** Use the supplied gaskets for cables with reduced diameters: From 3mm a 6mm.
6.1.4 Connecting the light-sensitive switch for the LED illuminator
Connect the Day/Night (J5) output identified by STATUS (+) to the alarm input
(refer to the P&T manual).
Connect the second Day/Night (J5) output identified by STATUS to the alarms
common terminal of the P&T.
6.1.5 Connector installation
**** The operation is only to be carried out with UL-certified versions.
Access the lower part of the Pan & Tilt base.
Disassemble the highlighted cable gland to replace it with the provided
connector, taking care not to damage the fixing nut.
6.1.5.1 Wall bracket connector assembly
Assemble the junctions (01 and 02). Fix the assembled junctions onto the base
with the gasket (03) and the nut of the previously removed cable gland (04).
6.1.5.2 Parapet bracket connector assembly
Assemble the junctions (01 and 02). Fix the assembled junctions onto the base
with the gasket (03) and the nut of the previously removed cable gland (04).
6.1.6 Sheath assembly
**** The operation is only to be carried out with UL-certified versions.
The straight cut of conduit.
Push the silicone sheath completely into the connector.
To re-open use a screwdriver.
Configuration
The product has already been set in the factory for optimal operation under a
range of conditions. The product features can be suited to the operating
situation.
Use trimmer P1 to adjust the intervention threshold of the twilight sensor.
(6.1.2 Board description, page4). By rotating the trimmer clockwise, the night
mode changeover is anticipated (at a greater luminous value). By rotating the
trimmer anti-clockwise, the night mode changeover is delayed (at a lower
luminous value).
We recommend making the adjustments under the actual conditions in which the
spots will be used. The switching on of the red LED on the board stands for
the activation of the night-time mode.
Maintaining and cleaning
8.1 Maintaining
** Maintenance must be carried out by personnel trained to operate
electrical circuits.
8.1.1 Fuses replacement**
The used fuse is described below.
T8A L 250 (F2, 6.1.2 Board description, page 4).
Disposal of waste materials
This symbol marks and recycling system are applied only to EU countries and not applied to the countries in the other area of the world.
Your product is designed and manufactured with high-quality materials and
components that can be recycled and reused.
This symbol means that electrical and electronic equipment, at their end of
life, should be disposed of separately from your household waste.
Please dispose of this equipment at your local Community waste collection or
Recycling center. In the European Union, there are separate collection systems
for used electrical and electronic products.
Troubleshooting
Ask for assistance from skilled personnel if:
- The unit is damaged after being dropped;
- There is a noticeable deterioration in the performance of the unit.
- The unit does not work properly, even though all the instructions in this handbook have been followed.
PROBLEM | The unit does not power Pan & Tilt. |
---|---|
CAUSE | Fuses blown. |
SOLUTION | Make sure the power supply data plate values coincide with the |
values for the installation. Check that the green LED inside the box is on.
Make sure there are no current overloads
or short circuits. Change the fuses.
PROBLEM| The unit does not allow the Day/Night changeover of the P&T.
CAUSE| Incorrect wiring or incorrect trimmer regulation
SOLUTION| Ensure that the board STATUS contacts and the alarm contacts are
connected. Reset the twilight sensor sensitivity.
**** If one of the problems listed persists, contact the authorized service center.
Technical data
11.2 Mechanical
Box in aluminum, RAL7035 color
Dimensions: See drawing
Weight: 6kg (13.3lb)
11.3 Electrical
Power supply/Current consumption:
- 230Vac, 1A, 50/60Hz
- 120Vac, 1.7A, 50/60Hz
- 100Vac, 2A, 50/60Hz
Output voltage/Supplied current: 24Vac, 8A max, 50/60Hz
Built-in twilight sensor for automatic switching on and off Day/Night output (STATUS): Dry contact NO
Cables input section: From 3.3mm² (12 AWG) a 2.1mm² (14 AWG) Cables signal section: From 0.52mm² (20 AWG) a 0.13mm² (26 AWG)
11.4 Environment
Indoor/Outdoor
Operating temperature
- Standard box: From -40°C (-40°F) a +60°C (140°F)
- UL certified box: From -40°C (-40°F) a +55°C
11.4.2 Certifications
- IP protection degree: EN60529 (IP66) UL certification: TYPE 4X (UL certified box)
Technical drawings
The dimensions of the drawings are in millimetres.
Headquarters Italy VIDEO TECH s.r.l.
Via Friuli, 6 – I-36015 Schio (VI) – Italy
Tel. +39 0445 697411 – Fax +39 0445 697414
Email: info@videotec.com