VIDEOTEC UPTIRN LED Illuminator Instruction Manual
- June 4, 2024
- VIDEOTEC
Table of Contents
- 1 About this manual
- 2 Notes on copyright and information on trademarks
- 3 Safety rules
- 4 Identification
- 5 Preparing the product for use
- 6 Installation
- 7 Information on disposal and recycling
- 8 Technical data
- 9 Technical drawings
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
VIDEOTEC UPTIRN LED Illuminator Instruction Manual
1 About this manual
Read all the documentation supplied carefully before installing and using this product. Keep the manual in a convenient place for future reference.
1.1 Typographical conventions
2 Notes on copyright and information on trademarks
The mentioned names of products or companies are trademarks or registered trademarks.
3 Safety rules
CAUTION! The white light LED illuminator emits high-intensity visible light. In compliance with standard EN62471/ IEC62471, the photobiological safety assessment has classified the device in Risk Group 2, where it exceeds the values of the Exempt Group. The risk linked to the observer depends on how the product has been installed and is used. For installation, follow the instructions in this manual. Do not open the illuminator for whatever reason. Do not look directly at the illuminator using optical lenses. Exposure hazard values (EHV): 24.3s. Hazard distance (HD): 200mm.
Do not stare at the lamp when on. Can be harmful for eyes.
The infrared LED illuminator emits high intensity visible light. In compliance
with standard EN62471/IEC62471, the photobiological safety assessment has
classified the device in Risk Group 2, where it exceeds the values of the
Exempt Group. The risk linked to the observer depends on how the product has
been installed and is used. For installation, follow the instructions in this
manual. Do not open the illuminator for whatever reason. Do not look directly
at the illuminator using optical lenses. Exposure hazard values (EHV): 88.1s.
Hazard distance (HD): 200mm.
During normal operation the surface of the illuminator can reach high
temperatures. Do not allow direct contact and position the appliance where it
is inaccessible to unauthorised persons. Before touching switch off the
illuminator and allow to cool for a minimum period of 10 minutes.
CAUTION! Device installation and maintaining must be performed by specialist
technical staff only.
- The manufacturer declines all responsibility for any damage caused by an improper use of the appliances mentioned in this manual. Furthermore, the manufacturer reserves the right to modify its contents without any prior notice. The documentation contained in this manual has been collected and verified with great care. The manufacturer, however, cannot take any liability for its use. The same thing can be said for any person or company involved in the creation and production of this manual.
- Before starting any operation, make sure the power supply is disconnected.
- Be careful not to use cables that seem worn or old.
- Never, under any circumstances, make any changes or connections that are not shown in this handbook. Improper use of the appliance can cause serious hazards, risking the safety of personnel and of the installation.
- Use only original spare parts. Non-original spare parts could cause fire, electrical discharge or other hazards.
- Before proceeding with installation, check the supplied material to make sure it corresponds to the order specification by examining the identification labels (4.2 Product marking, page 3).
- A power disconnect device must be included in the electrical installation, and it must be very quickly recognizable and operated if needed.
- Installation category (also called Overvoltage Category) specifies the level of mains voltage surges that the equipment will be subjected to. The category depends upon the location of the equipment, and on any surge voltage protection provided. Equipment in an industrial environment, directly connected to major feeders/short branch circuits, is subjected to Installation Category III. If this is the case, a reduction to Installation Category II is required. This can be achieved by use of an insulating transformer with an earthed screen between primary and secondary windings, or by fitting UL listed Surge Protective Devices (SPDs) from live to neutral and from neutral to earth. Listed SPDs shall be designed for repeated limiting of transient voltage surges and the following rated operation conditions: Type 2 (SPDs permanently connected to the power network and intended for installation on the load side of the service equipment); Nominal Discharge Current (In) 20kA min. For example: FERRAZ SHAWMUT, STT2240SPG-CN, STT2BL240SPG-CN rated 120Vac/240Vac, (In=20kA). Maximum distance between installation and reduction is 5m.
- This is a Class A product. In a domestic environment this product may cause radio interference. In this case the user may be required to take adequate measures.
- To comply with the main supply voltage dips and short interruption requirements, use a suitable Uninterruptable Power Supply (UPS) to power the unit.
- In the case of a 24Vac power supply, you must provide for adequate separation from the AC power supply line using double or reinforced insulation between the main power supply line and the secondary circuit.
4 Identification
4.1 Product description and type designation
State of the art illuminator, which provides high reliability and excellent image quality. The UPTIRN lights the entire scene evenly, eliminating hotspots and underexposures, for unbeatable night-time images and secure surveillance of the area. The high efficiency heat sink body ensures maximum LED durability and protection against over-temperatures, whereas the front glass, made of special techno polymer, provides high infrared transmittance. The illuminators are protected against electrostatic discharges.
4.2 Product marking
See the label attached to the product.
5 Preparing the product for use
Any change that is not expressly approved by the manufacturer will invalidate the guarantee.
5.1 Unpacking
When the product is delivered, make sure that the package is intact and that there are no signs that it has been dropped or scratched. If there are obvious signs of damage, contact the supplier immediately. When returning a faulty product we recommend using the original packaging for shipping. Keep the packaging in case you need to send the product for repairs.
5.2 Contents
Check the contents to make sure they correspond with the list of materials as below:
- Illuminator
- Bolts and screws
- Instruction manual
5.3 Safely disposing of packaging material
The packaging material can all be recycled. The installer technician will be responsible for separating the material for disposal, and in any case for compliance with the legislation in force where the device is to be used.
6 Installation
ℹ This product can be installed only on the ULISSE P&T line. For installation and setting please refer to the P&T manual.
6.3.1 Description of the LED illuminator
- Twilight sensor: Detects the light level.
- Cable: Power supply and control.
- Switch-on threshold regulator: The potentiometer allows adjusting the sensitivity threshold to switch on the illuminator.
- Infrared power control: The potentiometer allows adjusting the power of the illuminator.
7 Information on disposal and recycling
The European Directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE) mandates that these devices should not be disposed of in the normal flow of municipal solid waste, but they should be collected separately in order to optimize the recovery stream and recycling of the materials that they contain and to reduce the impact on human health and the environment due to the presence of potentially hazardous substances.
The symbol of the crossed out bin is marked on all products to remember this.
The waste may be delivered to appropriate collection centers, or may be
delivered free of charge to the distributor where you purchased the equipment
at the time of purchase of a new equivalent or without obligation to a new
purchase for equipment with size smaller than 25cm (9.8in).
For more information on proper disposal of these devices, you can contact the
responsible public service.
8 Technical data
8.1 General
Wavelengths: 850nm, 940nm, white light Adjustable built-in twilight sensor for automatic activation and deactivation
8.2 Mechanical
Die cast aluminum body
Dimensions: 187x111x176mm (7.4×4.4×6.9in)
Unit weight: 1.5kg (3.3lb)
8.3 Electrical
Supply voltage/Current consumption:
- from 12Vdc a 24Vdc, 2.5A max
- 24Vac, 2.5A max, 50/60Hz
8.4 Illuminators
8.5 Environment
For indoors and outdoors installation Operating temperature: from -40°C (-40°F) a +60°C (140°F)
8.6 Certifications
9 Technical drawings
Headquarters Italy Videotec s.r.l. Via Friuli, 6 – I-36015 Schio (VI) – Italy
Tel. +39 0445 697411 – Fax +39 0445 697414 Email:
info@videotec.com
www.videotec.com
MNVKUPTIRN_2222_EN
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>