VIDEOTEC Punto Side Opening Technopolymer Camera Housing Instruction Manual
- June 4, 2024
- VIDEOTEC
Table of Contents
- VIDEOTEC Punto Side Opening Technopolymer Camera Housing
- Description of system specifications
- Safety rules
- Identification
- Preparing the product for use
- Assembling and installing
- Maintaining and cleaning
- Disposal of waste materials
- Technical data
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
VIDEOTEC Punto Side Opening Technopolymer Camera Housing
About this manual
Before installing and using this unit, please read this manual carefully. Be sure to keep it handy for later reference.
Typographical conventions
DANGER!
High level hazard.
Risk of electric shock. Disconnect the power supply before proceeding with any
operation, unless indicated otherwise.
CAUTION!
Medium level hazard.
This operation is very important for the system to function properly. Please
read the procedure described very carefully and carry it out as instructed.
INFO
Description of system specifications
We recommend reading this part carefully in order to understand the subsequent stages.
Notes on copyright and information on trademarks
The quoted names of products or companies are trademarks or registered
trademarks.
Safety rules
CAUTION! The device must be installed only and exclusively by qualified technical personnel.
CAUTION! The electrical system to which the unit is connected must be
equipped with a 10A max automatic bipolar circuit breaker. This circuit
breaker must be of the Listed type. The minimum distance between the contacts
must be 3mm (0.1in). The circuit breaker must be provided with protection
against the fault current towards the ground (differential) and the
overcurrent
(magnetothermal).
- The manufacturer declines all responsibility for any damage caused by an improper use of the appliances mentioned in this manual. Furthermore, the manufacturer reserves the right to modify its contents without any prior notice. The documentation contained in this manual has been collected with great care. The manufacturer, however, cannot take any liability for its use. The same thing can be said for any person or company involved in the creation and production of this manual.
- Before starting any operation, make sure the power supply is disconnected.
- Do not use cables that seem worn or old.
- Never, under any circumstances, make any changes or connections that are not shown in this handbook. Improper use of the appliance can cause serious hazards, risking the safety of personnel and of the installation.
- Use only original spare parts. Non-original spare parts could cause fire, electrical discharge or other hazards.
- Before proceeding with installation, check the supplied material to make sure it corresponds to the order specification by examining the identification labels (4.2 Product markings, page 4).
- This device was designed to be permanently installed on a building or on a suitable structure. The device must be installed permanently before any operation.
- When installing the device, comply with all the national standards.
- Any device which could be installed inside the product must comply with the current safety standards.
- For all connections, use cables that are able to withstand temperatures of at least 75°C (167°F).
- Installation category (also called Overvoltage Category) specifies the level of mains voltage surges that the equipment will be subjected to. The category depends upon the location of the equipment, and on any external surge protection provided. Equipment in an industrial environment, directly connected to major feeders/short branch circuits, is subjected to Installation Category III. If this is the case, a reduction to Installation Category II is required. This can be achieved by use of an insulating transformer with an earthed screen between primary and secondary, or by fitting listed Surge Protective Devices (SPDs) from live to neutral and from neutral to earth. Listed SPDs shall be designed for repeated limiting of transient voltage surges, suitable rated for operating voltage and designated as follows: Type 2 (Permanently connected SPDs intended for installation on the load side of the service equipment overcurrent device); Nominal Discharge Current (In) 20kA min. For example: FERRAZ SHAWMUT, STT2240SPG-CN, STT2BL240SPG-CN rated 120Vac/240Vac, (In=20kA). Maximum distance between installation and reduction is 5m.
- The product must be fastened with suitable equipment. The fastening means must guarantee the mechanical seal when a force equal to at least 4 times the weight of the device is applied.
- Respect the national standards for the connection of the mains and of the earth conductor during installation of the device.
- The product is designed to house only cameras that are properly certified (7W max).
- A disconnecting device, readily and easily accessible, must be incorporated in the electrical system of the building for rapid intervention.
Identification
Product description and type designation
This stylish technopolymer housing has been designed to accommodate a variety
of cameras and lenses Very easy to install thanks to the side opening system
that allows the full access to the camera, lenses and all internal
connections. The front is designed to offer protection from UV rays and
atmospheric agents. The housing proposes various mounting options, wall or
ceiling brackets, feedthrough and non-feedthrough, or Pan & Tilt head.
A wide range of accessories for mounting the equipment is available thereby
satisfying all installation needs.
Product markings
See the label attached to the product.
Preparing the product for use
Any change that is not expressly approved by the manufacturer will invalidate the guarantee.
Unpacking and contents
Unpacking
When the product is delivered, make sure that the package is intact and that
there are no signs that it has been dropped or scratched.
If there are obvious signs of damage, contact the supplier immediately.
Keep the packaging in case you need to send the product for repairs.
Contents
Check the contents to make sure they correspond with the list of materials as
below:
- Housing
- Housing equipment
- Instructions manual
- Desiccant bag
Safely disposing of packaging
material
The packaging material can all be recycled. The installer technician will be
responsible for separating the material for disposal, and in any case for
compliance with the legislation in force where the device is to be used.
When returning a faulty product we recommend using the original packaging for
shipping.
Preparatory work before installation
Attaching the bracket
The product must be fastened with suitable equipment. The fastening means must guarantee the mechanical seal when a force equal to at least 4 times the weight of the device is applied.
Assembling and installing
The assembly and installation must be performed only by skilled personnel.
Assembly
How to open the housing
Loosen the 2 screws on the side, turn the cover and the upper half of the body
about the opening hinge axis.
Fig. 1
Cable glands assembly
The cable glands are suitable for cables with a diameter between 5mm and 10
mm.
Fix the cable glands as shown in the figure.
Support with external cable passage..
Support with internal cable passage..
Fixing the sunshield
It’s possible to fix the sunshield to the housing using screws, washers and
spacers provided.
Fig. 4
Installation
Fixing of housing to support
Apply a thread-locker on the holes of the screws (Loctite 243®).
Fix the housing to the support using the supplied
screws. Fixing on support with
external cable passage. Fixing on support with internal cable passage.
How to install the camera
Fasten the camera with the 1/4″ screw (03). To position the camera and lens
correctly, if necessary, use the supplied spacers.
(04).
Fig. 7
Fasten down the adjustable slide in the correct position using the appropriate
screws.
Connection of the version with connector board
- Earth cable should be about 10mm longer than the other two, so that it will not be disconnected accidentally if pulled.
- The power supply cable conductors must be tied up with a cable tie next to the terminal.
- Make sure the external power supply source corresponds to the camera power supply requirements.
The cable gland must grip the cable sheath. Make sure the cable sheath protrudes at least 5 mm beyond the cable gland.
Fig. 9
Connect the camera power supply cable to terminal J4. Connect the external
power supply cable to terminal J3.
Fig. 10
Closing the housing
Take the dessicant salt bag out of its pack and insert it into the product. At
the end of the installation close the housing.
Maintaining and cleaning
Before doing any technical work on the device, disconnect the power supply.
Window and plastic cover cleaning
Avoid ethyl alcohol, solvents, hydrogenated hydrocarbide, strong acid and
alkali. Such products may irreparably damage the surface.
We recommend using a soft cloth with neutral soaps diluted with water or
specific products to clean the glasses lenses.
Disposal of waste materials
This symbol mark and recycle system are applied only to EU countries and not
applied to the countries in the other area of the world.
Your product is designed and manufactured with high quality materials and
components which can be recycled and reused.
This symbol means that electrical and electronic equipment, at their end-of-
life, should be disposed of separately from your household waste.
Please dispose of this equipment at your local Community waste collection or
Recycling centre.
In the European Union there are separate collection systems for used
electrical and electronic products.
Technical data
General
Entirely made of technopolymer
RAL9002 Colour
Stainless steel external screws
Mechanical
Cable glands: 2xM16
Glass window (WxH): 60/95x63mm (2.4/3.7×2.5in) Internal usable area (WxH):
70x70mm (2.7×2.7in) Internal usable length (with or without accessories):
250mm (9.8in)
Unit weight: 0.8kg (1.7lb)
Electrical
Power supply/Current consumption (empty version):
- From 12Vdc a 24Vdc, 1A max
- From 12Vac a 24Vac, 1A max, 50/60Hz
- From 120Vac a 230Vac, 400mA max, 50/60Hz
Power supply/Current consumption (version with heater, Ton 15°C±3°C (59°F ±5°F), Toff 22°C±3°C (77°F±5°F)):
- From 12Vdc a 24Vdc, 3A max
- From 12Vac a 24Vac, 3A max, 50/60Hz
- From 120Vac a 230Vac, 400mA max, 50/60Hz
Environment
Indoor/Outdoor
Operating temperature with heating: From -20°C (-4°F) a +60°C (140°F)
Chemical agents resistance
- High resistance: basics, alcohols, gas, hydrocarbon
- Good resistance: Organic acids, inorganic acids, oils
- Low resistance: Solvents
Certifications
Electrical safety (CE): EN60950-1, IEC60950-1, EN62368-1, IEC62368-1
Electromagnetic compatibility (CE): EN50130-4, EN61000-6-3
Outdoor installation (CE): EN60950-22, IEC 60950-22 IP protection degree:
EN60529, IP66
UL certification: cULus Listed (TYPE 4X) (only versions from 12Vdc up to 24Vdc
and from 12Vac up to 24Vac)
EAC certification