KICHLER 34808A Mini Pendant Instruction Manual

October 28, 2023
KICHLER

KICHLER 34808A Mini Pendant

PACKAGE CONTENTS

PART DESCRIPTION QTY.
A Canopy 1
B Mounting Bracket 1
C Threaded Nipple 1
D Hex Nut 3
E Socket 1
F Coupling 1
G Shade 1
H Screw Collar Ring 1
PART DESCRIPTION QTY.
--- --- ---
I Screw Collar Loop 1
J Threaded Pipe 1
K Chain 1
L Fixture Loop 1
M Socket Ring 1
N Arm 3
O Cage Ring 2
P Threaded Chain Link 2
HARDWARE CONTENTS
SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate or install the product.

WARNING

  • CAUTION – RISK OF SHOCK
    Disconnect Power at the main circuit breaker panel or main fusebox before starting and during the installation.

  • WARNING:
    This fixture is intended for installation in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended.

  • Do not use bulbs with wattage greater than specified on this fixture.

  • California Proposition 65
    WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer, birth defects, or other reproductive harm.
    For more information, go to http://www.P65Warnings.ca.gov

CAUTION

  • If you have any doubts about how to install this lighting fixture, or if the fixture fails to operate completely, please contact a licensed electrical contractor.
  • All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to obey this instruction could invalidate ETL listing and/or C.S.A. certification of this fixture.
PREPARATION

Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list and hardware contents list. If any part is missing or damaged, do not attempt to assemble the product.

  • Estimated assembly time: 30 minutes to 1 hour
  • Tools Required for Assembly (not included): Phillips screwdriver, flathead screwdriver, wire strippers, electrical tape, ladder, safety glasses.

ASSEMBLY INSTRUCTIONS

  1. Screw threaded pipe (J) onto coupling (F).
    Screw fixture loop (L) onto threaded pipe (J).

  2. Position threaded nipple (C) in mounting bracket (B) so when mounted:

    • The threaded nipple (C) will protrude a minimum of 1/4 inch beyond the raised center portion of the mounting bracket (B).
    • The threaded nipple (C) height is positioned so 1/2 the exterior threads of the screw collar loop (I) will extend past the canopy (A) when it is mounted.
      NOTE: Canopy is only needed to determine the position of the threaded nipple and fixture loop. It will be installed later.
  3. Once the proper position of the threaded nipple (C) and mounting bracket (B) has been determined, secure with hex nuts (D) as follows:

    • Screw one hex nut (D) onto the threaded nipple (C) and tighten against the raised portion of the mounting bracket (B).
    • Screw another hex nut (D) onto the threaded nipple (C) and tighten against the flat portion of the mounting bracket (B).
    • Screw the remaining hex nut (D) onto threaded nipple (C) and tighten against the screw collar loop (I).
  4. Connect mounting bracket (B) to the outlet box with short machine screws (BB). Hardware Used

  5. Thread chain (K) though screw collar ring (H) and canopy (A). Using the threaded chain links (P) on chain (K), attach one end to screw collar loop (I) and the other end to upper fixture loop (L). Weave the fixture electrical and ground wires through every other chain link and pass through threaded nipple (C) into outlet box. Lower the screw collar ring (H) and canopy (A) over the chain (K).

  6. Wire connection guide:

Ground wire:

  * For installation in the United States: Wrap ground wire from outlet box around ground screw preassembled on mounting bracket (B) no less than 2 in. from wire end. Tighten ground screw. If fixture is supplied with a ground wire, connect to outlet ground wire with a wire connector (AA).
  * For installation in Canada: If fixture is supplied with ground wire, wrap ground wire around ground screw on mounting bracket (B). Tighten ground screw. Connect fixture ground wire to outlet ground wire with the wire connector (AA).  

Supply wires:

  * Connect the Neutral (White) supply wire from the outlet box to the Neutral fixture wire (White or Parallel Cord “D” shaped and ribbed).
  * Connect the Hot (Black) supply wire from the outlet box to the Hot fixture wire (Black or Parallel Cord round and smooth).  

NOTE:
Fixture wires will either be:

  * Black and White.
  * Parallel Cord SPT-1 lamp wire with one round smooth wire and one “D” shaped ribbed wire.  

Hardware Used

  1. Pass canopy (A) over the screw collar loop (I). Attach screw collar ring (H) to screw collar loop (I) to secure canopy (A).
  2. Secure arms (N) to coupling (F) using a coupling screw (CC). Raise cage rings (O) to arms (N). Pass arm screw (DD) through cage ring (O) and secure with arm knob (EE). Hardware Used
  3. Pass shade (G) over socket (E) and secure with socket ring (M).
  4. Insert 60-watt max. medium base bulb or LED equivalent (not included) into socket (E).

CARE AND MAINTENANCE

  • Always be certain that electric current is turned off before cleaning this item.
  • Use a soft, moist cloth with mild non-abrasive soap to clean fixture. Never use glass cleaner on fixture, as it will damage the metal finish.
  • All glass shades may be washed in a towel-lined sink with warm water and mild soap. Do not wash shades in an automatic dishwasher.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Fixture does not light.
  1. Fixture may be wired incorrectly.
  2. Worn or broken bulb.

|

  1. Check wiring.
  2. Replace bulb.