The product is a lighting fixture that comes with a rigid stem mount. The fixture consists of stems, short threaded tubes, a coupler, a canopy, a mounting strap, a loop, an open chain link, a mounting screw, an end tube cap, a lock-up knob, decorative ends, decorative tube, and a hex coupler. The fixture is designed to be mounted on an outlet box and provides a ground wire connector for safety purposes.

Product Usage Instructions

  1. Remove the loop from the canopy by unscrewing the hex nut and removing the lock washer. Set aside the hex nut and lock washer for use later in the assembly.

  2. Thread decorative ends into couplings on the bottom of the fixture arms as shown. Tighten to secure.

  3. Thread long threaded rod into hex coupler as shown. Apply thread locking compound to all stem threads to prevent accidental rotation of fixture during cleaning, re-lamping, etc.

  4. Carefully slip the decorative tube over the installed long threaded rod.

  5. Place the end tube cap on top of the installed decorative tube.

  6. Pass fixture wires through the coupler and thread coupler onto threads protruding from the top of the end tube cap, applying thread locker where noted with symbol (). Tighten to secure assembly.

  7. Pass fixture wires from the coupler through the desired number of stems and short threaded tubes. Screw stems together using short threaded tubes, applying thread locker where noted with the symbol ().

  8. Screw the first stem into the coupler.

  9. Unscrew the short threaded tube from the loop.

  10. Pass fixture wires from the last stem through the short threaded tube and screw the short threaded tube into the top of the last stem.

  11. Pass fixture wires from stem(s) through the center hole in the canopy.
    Carefully lower the canopy down toward the stem(s) and slip the canopy over the short threaded tube protruding from the top of the stem(s).

  12. Pass fixture wires through the lock washer and then through the hex nut. Slip the lock washer onto the short threaded tube protruding from the inside canopy, and the screw hex nut onto the short threaded tube. Tighten to secure.

  13. Cut fixture wires a minimum of 20 inches from the top edge of the canopy.

  14. Find the appropriate threaded holes on the mounting strap that align with the hole distance in the canopy. Screw mounting screws into threaded holes starting from the outlet box side.

  15. Attach mounting strap to the outlet box using the strap mounting screws. The mounting strap can be adjusted to suit the position of the fixture.

  16. For grounding instructions, refer to Illus. a or b. Connect fixture ground wire to outlet box ground wire with wire connector after following the above steps. Never connect the ground wire to black or white power supply wires.

FIXTURE DIAGRAM

KICHLER Ali-Chandelier52500BNB-Ali-Chandelier-
FIG-1

INSTALLATION INSTRUCTIONS

RIGID STEM MOUNT INSTRUCTIONS

  1. Remove loop[P] from canopy[D] by unscrewing hex nut[T] and removing lock washer[S]. Set aside hex nut and lock washer for use later in the assembly.

  2. Thread decorative ends[Q] into couplings on the bottom of the fixture arms as shown. Tighten to secure.

  3. Thread long threaded rod[O] into hex coupler[U] as shown.
    NOTE: Thread locking compound must be applied to all stem threads as noted with symbol (4) to prevent accidental rotation of fixture during cleaning, re-lamping, etc.

  4. Carefully slip decorative tube[N] over installed long threaded rod.

  5. Place end tube cap[K] on top of installed decorative tube.

  6. Pass fixture wires through coupler[C] and thread coupler onto threads protruding from top of end tube cap, applying thread locker where noted with symbol (4). Tighten to secure assembly.

  7. Pass fixture wires from coupler through desired number of stems[A] and short threaded tubes[B]. Screw stems together using short threaded tubes, applying thread locker where noted with symbol (4).

  8. Screw first stem into coupler[C].

  9. Unscrew short threaded tube[B] from loop[H].

  10. Pass fixture wires from last stem through short threaded tube[B] and screw short threaded tube into top of last stem.

  11. Pass fixture wires from stem(s) through center hole in canopy[D]. Carefully lower canopy down towards stem(s) and slip canopy over short threaded tube protruding from top of stem(s).

  12. Pass fixture wires through lock washer[S] and then through hex nut[T]. Slip lock washer onto short threaded tube protruding from inside canopy, and the screw hex nut onto short threaded tube. Tighten to secure.

  13. Cut fixture wires a MINIMUM of 20 inches from the top edge of canopy.

  14. Find the appropriate threaded holes on mounting strap[G] that align with hole distance in canopy[D]. Screw mounting screws[J] into threaded holes starting from the outlet box side.

  15. Attach mounting strap to outlet box[F] using the strap mounting screws[E]. Mounting strap can be adjusted to suit position of fixture.

  16. Grounding instructions: (See Illus. a or b).

    • a. On fixtures where mounting strap is provided with a hole and two raised dimples, wrap ground wire from outlet box around green ground screw, and thread into hole.
    • b. On fixtures where a cupped washer is provided, attach ground wire from outlet box under cupped washer and green ground screw, and thread into mounting strap.
    • If fixture is provided with ground wire, connect fixture ground wire to outlet box ground wire with wire connector after following the above steps. Never connect ground wire to black or white power supply wires.KICHLER Ali-Chandelier52500BNB-Ali-Chandelier-FIG-2
  17. Make wire connections. Reference chart below for correct connections and wire accordingly
    Connect Black or Red Supply Wire to:| Connect White Supply Wire to:
    ---|---
    Black| White
    Parallel cord (round & smooth)| Parallel cord (square & ridged)
    Clear, Brown, Gold or Black without Tracer| Clear, Brown, Gold or Black with Tracer
    Insulated wire (other than green) with copper conductor| Insulated wire (other than green) with silver conductor
    *Note: When parallel wire (SPT 1 & SPT 2) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (See illus.)|

Neutral Wire

  1. Raise fixture to ceiling, carefully passing mounting screws through mounting screw holes in canopy.
    • NOTE: Make sure wires do not get pinched between mounting strap and canopy or canopy and ceiling.
  2. While holding canopy in place, slip lock washers[M] over threads protruding through holes in canopy (2 places) and then screw lock-up knobs[L] onto threads protruding through holes in canopy (2 places) to secure fixture to ceiling. Tighten to secure.
  3. Carefully slip shades[R] over sockets[V] until seated on socket bases.
  4. Install recommended bulb(s), not supplied.
LOOP/CHAIN LINK MOUNT INSTRUCTIONS
  1. Follow steps 2-10 from RIGID STEM MOUNT INSTRUCTIONS.
  2. Pass fixture wires from last stem through first loop[H]. Screw first loop onto short threaded tube attached to last stem, applying thread locker where noted with symbol (4).
  3. Insert short threaded tube at end of second loop[P] through center hole in canopy.
    • NOTE: If second loop is already attached to canopy, skip ahead to step #5.
  4. Slip lock washer onto short threaded tube protruding from inside canopy and then screw hex nut onto short threaded tube. Tighten to secure.
  5. Connect loop[H] to loop[P] using open chain link[I]. Close the open chain link by placing a piece of cloth over the open link and using a pair of pliers to gently squeeze the link closed.
  6. Pass fixture wires through loop[P] and into canopy[D].
  7. Follow Steps 13-21 from RIGID STEM MOUNT INSTRUCTIONS

PARTS LIST

  • [A] Stems (2-6”, 2-12”)
  • [B] Short Threaded Tubes (Qty. 8)
  • [C] Coupler
  • [D] Canopy
  • [E] Strap Mounting Screw
  • [F] Outlet Box (Not Supplied)
  • [G] Mounting Strap
  • [H] Loop (First Loop)
  • [I] Open Chain Link
  • [J] Mounting Screw
  • [K] End Tube Cap
  • [L] Lock-up Knob (Qty. 2)
  • [M] Lock Washer (Qty. 2)
  • [N] Decorative Tube
  • [O] Long Threaded Rod
  • [P] Loop (Second Loop, Attached to Canopy)
  • [Q] Decorative Ends
  • [R] Shade
  • [S] Lock Washer
  • [T] He Nut
  • [U] Hex Coupler
  • [V] Socket

CAUTION – RISK OF SHOCK:
Disconnect Power at the main circuit breaker panel or main fusebox before starting and during the installation.
WARNING:
This fixture is intended for installation in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended. Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void the warranty.
CLEANING:

  • Always be certain that electric current is turned off before cleaning.
  • Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.

For warranty information please visit: kichler.com/warranty

Documents / Resources

| KICHLER 52500BNB Ali Chandelier [pdf] Instruction Manual
52500BNB, 52502BNB, 52500BK, 52502BK, 52500BNB Ali Chandelier, Ali Chandelier, Chandelier
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

KICHLER User Manuals

Related Manuals