Product Information
This product is a lighting fixture that comes with a mounting strap, support cables, and a safety cable. It also includes a main body, candle sleeve, canopy, strap mounting screws, cable strain relief, lock-up knobs, mounting screws, lock washers, power wire, socket, and a parts list. The fixture is designed to be mounted on an outlet box and adjusted to suit the position of the fixture. It comes with grounding instructions and a wire connection chart for proper connection.
Product Usage Instructions
- Find the appropriate threaded holes on the mounting strap that align with the hole distance in the canopy.
- Screw mounting screws into threaded holes starting from the outlet box side.
- Attach the mounting strap to the outlet box using the strap mounting screws. Adjust the mounting strap to suit the position of the fixture.
- Adjust each support cable to the desired length. To shorten the cable, push up on the cable at the cable strain relief attached to the canopy and push the cable into the canopy. To lengthen the cable, push up on the cable strain relief and gently pull down on the cable to the desired length. Adjust the length of the power wire simultaneously by gently pulling the wire out of the canopy or pushing it into the canopy.
- Cut fixture wires a minimum of 20 inches from the top edge of the canopy.
- Attach the safety cable to the mounting plate or to the inside of the outlet box and secure it into place to prevent damage to the wires during wiring.
- Grounding instructions: Refer to Illus. a or b. Follow instructions accordingly if fixture is provided with ground wire.
- Make wire connections according to the wire connection chart provided.
- Raise the fixture to the ceiling, carefully passing mounting screws through mounting screw holes in the canopy. Make sure wires do not get pinched between the mounting strap and the canopy or canopy and ceiling.
- While holding the canopy in place, slip lock washers over threads protruding through holes in the canopy (2 places) and then screw lock-up knobs onto threads protruding through holes in the canopy (2 places) to secure the fixture to the ceiling. Tighten to secure.
FIXTURE DIAGRAM
PARTS LIST
- [A] Main Body
- [B] Candle Sleeve
- [C] Outlet Box (Not Supplied)
- [D] Canopy
- [E] Strap Mounting Screw (qty. 2)
- [F] Cable Strain Relief
- [G] Mounting Strap
- [H] Safety Cable
- [I] Lock-up Knob (qty. 2)
- [J] Mounting Screw (qty. 2)
- [K] Lock Washer (qty. 2)
- [L] Support Cable
- [M] Power Wire
- [N] Socket
CAUTION: RISK OF SHOCK:
- Disconnect Power at the main circuit breaker panel or main fusebox before starting and during the installation.
WARNING
- This fixture is intended for installation in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended. Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void the warranty.
CLEANING
- Always be certain that electric current is turned off before cleaning.
- Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.
INSTALLATION INSTRUCTIONS
- Find the appropriate threaded holes on mounting strap[G] that align with hole distance in canopy[D]. Screw mounting screws[J] into threaded holes starting from the outlet box side.
- Attach mounting strap to outlet box[C] using the strap mounting screws[E]. Mounting strap can be adjusted to suit position of fixture.
- Adjust each support cable[L] to the desired length. To shorten the cable, push up on the cable at the cable strain relief[F] attached to the canopy and push cable into canopy. To lengthen the cable, push up on the cable strain relief and gently pull down on the cable to the desired length. Adjust the length of the power wire[M] simultaneously by gently pulling wire out of canopy or pushing wire into canopy.
- Cut fixture wires a MINIMUM of 20 inches from the top edge of canopy.
- Attach the safety cable[H] to the mounting plate or to the inside of the outlet box and secure into place to prevent damage to the wires during wiring.
- Grounding instructions: (See Illus. a or b).
- On fixtures where mounting strap is provided with a hole and two raised dimples, wrap ground wire from outlet box around green ground screw, and thread into hole.
- On fixtures where a cupped washer is provided, attach ground wire from outlet box under cupped washer and green ground screw, and thread into mounting strap .If fixture is provided with ground wire, connect fixture ground wire to outlet box ground wire with wire connector after following the above steps. Never connect ground wire to black or white power supply wires.
- Make wire connections. Reference chart below for correct connections and wire accordingly.
Connect Black or Red Supply Wire to:| Connect White Supply Wire to:
---|---
Black| White
Parallel cord (round & smooth)| Parallel cord (square & ridged)
Clear, Brown, Gold or Black without Tracer| Clear, Brown, Gold or Black with Tracer
Insulated wire (other than green) with copper conductor| Insulated wire (other than green) with silver conductor
Note: When parallel wire (SPT 1 & SPT 2) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (See illus.)| - Raise fixture to ceiling, carefully passing mounting screws through mounting screw holes in canopy.
- NOTE: Make sure wires do not get pinched between mounting strap and canopy or canopy and ceiling.
- While holding canopy in place, slip lock washers[K] over threads protruding through holes in canopy (2 places) and then screw lock-up knobs[I] onto threads protruding through holes in canopy (2 places) to secure fixture to ceiling. Tighten to secure.
- Slide candle sleeves[B] down over the sockets[N] of the main body[A]. Repeat for all sockets.
- Install recommended bulb(s), not supplied.