INTRODUCTION
The device is a single door multifunction standalone access controller or a Wiegand output reader. The operation is very user-friendly, and low-power circuit makes it long service life.
Features
- Metal case, anti-vandal
- Waterproof, conforms to IP65
- Video calling based on WiFi
- Full duplex voice intercom
- One relay, 1,000 users (990 common + 10 visitor)
- PIN length: 4~6 digits
- Card type: 125KHz EM Card
- Can be used as Wiegand reader with buzzer output
- Card block enrollment
- Tri-color LED status display
- Pulse mode, Toggle mode
Specifications
Carton Inventory
INSTALLATION
- Remove the back cover from the unit
- Drill 2 holes(A,C) on the wall for the screws and one hole for the cable
- Knock the supplied rubber bungs to the screw holes(A,C)
- Fix the back cover firmly on the wall with 4 flat head screws
- Thread the cable through the cable hole(B)
- Attach the unit to the back cover
Wiring
Sound and Light Indication
Basic Configure
Enter and Exit Program Mode
Set Master Code
Set the Working Mode
Notes: The device has 3 working modes: Standalone Mode, Controller Mode,
Wiegand Reader Mode, choose the mode you use. (Factory default is Standalone
Mode / Controller Mode)
STANDALONE MODE
The device can work as Standalone Access Control for single door.
(Factory default mode) – 7 7 #
Connection Diagram
Common Power Supply
Attention:
Install a 1N4004 or equivalent diode is needed when use a common power supply,
or the keypad might be damaged. (1N4004 is included in the packing)
Access Control Power Supply
Programming
Programming will be vary depending on access configuration. Follow the
instructions according to your access configuration.
Notes:
User ID number: Assign a user ID to the access fingerprint/ card/ PIN in order to track it.
The Common User ID:
Fingerprint version:
- Fingerprint user ID: 0 ~ 98
- Card user ID: 100 ~ 989
- Master Fingerprint User ID: 99
- Visitor User ID: 990~999
Other two versions:
- PIN/Card User ID: 0~989
- Visitor User ID: 990~999
IMPORTANT: User IDs do not have to be proceeded with any leading zeros.
Recording of User ID is critical. Modifications to the user require the User
ID be available.
-
Proximity Card:
Proximity Card: 125KHz EM card -
PIN: Can be any 4~6 digits except 8888
Add Common Users
Tips for PIN Security (Only valid for 6 digits PIN):
For higher security we allow you to hide your correct PIN with other numbers
up to a max of 10 digits.
Example PIN: 123434
You could use (123434) or * (123434)
(“” can be any numbers from 0~9)
# Note: This function for keypad version only
Add Master Fingerprint (By Specified ID: 99, Fingerprint version only
)
Add Visitor Users (Valid for Card/ PIN Users)
(User ID number is 990~999; PIN length: 4~6 digits except 8888) There are 10
groups Visitor PIN/card available, the users can be specified up es of usage,
after a certain number of times, i.e. 5 times, the PIN/card become invalid
automatically.
Change PIN Users (PIN length: 4~6 digits except 8888)
(Keypad version only)
Delete Users
Set Relay Configuration
The relay configuration sets the behaviour of the output relay on activation
.
Set Access Mode
For Multi user access mode, the interval time of reading can not exceed 5
seconds, or else, the device will exit to standby automatically
Set Strike-outAlarm
The strike-out alarm will engage after 10 failed entry attempts (Factory is
OFF).
It can be set to deny access for 10 minutes after engaging or disengage only
after entering a valid Finerprint/ card/ PIN or Master code/ fingerprint/ card
.
Set Audible and Visual Response
Users Operation & Reset to Factory Default
- Open the door: Read valid user fingerprint or user card or input valid user PIN #
- Remove Alarm: Enter Master Code # or Master Fingerprint/ Card or valid user fingerprint / card / PIN
- To reset to factory default & Add Master Card: Power off, press the Exit Button, hold it and power on, there will be two beeps, then release the exit button, the LED light turns into yellow, then read any 125KHz EM card, the LED will turn into red, means reset to factory default successfully. Of the card reading, it is the Master Card.
Remarks:
- If no Master Card added, must press the Exit Button for at least 5 seconds before release.(this will make the previous registered Master Card invalid
- Reset to factory default, the user’s information is still retained.
Master Fingerprint/ Card Usage (Master Card is not default accessory in the box, please add by yourself if needed)
CONTROLLER MODE
The device can work as Controller, connected with the external Wiegand reader.
(Factory default mode) —7 7 #
Connection Diagram
Attention: Install a 1N4004 or equivalent diode is needed when use a common power supply, or the reader might be damaged. (1N4004 is included in the packing)
Set Wieg and Input Formats
Please set the Wiegand input formats according to the Wiegand output format of
the external Reader.
Note: For connecting Wiegand readers with 32, 40 bits output, need disable parity bits.
Programming
-
Basic Programming is the same as Standalone Mode
-
There are some exceptions for your attention:
The device Connected with External Card Reader- If EM card reader: users can be added/deleted on either the device or external reader.
- If HID or Mifare card reader : users can only be added/deleted on extemal reader.
The device Connected with Fingerprint Reader
For example:
Connect SF1 as the fingerprint reader to the device.
Step 1: Add the Fingerprint (A) on SF1 (Please refer to SF1 manual)
Step 2: Add the same Fingerprint(A) on the device:
The device Connected with Keypad Reader
The keypad reader can be 4 Bits, 8 Bits (ASCII), or 10 Bits output format.
Choose the below operation according to the PIN output format of your reader
.
Remarks: 4 means 4 bits, 8 means 8 bits, 8 10 means 10 digits virtual number.
-
Add PIN Users:
To add PIN users, after enter into programming mode on the device, PIN(s) can be input/ added on either the device or the external Keypad Reader. -
Delete PIN Users: the same way as add users.
WIEGAND READER MODE
The device can work as Standard Wiegand Reader, connected to the third party Controller —7 8#
Connection Diagram
Notes:
- When set into Wiegand Reader mode, nearly all settings in Controller Mode will become invalid, and Yellow wire will be redefined as below:
- Yellow wire: Buzzer control
- If you need to connect Yellow wire:
When the input voltage for Buzzer is low, it will sound.
Set Wiegand Output Formats
Please set the Wiegand output formats of Reader according to the Wiegand input
formats of the Controller.
Note: For connecting Wiegand controller with 32, 40 bits input, need disable parity bits.
ADVANCED APPLICATION
Collection Card Mode
After this mode turned on, all cards can open the lock. At the same time, the
card is added to the device.
Reset the WiFi (After resetting, the device will be removed in APP )
Video Intercom Access