KICHLER 52492BNB 12 Light 17 inch Brushed Natural Brass Chandelier Ceiling Light Instruction Manual
- October 30, 2023
- KICHLER
Table of Contents
KICHLER 52492BNB 12 Light 17 inch Brushed Natural Brass Chandelier
Ceiling Light
Product Information
The product is a lighting fixture that comes with a main body [A], candle
sleeves [B], safety cables [D], wood screws [E] drywall anchors [F], mounting
plate [G], mounting screws [H], plate
mounting screws [I], support cables [J], power cables [K], cable strain relief
[L], canopy [M], and sockets [N]. The product requires a 3/16 (4.76 mm)
diameter drill bit, which is not supplied with the product. The fixture can be
installed on an outlet box, which is not supplied with the product.
Product Usage Instructions
- Pass the supply wires from the outlet box down through the hole in the center of the mounting plate [G] and attach the mounting plate to the outlet box [C] using the plate mounting screws [I]. The mounting plate can be adjusted to suit the position of the fixture.
- Using the mounting plate as a template, mark the positions for the two drywall anchors [F], one on each side of the mounting plate. Carefully unscrew the plate mounting screws and remove the mounting plate.
- Use a 3/16 (4.76 mm) diameter drill bit to drill drywall anchor holes into the ceiling. Tap two drywall anchors into drilled holes, one on each side of the mounting plate.
- Pass the supply wires from the outlet box down through the hole in the center of the mounting plate and re-attach the mounting plate to the outlet box using the plate mounting screws.
- Secure the mounting plate to drywall anchors using the two wood screws [E].
- Adjust each support cable [J] to the desired length. To shorten the cable, push up the cable at the cable strain relief [L] attached to the canopy [M] and push the cable into the canopy. To lengthen the cable, push up on the cable strain relief and gently pull down on the cable to the desired length. Adjust the length of the power wire [K] simultaneously by gently pulling the wire out of the canopy or pushing the wire into the canopy. Cut fixture wires a minimum of 20 inches from the top edge of the canopy.
- Attach the safety cables [D] to the mounting plate or to the inside of the outlet box and secure them into place to prevent damage to the wires during wiring.
- Follow the grounding instructions based on whether the fixture has a mounting plate with a hole and two raised dimples or a cupped washer provided.
- Make wire connections based on the chart provided. Connect black or red supply wire to black and white supply wire to white. Use wire connectors to connect fixture ground wire to outlet box ground wire.
FIXTURE DIAGRAM
PARTS LIST
- Main Body
- Candle Sleeve Main Body
- Outlet Box (Not . Supplied)
- Safety Cable
- Wood Screw
- Drywall Anchor
- Mounting Plate
- Mounting Screw
- Plate Mounting
- Support Cable
- Power Cable
- Cable Strain Relief
- Canopy
- Sockets
INSTALLATION INSTRUCTIONS
-
Pass supply wires from the outlet box down through hole in center of the mounting plate and attach the mounting plate[G] to the outlet box[C] using the plate mounting screws[I]. The mounting plate can be adjusted to suit the position of the fixture.
-
Using the mounting plate as a template, mark the positions for the two (2) drywall anchors[F], one on each side of the mounting plate. Carefully unscrew the plate mounting screws and remove plate mounting screws and mounting plate.
-
Use a 3/16″ (4.76 mm) diameter drill bit (not supplied) to drill drywall anchor holes into ceiling. Tap two (2) drywall anchors into drilled holes, one of each side of the mounting plate.
-
Pass supply wires from the outlet box down through hole in the center of the mounting plate and re-attach the mounting plate[G] to outlet box[C] using the plate mounting screws[I].
-
Secure the mounting plate to drywall anchors using the two (2) wood screws[E].
-
Adjust each support cable[J] to the desired length. To shorten the cable, push up on the cable at the cable strain relief[L] attached to the canopy[M] and push cable into canopy. To lengthen the cable, push up on the cable strain relief and gently pull down on the cable to the desired length. Adjust the length of the power wire[K] simultaneously by gently pulling wire out of canopy or pushing wire into canopy.
-
Cut fixture wires a MINIMUM of 20 inches from the top edge of canopy.
-
Attach the safety cables[D] to the mounting plate or to the inside of the outlet box and secure into place to prevent damage to the wires during wiring.
-
Grounding instructions: (See Illus. a or b).
- On fixtures where mounting plate is provided with a hole and two raised dimples, wrap ground wire from outlet box around green ground screw, and thread into hole.
- On fixtures where a cupped washer is provided, attach ground wire from outlet box under cupped washer and green ground screw, and thread into mounting plate
If fixture is provided with ground wire, connect fixture ground wire to outlet box ground wire with wire connector after following the above steps. Never connect ground wire to black or white power supply wire
-
Note When parallel wire (SPT 1 & SPT 2) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (See illus.)
-
Raise canopy to ceiling, carefully aligning mounting screw holes in sides of canopy with threaded holes in sides of mounting plate. NOTE Make sure wires do not get pinched between mounting plate and canopy or canopy and ceiling
-
While holding canopy in place, thread in four (4) mounting screws[H] into holes to secure canopy. Tighten to secure
-
Slide candle sleeves[B] down over the sockets[N] of the main body[A]. Repeat for all sockets.
-
Install the recommended bulbs (not supplied).
For warranty information please visit kichler.com/warranty
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>