KICHLER 52495BNB Florence 6-Light Brushed Natural Brass Traditional Candlestick Dining Room Linear Chandelier Instruction Manual

October 30, 2023
KICHLER

KICHLER 52495BNB Florence 6-Light Brushed Natural Brass Traditional Candlestick Dining Room Linear Chandelier

KICHLER 52495BNB Florence 6-Light Brushed Natural Brass Traditional
Candlestick Dining Room Linear Chandelier

We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST

FIXTURE DIAGRAM

Fixture Diagram 

PARTS LIST

[A] Socket (Qty. 6)
[B] Safety Cable (attached to Canopy)
[C] Outlet Box (not supplied)
[D] Canopy
[E] [Strap Mounting Screw (Qty. 2)
[F] Candle Sleeve (Qty. 6)
[G] Mounting Strap [H] Loop (attached to Canopy Qty. 2)
[I] Lock-Up Knob (Qty. 2)
[J] Locking Chain Link (Qty. 4)
[K] Chain (Qty. 2)
[L] Decorative Loop (Qty. 2)
[M] 5.5 inch Threaded Tube (Qty. 2)
[N] Decorative Tube (Qty. 2)
[O] Finial (Qty. 2)
[P] Connecting Tube (Qty. 2)
[Q] Lower Connection (Qty. 2)
[R] Coupling (Qty. 2)
[S] Mounting Screw (Qty. 2)
[T] Lock Washer (Qty. 2)

CAUTIONS

CAUTION – RISK OF SHOCK:
Disconnect Power at the main circuit breaker panel or main fuse box before starting and during the installation.

WARNING:

  1. This fixture is intended for installation in accordance with the National
    Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended.
    Failure to adhere to these codes and instructions may result in serious injury and/or property damage and will void the warranty.

CLEANING:

  • Always be certain that electric current is turned off before cleaning.
  • Only a soft damp cloth should be used. Harsh cleaning products may damage the finish.

INSTALLATION INSTRUCTIONS

  1. On side of fixture with fixture wires, thread connecting tube [P] onto coupling [R]. Tighten to secure.

  2. On side of fixture without fixture wires, thread other connecting tube [P] onto other coupling [R]. Tighten to secure.

  3. Carefully slip a candle sleeve [F] over a socket [A] and push sleeve completely down over socket until it is seated against the socket base. Repeat for remaining candle sleeves and sockets.

  4. Attach one locking chain link [J] to each decorative loop [L].
    NOTE: Locking chain links can be opened and closed by threading the nut on and off link end.

  5. To each locking chain link [J], attach one chain [K].

  6. Attach remaining locking chain links to the free ends of each chain.

  7. Attach these top locking chain links [J] to loops [H].

  8. After all locking chain links are closed, on side of fixture with fixture wires, weave fixture wires through links of chain no more than 3 inches apart. Pass fixture wires through loop [H] and into canopy [D].

  9. Find the appropriate threaded holes on mounting strap [G] that align with hole distance in canopy [D]. Screw mounting screws [S] into threaded holes starting from the outlet box side.

  10. Attach mounting strap to outlet box [C] using the strap mounting screws [E]. Mounting strap can be adjusted to suit position of fixture.

  11. Loop safety cable [B] over the mounting strap and attach to the mounting strap or to the inside of the outlet box to secure in place and prevent damage to the wires during wiring.

  12. Grounding instructions: (See Illus. a or b).
    a. On fixtures where mounting strap is provided with a hole and two raised dimples, wrap ground wire from outlet box around green ground screw, and thread into hole.
    b. On fixtures where a cupped washer is provided, attach ground wire from outlet box under cupped washer and green ground screw, and thread into mounting strap.
    If fixture is provided with ground wire, connect fixture ground wire to outlet box ground wire with wire connector after following the above steps. Never connect ground wire to black or white power supply wires.

  13. Make wire connections. Reference chart below for correct connections and wire accordingly.
    Connect Black or Red Supply Wire to:|

Connect White Supply Wire to:

---|---

Black

| White

*Parallel cord (round & smooth)

| *Parallel cord (square & ridged)
Clear, Brown, Gold or Black without Tracer|

Clear, Brown, Gold or Black with Tracer

Insulated wire (other than green) with copper conductor|

Insulated wire (other than green) with silver conductor

*Note: When parallel wire (SPT 1 & SPT 2) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (See illus.)| Neutral Wire
14. Raise canopy to ceiling, carefully passing mounting screws through mounting screw holes in canopy.
NOTE: Make sure wires do not get pinched between mounting strap and canopy or canopy and ceiling.

  1. Secure canopy to ceiling using lock washers [T] and lock-up knobs [I]. Tighten lock-up knobs to secure.
  2. Insert recommended bulbs (not supplied).
  3. Thread a 5.5 inch threaded tube [M] into a lower connection [Q]. Tighten to secure. Repeat on other side of fixture.
  4. Slip a decorative tube [N] over an installed 5.5 inch threaded tube. While holding decorative tube in place up against the fixture, thread on a finial [O] until finial is seated against bottom of decorative tube. Tighten to secure. Repeat on other side of fixture.

For warranty information please visit: kichler.com/warranty

Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

KICHLER User Manuals

Related Manuals