LARK 83075 5 Light Chandelier Instruction Manual

June 3, 2024
LARK

LARK-LOGO

LARK 83075 5 Light Chandelier

LARK-83075 5-Light-Chandelier-PRODUCT IMG

Mounting Instructions

Start here

  1. Find a clear area in which you can work.
  2. Unpack the fixture and glass from the carton.
  3. Carefully review instructions prior to assembly.

Stem Install

  1. Determine the desired height at which the pendant will be installed
  2. The fixture is supplied with assorted stem sizes. Determine what combination of stems are needed to achieve the desired length
  3. Slip stems over wire and thread first stem onto top of the pendent, the longest stem first. Repeat the process until all required stems are threaded together.

Fixture Mounting

LARK-83075 5-Light-Chandelier-FIG-
\(2\)

  1. Prepare mounting strap (B) for mounting by installing screws (A) in mounting plate (B) – see Drawing 2.
    Be sure the holes into which the screws are threaded match spacing of holes (C) in the canopy (4).

  2. Attach mounting plate (B) to junction box (J), using screws (G) NOT provided and slip supply wires through the large center hole in mounting plate (B).

  3. Now adjust screws (A) so the screw will extend 3/16” past the face of the canopy when the canopy is flush against the ceiling. after the screws are adjusted tighten hex nut (H) to lock the screws in place.

  4. Make electrical connections from supply wire to fixture lead wires. Refer to the instruction sheet (IS 18) and follow all instructions to make all necessary wiring connections.

  5. Hold the fixture towards the ceiling and slip mounting holes (C) in the canopy (4) over screws (A).

  6. Secure the canopy by threading barrel knobs (D) onto screws (A).

SAFETY WARNING : READ WIRING AND GROUNDING INSTRUC-TIONS (FRIS-18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRINGIS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

SAFETY WARNING : READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING ISs REQUIRED, CONSULTA QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS

Wiring instructions

Indoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B)
    with appropriately sized twist on connector see Drawings 1 or 2.

  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).

  3. Please refer to the grounding instructions below to complete all electrical connections

Outdoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector — see Drawings 2 or 3.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Cover open end of connectors with silicone sealant to form a watertight seal.
  4. If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.
  5. Please refer to the grounding instructions below to complete all electrical connections

Grounding instructions

Flush Mount Fixtures

For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M) with the ground screw (S) – see Drawing 1.
Note : On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.

Chain Hung Fixtures

Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Drawing 2.

Post-Mount Fixtures

Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.

LARK 33000 PIN OAK PARKWAY, AVON LAKE, OH 44012 LarkLiving.com