LEDISONS LDM30-02-WIT LED Dimmer Installation Guide
- June 3, 2024
- LEDISONS
Table of Contents
LEDISONS LDM30-02-WIT LED Dimmer
INSTALLATION
COMPONENTS
- Dimmer,
- Frame,
- Central plate,
- Adjusting knob,
- Screw terminals,
- Screwing tool,
- Mounting ring,
- Connector,
- Thickening button.
8 & 9 are only required if the dimmer is used in combination with cover frames from certain brands.
CONNECTION DIAGRAM
DIMMER
- Connect the dimmer according to the diagram above.
- Mount the dimmer in the accessory socket.
- Mount the frame and the central plate.
- Attach the adjusting knob.
TWO-WAY SWITCH
- Connect the dimmer according to the diagram above.
- Connect the switch according to the diagram.
- Mount the dimmer in the accessory socket.
- Mount the frame and the central plate.
- Attach the adjusting knob.
TECHNICAL DATA
Main voltage & frequency | 220-240V ~ 50Hz |
---|---|
Rating | 2-100W: dimmable LED lamps. 10-200W: Incandescent, high-voltage |
halogen lamps and electronic step-down converters for extra low-voltage
incandescent lamps.
Compatible loads| Dimmable LED lighting with compatible electronic
transformers, incandescent lighting, MV halogen lamps, LV halogen lamps with
electronic transformers.
Operating temperature| 0°C – 35°C
Operating humidity| 10 – 90 % R.H.
Assembly centers| 82 mm EU sample plate.
Dimming technology| Phase cut-off.
Inclusive| Soft locking on activation / short circuit protection / electronic
over-temperature protection.
Safety information
Electrical equipment may only be installed and fitted by electrically skilled
persons.
Failure to observe the instructions may cause damage to the device and result
in fire and other hazards.
Danger of electric shock. Always disconnect before carrying out work on the
device or load. At the same time, take into account all circuit breakers that
supply dangerous voltage to the device or load.
Device is nogs suitable for disconnection from supply voltage. The load is not
electrically isolated from the mains even when the device is switched off.
These instructions are an integral part of the product, and must remain with
the end customer.
The dimmer shall be protected by a 10A maximum miniature circuit breaker,
which is special use with this dimmer.
Electrical shock when live parts are touched. electrical shocks can be fatal.
Before carrying out work on the device or load, disconnect all the
corresponding circuit breakers. Cover up live parts in the working
environment.
When the dimmer switches off the load and turns it on after some time,
overheating protection has tripped, too much load is connected or the product
is not installation according to this guide. If the dimmer keeps being off,
please check if the short-circuit has tripped and eliminate the short-circuit.
We reserve the right to make technical and formal changes to the product in
the interest of technical progress. We provide a warranty as provided for by
law.
Please send the unit postage-free with a description of the defect to our
address if any defects.
Flickering of the connected lamps due to undershoot of the specified minimum
load or through centralized pulses from the power stations, does not represent
any defect in the device.
The light sources could blink if the dimmer is turned on too fast after
turning off.