CCH YPLA-08C Portable air conditioner User Manual

June 5, 2024
CCH

CCH YPLA-08C Portable air conditioner

CCH YPLA-08C Portable air conditioner product

Thank you for selecting this high quality air conditioner. Please be sure to read this manual carefully before using it.

User Agreement

Icons appearing in this manual have the following meaning:

  • This type of operation is forbidden for the health and safety of you and your family .
  • The following events must be performed for the health and safety of you and your family

Precautions

In order to ensure the machine’s service life, environment is recommended for (7-35) C

The unit is designed for household d use ONLY .
CCH YPLA-08C Portable air conditioner 01

Please use the unit indoors, keep it in the dry environment, and do not use it Outdoors.CCH YPLA-08C Portable air conditioner 03

Do not place any objects around the unit which can impede the interchange of air performed by the unit.CCH YPLA-08C Portable air conditioner
01

Do not place any heavy objects on the unit which can damage the unit.CCH
YPLA-08C Portable air conditioner 04

Do not operate the unit using we hands. Do not use the unit humid environmentCCH YPLA-08C Portable air conditioner 04

Always use a soft cloth to dean the unit, and do not use the wax, thinner or irritative detergent.CCH YPLA-08C Portable air conditioner
04

Please clean the filter screen frequently, and cleaning it at least once two weeks is advisable.CCH YPLA-08C Portable air conditioner
04

Do not drink the condensation water discharged from the unit for your health.CCH YPLA-08C Portable air conditioner 04

Always turn the unit off and unplug the power cord when the unit is intended for no use for along timeCCH YPLA-08C Portable air conditioner
04

Non-professional people may not attempt to dismantle or repair the unit.CCH
YPLA-08C Portable air conditioner 04

Important Safety Tips

The appliance shall be installed in accordance with national wiring regulations If the supply cord is damaged, it must be replaced by the manufacturer, its service get or similarly qualified persons in order to avoid a hazard.

Do not damage the power cord, and do not use a damaged power cord or a power cord or power cord plug and do not insert the power cord into a loose plug receptacle.CCH YPLA-08C Portable air conditioner 04

Do not use nonservice able power cord or power cord plug, and do not insert the power cord into a loose plug receptacle. of unknown type. Before use, always ensure the electric voltage used is satisfactory.CCH YPLA-08C
Portable air conditioner 14

Do not attempt to rework or extend the power cord.CCH YPLA-08C Portable air
conditioner 04

When using the unit, a grounding receptacle is advisable.CCH YPLA-08C
Portable air conditioner 14

Do not insert or pull out the power cord plug using wet hands, because it may raze the risk of electric shock.CCH YPLA-08C Portable air conditioner
13

When pulling out the power cord, always grip the plug, and do not pull the power cord.CCH YPLA-08C Portable air conditioner 14

Do not stay or stop the unit by inserting or pulling out the power cord plug.CCH YPLA-08C Portable air conditioner 18

Always turn off the unit before pulling out the power cord plug.CCH YPLA-08C
Portable air conditioner 18

Do not share a plug receptacle with a number of large power consumersCCH
YPLA-08C Portable air conditioner 18

Always keep the unit away from heat, and keep out of the direct sun.CCH
YPLA-08C Portable air conditioner 18

Always immediately turn off and unplug the unit for trouble shooting if the unit emits a strong noise, odor or smo9.CCH YPLA-08C Portable air
conditioner 18

Do not place any heavy objects on the power cord in case of the risk of electric shock caused by the power cord damage.CCH YPLA-08C Portable air
conditioner 18

Do not insert your fingers or hard objects into the louvers at the air outlet.CCH YPLA-08C Portable air conditioner 18

Do not allow wear to enter the electrical parts of the unit.CCH YPLA-08C
Portable air conditioner 25

If water has entered the inside of the unit, always turn off and unplug the unit before contacting qualified service technician for troubleshooting.CCH
YPLA-08C Portable air conditioner 18

Always turn off the unit and unplug the power cord before you wipe, dean, move the unit or replace its partsCCH YPLA-08C Portable air conditioner
26

When gas leaks, always open the window for good ventilation before rerunning the unit.CCH YPLA-08C Portable air conditioner 26

Do not let children or any other special populations touch the unit in case of injury to them. If they are required to operate the nit, their operations must be subject to adult supervision. For European market: This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. For non-European market: This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.CCH YPLA-08C
Portable air conditioner 28

Special Warning

Always place the unit on a level ground, and keep it vertically to ensure the normally working of its compressor.CCH YPLA-08C Portable air conditioner
29

Always maintain at least 5Ucm durance space around the unit, and keep unobstructed  the are inlet or outlet grilles.CCH YPLA-08C Portable air
conditioner 30

Never use gasoline or other flammable liquid near the unit.CCH YPLA-08C
Portable air conditioner 30

Do not use sprays or other solvents which can cause plastic deformation or even damage the electrical parts of the unit.CCH YPLA-08C Portable air
conditioner 30

Product Description

Name of Main Components and Parts

CCH YPLA-08C Portable air conditioner 30 CCH
YPLA-08C Portable air conditioner 30 CCH
YPLA-08C Portable air conditioner 30

  1. Handle
  2. Air Inlet (Right)
  3. Control Panel
  4. Louvers
  5. Casters
  6. Remote  Control
  7. Air Inlet (Left)
  8. Air Outlet
  9. Drain
  10. Drain Port
  11. filter Handle
  12. Venting kit
  13. Window kit
Control panel and Remote Control

CCH YPLA-08C Portable air conditioner 37 CCH
YPLA-08C Portable air conditioner 37

  1. Power Button
    Press the button to turn on/off the unit.

  2. Mode Selection Button
    Press the button repeatedly to cycle between the different modes:

  3. Cooling, Dehumidify, Fan.
    Temperature/Time Setting Buttons (Up and Down) When the unit is running in Air Conditioner mode, press the buttons to increase or decrease the preset temperature. In Timer mode, press the buttons to set the desired time for the unit to automatically turn on/off. Pressing the Setting button (Up) and the Setting button (Down) simultaneously will change the temperature select between °F and 0 C.

  4. Fan Speed Selection Button
    Press the button to cycle through high and low fan speeds.

  5. Timer Function Button
    In standby mode, press the button to set the desired time for the unit to automatically turn on. In power-on mode, press the button to set the desired time for the unit to automatically turn off.

  6. Temperature/Time Display Window
    The window is used to display the preset temperature and time .

  7. Remote Control Signal Receptor
    The receptor is designed to receive the signal transmitted from the remote control.

  8. Celsius/Fahrenheit Conversion Button
    Press the button to realize the display conversion between Fahrenheit and Celsius.

  9. Sleep Button
    Under cooling mode ,press the button to select sleep mode

Product Usage

Placement and Installation

Placement

  • Place the unit on the horizontal floor near a window.
  • To keep good air circulation and achieve the optimum performance of the unit, maintain at least 50cm durance escapes around the unit.

CCH YPLA-08C Portable air conditioner 37

BEST INSTALLATION

CCH YPLA-08C Portable air conditioner 37

Installation

CCH-YPLA-08C-Portable-air-conditioner-38

Step 1:CCH YPLA-08C Portable air conditioner 42
Clip-fixture Type

  1. Measure window size;
  2. Adjust Length of the plate according to window size;
  3. Lock the plate

CCH YPLA-08C Portable air conditioner 42

Step 2:CCH YPLA-08C Portable air conditioner 42 Fix the plate to window

Step 3:CCH YPLA-08C Portable air conditioner 42

Swirl the exhaust pipe assembly ( exhaust fitting end) into the rear panel outlet (counterclockwise).

Step 4:CCH YPLA-08C Portable air conditioner 42CCH
YPLA-08C Portable air conditioner 42 Insert the venting kit ( exhauster) into the window kit, and faster it with screws.

Overall Effect Drawing After Assembling

Wrong Installation

CCH YPLA-08C Portable air conditioner 51

  • It is important for the exhaust hose to keep good ventilation.
  • The wrong installation will affect the normal working of the unit.
  • Avoid a sharp bend in the exhaust hose while installing.
  • Make sure the air flows smoothly in the hose.

Warning:
The length of the exhaust hose has been specially designed for this type of unit. Do not use an extension or exchange of a different hose as that may lead to a malfunction.
Attention:
The length of the exhaust hose can expand up to 1500mm, and please shorten its length as best as you can when you mount it. In the installation process, keep the exhaust hose as straight as possible.

Remote Control

CCH YPLA-08C Portable air conditioner 51Before using the remote control, please correctly install the batteries. The specific steps are as follows

  • Remove the battery cover on the back of the remote control.
  • Insert two new AAA DC1.5V batteries with “” and “-“pointing in the proper direction.
  • Snap the battery cover into place on the back of the remote control.

ATTENTION

  1. Only AAA DC1.5V batteries can be used for the remote control of the unit. Never use rechargeable batteries or other types of batteries.
  2. The two batteries should be replaced at the same time, and do not mix new and old batteries.
  3. Remove the batteries if the remote control is not in use for an extended time.

Warning:

  1. If you discover the battery leaks, do not use it.

  2. The chemical substances in batteries may cause burnt or other health hazards. If the liquid accidentally flows down to your skin or clothing, please immediately rinse with clear water.
    If you accidentally drink it, please immediately rinse mouth with clear water, and then seek for medical attention.

  3. Make sure that the unit is upright position for 2 hours before turning on for first time.

CCH YPLA-08C Portable air conditioner 53

Operating Procedure

Air Conditioner Mode
  • Plug the power cord to a power socket and tum on the unit, the unit will be in Air Conditioner mode directly or by pressing the mode button, and at this moment the Air Conditioner mode icon lights up.
  • Press the Setting button (Up) or the Setting button (Down) to change the preset temperature (ranging from l6°C to 30°C)(60°F to 86°F).
  • Press the FAN button to cycle through high and low fan speeds.
Fan Mode
  • Press the Mode button or select FAN mode by using the remote control until the fan mode icon lights up.
  • Press the FAN button to cycle through high and low fan speeds.
  • The temperature cannot be set.
Dehumidification Mode
  • When pressing mode key or choosing dehumidification mode by pressing the remote controller, the dehumidification indicator lamp lights up.
  • After entering the dehumidification mode, if room tempearture2:l 7 C ( 62 1 ), the compressor is ON.
  • Then control as follows: when room temperature ~15 C (59 “F ), the compressor is OFF; when temperature increases to room temperature2:l 7 C, the compressor is started again (in order to protect the compressor, it will be restarted 3min. later).
  • In dehumidification mode, the fan is defaulted to run at low speed, and wind speed can’t be adjusted.
  • Temperature can’t be set. (Note: when use dehumidify function, should remove exit pipe components, otherwise, it will cause worse dehumidify performance, and appear “FL” water full alarm)

Timer Mode

  • In standby mode, press the timer button to set the desired time for the unit to automatically turn on. Press the Setting button (Up) or the Setting button (Down) to set the desired time for the unit to automatically tum on (l-24 hours) until the timer indicating lamp lights up.
  • In power-on mode, press the timer button to set the desired time for the unit to automatically turn off. Press the Setting button (Up) or the Setting button (Down) to set the desired time for the unit to automatically turn off (1-24 hours) until the timer indicating lamp lights up.

Sleep Mode

  • Under Cooling mode , press sleep button on the remote control (or press unit button Timer+ Down at the same time) to select sleep mode , the fan run at low speed, the wind speed can’t be adjusted. Change the mode or press sleep button on the remote control again (or press unit button Timer + Down at the same time ) to stop this mode.

Cleaning and Maintenance

Water Drainage

This product has a self-evaporative system. The condensing water will recycle to cool the condenser. This water-cooled mode not only can improve cooling efficiency, but also save energy.
If the water basin within the unit is full, “FL” will flash on the display screen, accompanying with aural warning. Meanwhile the compressor will automatically stop working. At this moment the water in the basin should be drained out, and the specific steps are as follows:

  1. Remove the power cord plug and take down the venting kit.
  2. Move the unit to a good place.
  3. Remove the drain plug, and exhaust the water within the unit.
  4. Fasten the drain plug once again .
  5. Remount the venting kit and turn on the unit

Maintenance

Note: To avoid electric shock, please turn off and unplug the unit prior to maintenance.
Clean the unit housing)

  1. Unplug the unit before cleaning.
  2. Use a damp soft cloth to clean the surface. Do not use a chemical solvent like benzene, alcohol or gasoline, etc. as it may damage the surface or even the unit.
  3. Do not let water splash into the unit.CCH YPLA-08C Portable air conditioner 55

Air Filter

It is recommended to clean the air filter once every two weeks, and if the indoor air quality is poor, the cleaning frequency should rise appropriately. Because the air filter is blocked with a dust, the airflow volume may reduce. Specific cleaning steps are as follows:

  1. As shown in the diagram below, first remove the air-inlet grille, and then remove the air filter.
  2. Use a vacuum cleaner to vacuum off all lint and dander from filter.
  3. Wash the air filter by immersing it into clear water or warm water (Ca. 40°C) with a neutral detergent. Then place it in a cool place, and dry it thoroughly.
  4. Slide the filter back into place after it is thoroughly dried.
  5. Restart the unit, and the unit will run normally.CCH YPLA-08C Portable air conditioner 55

If the air filter is not too dirty, use a dust catcher to remove the dust from its surface.

If the air filter is very dirty, use clear water or warm water (Ca. 21-0’C) to wash it.

Note :

  • Do not use too hot water (preferential temperature is about 40 •c) or irritative detergents (like alcohol, gasoline or benzene) to clean the air filter.
  • To avoid the deformation of air filter, the cleaned air filter must be away from heat, and it should be kept in a dry place and dry naturally.
  • Do not run the unit without the air filter.
Seasonal Maintenance

If the unit is not intended for use for a long time, please maintain it according to the following steps:

  • Remove the drain plug for water drainage.
  • Run the unit for 2 hours in FAN mode until the inside of the unit is blow-dried.
  • Turn off the unit and disconnect the plug from the power supply.
  • Clean the air filter and remount it.
  • Dismantle the accessories including the exhaust hose and keep them safely.
  • Take the batteries out of the remote control.
  • Wrap the unit with a plastic bag and keep it in a cool and dry place.
  • If possible store unit in its original box with the packing provided.

When you start using the unit after it has not been used for a long time, please note the following points:

  • Make sure whether the drain plug and air filter are installed.
  • Inspect the power cord for signs of damage before use. If the power cord is damaged, do not use it.
  • Reinstall the batteries in the remote control.
  • Reinstall all other parts in accordance with the mounting list.

Common Troubles and Diagnosis

Intelligent Diagnosis of Troubles

CCH-YPLA-08C-Portable-air-conditioner-53

Trouble Shooting

The following table lists some common troubles with the unit (Portable Air Conditioner KY-20/LA) and solutions to them. When the unit runs abnormally, the following table will help you to detect some simple faults and fix them, but if they still last, please contact a qualified service technician.

CCH-YPLA-08C-Portable-air-conditioner-54

Some Technical Parameters of the Unit

Fuse Protector Parameters

Specification: cD 5 X 20mm
Electric Voltage: 250VAC
Electric Current: 3.15A

Overall Dimension of the Unit

CCH YPLA-08C Portable air conditioner 60

The above technical parameters may be subject to modification without further notice

SERVICE CENTER:
1850 S Carlos Ave, Unit2
Ontario, CA 91761
Hours : 8: 30AM-5: 00PM PST

TO OBTAIN WARRANTY SERVICE:
Contact CCH Technical Support
TolI free: 1-844-909-7300
Email:[email protected]
From 8:30AM to 5:00PM Monday through Friday Pacific Time.

WARRANTY PERIOD:
Labor: 1 Year from the Date of Purchase.
Parts: 1 Year from the Date of Purchase.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CCH User Manuals