Warning
Technical Parameters
CCT | 2700-6500K | Power Factor | > 0.95 |
---|
Working
Temperature
| -40’C -60’C| Working Life| 50,000 hours
Beam Angle
| 10· / 30• /60 • /90′ /12 o·| Input Voltage| AC 100-240V 277V~, 50/60Hz
LAMP
165LM /W ± 5%
(60″/90’/120′)
LUMINOUS
15 SLM /W ± 5% (30 ‘)
FLUX| 165LM /W ± 5%
(60″/90’/120′)
LUMINOUS
15 SLM /W ± 5% (30 ‘)
FLUX
120LM/W±5%(10’)| CRI| IP66
IP Grade| Ra>70/80
Lamp Power| Lamp Size(mm)| Lamp Luminous Flux| Net Weight(kg)
---|---|---|---
480W
|
536x165x579
|
84,000LM
|
12.0kg±5%
720W
|
691x202x579
|
126,800LM
|
16.0kg±5%
960W
|
846x202x579
|
168,000LM
|
19.6kg±5%
1200W| 1001x277x579|
210,000LM
| 24.0kg±5%
1440W| 1156x277x579| 252,200LM| 28.0kg±5%
Trouble Shooting
- Please don’t disassemble light without being authorized staff only.
- Please report us the abnormality in time.
Problem | Possible Cause | Solution |
---|
LEDs stop working
| The power line/plug properly connected.| Reconnect the power cabla/plug.
Power failure.| Ch eek the It.
Fault with LED driver.| Replace with new driver.
Damage to LED chips.| Replace with new LEDs board.
LEDs flash on and off
| The output of the driver is abnormal.| Replace with new driver.
The LED chip breaks down.| Replace with new LED board.
Voltage instability.| Powar-off and check tha power supply.
Installation Steps
140° Adjustment
- Use No.6 wrench to loosen the Hexagon screws.
- Adjustment module direction.
- Tighten the screws.
360° Adjustment
- Use No.Z.5 wrench to loosen the set screw.
- Adjustment module direction.
- Tighten the screws.
Tips: Hole 123 must fix with screws.