SFA SaniPro XR Sump Pump Instruction Manual

June 3, 2024
SFA

SaniPro XR Sump Pump
Instruction ManualSFA SaniPro XR Sump Pump SANIPRO® XR

INSTALLATION INSTRUCTIONS

SFA SaniPro XR Sump Pump - Figure 1SFA SaniPro XR
Sump Pump - Figure 2SFA SaniPro XR Sump Pump - Figure
3SFA SaniPro XR Sump Pump - Figure 4SFA SaniPro XR
Sump Pump - Figure 5

UNITED KINGDOM
SANIFLO Ltd.,
Howard House, The Runway
South Ruislip Middx.,
HA4 6 SE
Tel. +44 208 842 0033/4040
Fax +44 208 842 1671

SERVICE HELPLINES
United Kingdom
08457 650011 (Call from a land line)
TEL
+31 475 487100
08-744 15 18

IMPORTANT ADDITIONAL INFORMATION

DESCRIPTION
This macerator is (manufactured in a factory which is quality) certified to ISO 9001.
Installed and used correctly, the unit will give consistent and reliable service.
This device is not designed for persons (including children) with limited physical, sensory or mental abilities, or those with minimal experience and knowledge, unless they  are monitored and are given the necessary instructions for using the device, with the help of a person responsible for their safety.
Monitor children and make sure they do not play with the device.

APPLICATIONS
This appliance is a compact lift pump unit designed for removing waste water from a horizontal outlet toilet, shower, bidet or washbasin (*: depending on the model).
This appliance conforms to EN 12050-3 and the European standards concerning electrical safety and electromagnetic compatibility.

INSTALLATION
The unit should be accessible for possible service.
The fitting and working of your appliance must meet local regulations and the EN 12056-4 standard.
To optimise the latest technical develop­ments concerning soundproofing incorpo­rated into this unit, it is important to:

  • position the WC pan so that it is not in contact with a partition or wall of the room
  • place the WC pan on a perfectly level surface to ensure that the resilient mounts are fully efficient
  • fix the discharge pipe correctly, with distances of not more than one metre between the fastenings.

CONNECTION TO THE ELECTRICAL SUPPLY
The electrical installation should
be carried out by a qualified person.
The unit requires a 220/240V single phase AC 50 Hz supply (UK specification).
The power supply circuit of the ap­ pliance must be earthed (Class I) and protected by a GFCI high sensitivity (30mA). Warning: Ensure the electri­ city is turned OFF at the main switch board before wiring to connector.
All wiring must conform to BS7671, 1992 requirements for electrical installations. Do not connect the unit to a conventional plug and socket. It must be wired into a fused, unstitched, fixed wiring connector fitted with a 5 amp fuse. The wires in the mains lead are coloured in accordance with the following code:
Brown – Live
Blue – Neutral
Green/Yellow – Earth
The connection must be used exclusively to power the device.
All work on cable, pressure chamber and motor should only be carried out by a qualified Saniflo servicing agent, as special tools are required. Please do not cut/shorten the  electrical supply cable which can make it very difficult to remove in the event of a service requirement.

COMMISSIONING THE UNIT
Flush the WC checking that all seals, and connections are watertight.
Check both the discharge pipework from the unit and the other sanitary appliances connections. Check the watertightness of connections to sanitary appliances: toilet, shower, bidet or washbasin (*:depending on the model).

MAINTENANCE

WARNING !!! In the event of prolonged absence it is essential to turn off the water supply to protect the installation against sub zero temperatures.
CARE OF YOUR UNIT
In order to remove scale and clean the macerator and the bowl, use the SANIFLO
Cleanser/Descalent.

  • Disconnect the macerator power supply,
  • Pour an amount of cleanser into the pan
  • Leave it to stand for 1 or 2 hours,
  • Re-connect the macerator power supply,
  • Rinse by operating the flushing system twice.

Carry out the operation once every 3 months on average, but the frequency may need to be changed depending on the hardness of the water.

FAULT FINDING/REMEDIES

IN ALL CASES, YOU MUST DISCONNECT THE MACERATOR FROM THE POWER SUPPLY

GUARANTEE
2 years guarantee as from its date of purchase subject to correct installation and correct use.
Only the disposal of toilet paper, faecal matter, and waste water will be under guarantee. Any damage due to foreign bodies such as cotton, condoms, sanitary towels, wet wipes, food, hair, metal, wood or plastic objects, will not be under guarantee. Solvents, acids and other chemicals can also cause damage to the unit, and will invalidate the guarantee.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals