SFA SV 1X SANIVITE evacuation pump Installation Guide

June 5, 2024
SFA

SFA SV 1X SANIVITE evacuation pump

SFA-SV-1X-SANIVITE-evacuation-pump-
PRODUCT

INSTALLATION INSTRUCTIONS

SFA-SV-1X-SANIVITE-evacuation-pump-
FIG-1

SFA-SV-1X-SANIVITE-evacuation-pump-FIG-2

SFA-SV-1X-SANIVITE-evacuation-pump-FIG-3

SFA-SV-1X-SANIVITE-evacuation-pump-FIG-4

SFA-SV-1X-SANIVITE-evacuation-pump-FIG-5

UNITED KINGDOM

  • SANIFLO Ltd.,
  • Howard House, The Runway
  • South Ruislip Middx.,
  • HA4 6 SE
  • Tel: +44 208 842 0033
  • Fax: +44 208 842 1671

IRELAND

  • SANIRISH Ltd
  • IDA Industrial Estate
  • Edenderry – County Offaly
  • Tel:  + 353 46 9733 102
  • Fax: + 353 46 97 33 093

Service information:  www.sfa.biz

IMPORTANT ADDITIONAL INFORMATION

DESCRIPTION

This pump is (manufactured in a factory that is quality) certified to ISO 9001, and ISO 14001. Installed and used correctly, the unit will give consistent and reliable service. This device is not designed for persons (including children) with limited physical, sensory or mental abilities, or those with minimal experience and knowledge, unless they are monitored and are given the necessary instructions for using the device, with the help of a person responsible for their safety. Monitor children and make sure they do not play with the device.

APPLICATIONS

This device is a pump designed to evacuate waste water from private dwellings (except for water coming from WCs). SANIVITE®, SANISPEED®, and SANIPUMP 2® are designed to handle the waste evacuation from a bath, kitchen sink, dishwasher, and washing machine. Its powerful pump will deal with everyday normal usage. SANISHOWER® FLAT/ SANIDOUCHE® FLAT is designed to handle the waste from a shower and handbasin. Sanispeed will take the above at a heavier duty rate of usage. SANISHOWER®/SANIPUMP 1® is designed to take the waste from a shower and handbasin. This appliance conforms to EN 12050-2 and the European standards concerning electrical safety and electromagnetic compatibility. To view the DoP (Declaration of performance) please click on the ‘Illustrations and Datasheet’ tab on each product page on our website.

INSTALLATION

  • The unit should be installed in the same space as the connected facilities and should be accessible for possible service.
  • The fitting and working of your appliance must meet local regulations and the EN 12056-4 standard.
  • To optimize the latest technical developments concerning soundproofing incorporated into this unit, it is important to:
    • fix the discharge pipe correctly, with distances of not more than one meter between the fastenings.

CONNECTION TO THE ELECTRICAL SUPPLY

The electrical installation should be carried out by a qualified person

The unit should be connected to a fully earthed electrical supply. All wiring must conform to BS7671, 1992 requirements for electrical installations. The unit requires a 220/240V single-phase AC 50 Hz supply (UK specification). Do not connect the unit to a conventional plug and socket. It must be wired into a fused, unswitched, fixed wiring connector fitted with a 5 amp fuse. The wires in the mains lead are colored in accordance with the following code:

  • Brown:  Live
  • Blue: Neutral
  • Green/Yellow: Earth

Warning: Ensure the electricity is turned OFF at the main switchboard before wiring to the connector. All work on cable, pressure chamber, and motor should only be carried out by a qualified Saniflo servicing agent, as special tools are required.

COMMISSIONING THE UNIT

Once electrical and plumbing connections have been made, check that all seals and connections are watertight. Check both the discharge pipework from the unit and the other sanitary appliances connections.

MAINTENANCE

WARNING

  • If away for a long period, we recommend that you turn off the water supply to the WC served by the unit.

CARE OF YOUR UNIT

  • In order to remove the scale and clean the pump, use a household descalent (like SANIFLO Cleanser/descalent).

FAULT FINDING / REMEDIES

IN ALL CASES, YOU MUST DISCONNECT THE PUMP FROM THE POWER SUPPLY

SYMPTOMS

  • The motor does not activate

  • The motor intermittently activates

  • The motor operates normally but does not stop or continue to run for a long time

  • The unit stops

  • Soiled water comes up into the shower basin (units with side inlets)

PROBABLE CAUSES

  • The electrical power supply is not active

  • The electrical power supply is defective

  • The motor or the control system is defective

  • The connected sanitary devices are leaking

  • The non-return valve is faulty

• The length or height of the installation is over the specification, or there are too many bends/elbows

  • The pump cover plate is occluded

  • The unit has been running for too long (thermal cut-out)

  • The shower was installed too low as compared with the pump

  • Hinged side inlet discs clogged up

0

REMEDIES

  • Restore the electrical supply

  • Check the electrical power supply

  • Otherwise, ask an approved repair agent to intervene

  • Check the installation upstream


  • Clean or replace the non-return valve

  • Check the installation




  • Otherwise, ask an approved repair agent to intervene

  • Wait for reset, then ask an approved repair agent to intervene

  • Check the installation


  • Clean the hinged discs

  • Otherwise, ask an approved repair agent to intervene

GUARANTEE

2 years guarantee from its date of purchase subject to correct installation and correct use.